Application of Fuzzy PI Control Algorithm as Stator Power Controller of a Double-Fed Induction Machine in Wind Power Generation Systems

  • Chung, Gyo-Bum (Department of Electronic and Electrical Engineering, Hongik University) ;
  • Choi, Jae-Ho (School of Electrical and Computer Engineering, Chungbuk National University)
  • 발행 : 2009.01.20

초록

This paper addresses the output control of a utility-connected double-fed induction machine (DFIM) for wind power generation systems (WPGS). DFIM has a back-to-back converter to control outputs of DFIM driven by the wind turbine for WPGS. To supply commercially the power of WPGS to the grid without any problems related to power quality, the real and reactive powers (PQ) at the stator side of DFIM are strictly controlled at the required level, which in this paper is realized with the Fuzzy PI controller based on the field orientation control. For the Sinusoidal Pulse Width Modulation (SPWM) converter connected to the rotor side of DFIG to maintain the controllability of PQ at the state side of DFIM, the DC voltage of the DC link capacitor is also controlled at a certain level with the conventional Proportion-Integral (PI) controller of the real power. In addition, the power quality at the grid connected to the rotor side of DFIM through the back-to-back converter is maintained in a certain level with a PI controller of the reactive power. The controllers for the PQ at the stator side of DFIM, the DC link voltage of the back-to-back inverter and the reactive power at the grid connected to the rotor side of DFIM are designed and simulated in the PSIM program, of which the result verifies the performance of the proposed controllers.

키워드

참고문헌

  1. D. Panda, E. Bennedict, G. Venkataramanan, T. Lipo, "A Novel Control Strategy for the Rotor Side Control of a Double-Fed Induction Induction Machine", Proc. of IEEE lAS Annual Meeting, Vol. 3, pp. 1695-1702, 2001
  2. E. Tremblay, A. Chandra, P.J. Lagace, "Grid-side converter control of DFIG wind turbines to enhance power quality of distribution network", Proc. of IEEE PES Meeting, pp 18-22, June 2006
  3. B. H. Chowdhury, S. Chellapilla, "Double-fed Induction Generator Control for Variable Speed Wind Power Generation", Electric Power Systems Research, Vol. 76, pp. 786-800, June, 2006 https://doi.org/10.1016/j.epsr.2005.10.013
  4. M.T. Abolhassani, P. Enjeti, H.A. Toliyat, "Integrated doubly-fed electric alternator/active filter (IDEA), a viable power quality solution, for wind energy conversion systems", Proceedings of IEEE 39th lAS Annual Meeting, Vol. 3, pp. 2036-2043, 2004
  5. B. Hopfensperger, D.J. Atkinson, R.A. Lakin, "Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder", lEE Proc. Electr. Power. Appl., Vol. 147, No.4, pp. 241-250, July 2000 https://doi.org/10.1049/ip-epa:20000442
  6. W. Cheng, Longya Xu, "Torque and Reactive Power Control of a Doubly-Fed Induction Machine by Position Sensorless Scheme", Proceedings of IEEE lAS, pp. 496-502,1994
  7. M. Yamamoto, O. Motoyoshi, "Active and Reactive Power Control for Doubly Fed Wound Rotor Induction Generator", IEEE Trans. on PE, Vol.6, No.4, pp. 624-629, 1991 https://doi.org/10.1109/63.97761
  8. Z. Chen, "Compensation schemes for a SCR converter in variable speed wind power systems", IEEE Trans. on Power Delivery, Vol.19, No 2, pp. 813-821, April, 2004 https://doi.org/10.1109/TPWRD.2003.823189
  9. S. Muller, M. Deicke, R.W. De Doncker, "Adjustable speed generators for wind turbines based on doubly-fed induction machines and 4-quadrant IGBT converters linked to the rotor", IEEE IA Conf, pp 2249-2254, 2000
  10. B. Touftk, M. Machmoum, F. Poitiers, "Doubly fed induction generator with active filtering function for wind energy conversion system", Proceedings of EPE, p. 1-9, 2005
  11. Longya Xu, Yifan Tang, "A Novel Wind-Power Generating System Using Field Orientation Doubly-Excited Brushless Reluctance Machine", IEEE lAS Conf., pp. 408-413,1992
  12. S. Peresada, A. Tilli, A. Tonielli, "New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions", IEEE Trans. On Cntl. Syst. Tech., Vol. 11, No.6, pp. 875-888,2003 https://doi.org/10.1109/TCST.2003.819590
  13. Osama S. Ebrahim, Praveen K. Jain, Goel Nishith, "Indirect Stator Flux-Oriented Output Feedback Control of Doubly Fed Induction Machine", Journal of Power Electronics, Vol.8 No.1, pp. 10-22, Jan. 2008
  14. S. Drid, M. Nait-Said, M. Tadjine, "Double Flux Oriented Control for the Doubly Fed Induction Motor", Talyor & Francis, Electric Power Components and System, 33: pp.1081-1095, 2005 https://doi.org/10.1080/15325000590933483
  15. B. Heber, L. Xu, Y. Tang, "Fuzzy Logic Enhanced Speed Control of an Indirect Field Oriented Induction Machine Drive", Proceedings of PESC 95, Atlanta, pp. 1288-1294
  16. B.R. Lin, "Analysis of Neural and Fuzzy-Power Electronic Control", lEE Proc-SCI. Meas. Technol., Vol. 144, No.1, pp. 25-33, January 1997 https://doi.org/10.1049/ip-smt:19970516
  17. E. Muljadi, C.P. Butterfield, "Pitch-Controlled Variable Speed Wind Turbine Generation", IEEE Trans. On lA, Vol. 37, No 1, pp. 240-246, 2001 https://doi.org/10.1109/28.903156
  18. Bimal K. Bose, "Modern Power Electronics and AC Drives", Prentice Hall PTR, Upper-Saddle River, NJ, 2002
  19. DW. Novotny, T.A. Lipo, "Vector Control and Dynamics of AC Drives", Oxford Science Publications, New York, 1996
  20. PSIM User Manual, http://www.powersimtech.com/manual/ psim-manual/.pdf, Powersim Inc., 2006