DOI QR코드

DOI QR Code

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man (School of Electrical Engineering, Inha University) ;
  • Lee, Bok-Hee (School of Electrical Engineering, Inha University) ;
  • Paek, Seung-Kwon (Department of Electronics and Intelligent Robotics Engineering, Inje University)
  • 발행 : 2009.03.01

초록

This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.

키워드

참고문헌

  1. L. M. Faulkenberry and W. Coffer, 'Electrical Power Distribution and Transmission', $1^{st}$ ed., Prentice-Hall, Inc., Englewood Cliffs, pp.332-343, 1996
  2. M. Oyama, I. Ohshima, M. Honda, M. Yamashita and S. Kojima, 'Life Performance of Zinc-oxide Elements under DC voltage', IEEE Trans., Vol.PAS-101, No.6, pp.1363-1368, 1982
  3. A.J. Surtees, A. Stagoj, A. Pirih, and V. Crevenat, 'New Test Method to Determine the Short-Circuit Withstand Rating of an SPD', Proc. of 29th Intemational Conference on Lightning Protection, pp.7b-5-1-12, 2008
  4. Bok-Hee Lee and Sung-Man Kang, 'A Monitoring Device of Leakage Currents Flowing through ZnO Surge Arresters', Jpn J. Appl. Phys. Vol.42, Part 1, No.4A, pp .1568-1574, 2003 https://doi.org/10.1143/JJAP.42.1568
  5. Bok-Hee Lee and Sung-Man Kang, 'A new on-line leakage current monitoring systεm of ZnO surge arresters', J. Materials Sciεnce & Engineering B, Vol.119, No.1, pp13-18, 2005 https://doi.org/10.1016/j.mseb.2004.12.053
  6. A. Stagoj, V. Murko and A. Pirih, 'High energy lightning impulse discharge capability metal oxide varistors', Proc. of 28th Intemational Conference on Lightning Protection, pp.1097-1100, 2006
  7. Y. Miyakawa, T. Sakoda, M. Otsubo and M. Ikuta, 'Influence of Temperature Variation on Characteristics of ZnO Elements', Proc. of 2008 Int. Symp. on Electrical Insulating Materials, pp.119-122, 2008
  8. A. Haddad, et al., 'ZnO surge arrestεr elemεnts with mixed direct and 50 Hz voltages', IEE Proc., Pt. A, Vol.138, No.5, pp265-272, 1991
  9. R. B. Standler, Protection of Electronic Circuits from Overvoltages', John Wiley & Sons., Inc., pp.133-145, 1989
  10. W. G. Carlson, Dr. T. K. Gupta and A. Sweetana, 'A Procedure for Estimating the Lifetime of Gapless Metal Oxide Surge Arresters', lEEE Trans. PWRD-l, No.2, pp.67-74, 1986
  11. A. Haddad, J. Fuentεs-Rosado, D. M. German, R. T. Waters, 'Characterisation of ZnO surgε arrester elements with direct and power frequency voltages', lEE Proc. Vol. 137, No.5, pp.269-279, 1990

피인용 문헌

  1. Condition monitoring of electrical assets using digital IRT and AI technique 2018, https://doi.org/10.1016/j.jesit.2017.10.001
  2. Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents vol.27, pp.3, 2013, https://doi.org/10.5207/JIEIE.2013.27.3.079
  3. Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages vol.26, pp.4, 2012, https://doi.org/10.5207/JIEIE.2012.26.4.041