Performance Comparison of Various Types of $CO_2$ Compressors for Heat Pump Water Heater Application

  • 발행 : 2009.12.31

초록

Numerical simulations for scroll, two-stage twin rotary, and two-cylinder reciprocating compressors have been carried out to understand the effectiveness of each type compressor for heat pump water heater application using $CO_2$ as refrigerant. For suction pressure of 3.5 MPa and discharge pressure of 9 MPa, clearance volume ratio of the reciprocating compressor needs to be about 5% or less to have the volumetric efficiency comparable to that of the scroll compressor with tip clearance of $5\;{\mu}m$. Volumetric efficiency of the scroll compressor is quite sensitive to tip clearance. Adiabatic efficiency of the twin rotary compressor was calculated to be the lowest among the three types, and the most severe drawback of the $CO_2$ scroll compressor was a significant increase in the mechanical loss at the thrust surface supporting the orbiting scroll member. While the scroll compressor showed very smooth torque load variation, peak-to-peak torque variations of the twin rotary and two-cylinder reciprocating compressors were about 50% and 250%, respectively.

키워드

참고문헌

  1. Hwang, Y., 1997, Comprehensive investigation of carbon dioxide refrigeration cycle, Ph.D. Dissertation, University of Maryland, USA
  2. Neksa, P., Rekstad, H., Zakeri, G. R. and Schiefloe, P. A., 1998, $CO_{2}$ heat pump water heater: Characteristics, system design and experimental results, Int. Journal of Refrigeration, 21, p.172-179
  3. Neksa, P., 2002, $CO_{2}$ heat pump systems, Int. Journal of Refrigeration, 25(4), p.421-427 https://doi.org/10.1016/S0140-7007(01)00033-0
  4. Yanagisawa, T., Fukuta, M., Sakai, T., Kato, H., 2000, Basic operating characteristics of reciprocating compressor for $CO_{2}$ cycle, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.331-338
  5. Neksa, P., Dorin, F., Rekstad, H., Bredesen, A., 2000, Development of two-stage semi-hermetic $CO_{2}$ compressors, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.355-362
  6. Ohkawa, T., Kumakura, E., Higashi, H., Sakitani, K., Higuchi, M., Taniwa, H., Ozawa, H., 2002, Development of hermetic swing compressors for $CO_{2}$ refrigerant, Proc. Int. Compo Eng. Conference at Purdue, paper No. C25-1
  7. Tadano, M., Ebara, T., Oda, A., Susai, T., Takizawa, K., lzaki, H., and Komatsubara, T., 2000, Development of the $CO_{2}$ hermetic compressor, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.323-330
  8. Fukuta, M., Radermacher, R., Lindsay, D., Yanagisawa, T., 2000, Performance of vane compressor for $CO_{2}$ cycle, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.339-346
  9. Hasegawa, H., Ikoma, M., Nishiwaki, F., Shintaku, H. and Yakumaru, Y., 2000, Experimental and theoretical study of hermetic $CO_{2}$ scroll compressor, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.347-354
  10. Saikawa, M. and Hashimoto, K., 2000, Development of prototype of $CO_{2}$ heat pump water heater for residential use, 4th IIR-Gustav Lorenzen Conference on Natural Working Fluids at Purdue, p.51-57
  11. Kim, H. J., 2003, Computer simulation programs for reciprocating, rolling piston rotary, and scroll compressors. Scroll Laboratory Report, University of Incheon
  12. Huang, Y., 1994, Leakage calculation through clearances, Proc. Int. Compo Eng. Conference. at Purdue, p.35-40
  13. S$\ddot{u}$B, J., 2000, Impact of refrigerant fluid properties on the compressor selection, Proc. Int. Compo Eng. Conference at Purdue, p.213-220