Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement

부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가

  • 박대원 (한국해양대학교 전기전자공학부) ;
  • 박찬용 (한국해양대학교 전기전자공학부) ;
  • 최재성 (한국해양대학교 전기전자공학부) ;
  • 길경석 (한국해양대학교 전기전자공학부) ;
  • 이강원 (한국철도기술연구원 바이모달수송시스템연구단)
  • Published : 2009.04.30

Abstract

This paper dealt with the insulation evaluation by a measurement of partial discharge(PD) on traction motors used in a hybrid vehicle. The PD method has been accepted as an effective and a non-destructive. technique to evaluate insulation performance of low-voltage electric and electronic devices. In this paper, the PD measurement system which was manufactured with a coupling network, a low noise amplifier, and an associated electronics is described. The PD measurement system has the frequency bandwidth of $1[MHz]{\sim}30[MHz]$ at -3 [dB] and the stable sensitivity of 19 [mV/pC] for the traction motor. From the experimental results, discharge inception voltage (DIV) and apparent charge (q) were $1,100[V_{rms}]$ and 105 [pC] for the used motor, and $1,400[V_{rms}]$ and 84 [pC] for the new one. By comparing the DIV and q, we could evaluate the insulation condition for the traction motors.

본 논문에서는 부분방전 측정에 의한 하이브리드 차량용 견인전동기의 절연평가에 대하여 기술하였다. 부분방전법은 효과적인 비파괴시험으로 저압용 전기전자기기의 절연성능평가에 사용되어 왔다. 부분방전 측정시스템은 결합회로망, 저잡음 증폭회로 및 주변 전자회로로 구성되며, 주변 잡음의 영향을 최소화하기 위하여 차폐함내에 설치하였다. 교정실험으로부터 부분방전 측정시스템의 주파수 대역은 $1[MHz]{\sim}30[MHz]$ (-3[dB]), 감도는 19[mV/pC]로 평가되었다. 기사용 전동기와 신품 전동기에서 방전개시전압(DIV)과 겉보기 전하량(q)을 측정한 결과, 기사용 전동기의 방전개시전압은 $1,100[V_{rms}]$, 겉보기 전하량은 105[pC], 신품 전동기에서의 방전개시전압은 $1,400[V_{rms}]$, 겉보기 전하량은 84[pC]이었다. 방전개시전압과 전하량을 비교함으로써 견인전동기의 절연상태를 평가할 수 있었다.

Keywords

References

  1. H. Brandes and J. A. Allison (2000), "Insulating Systems for Inverter-Driven Motors; Status and Developments", Power Engineering Journal, Vol.14, No.4, pp.164-168 https://doi.org/10.1049/pe:20000403
  2. L. Gubbala, A. Von Jouanne, P.N Enjeti, C. Singh, H. A. Toliyat (1995), "Voltage Distribution in the Windings of an AC Motor Subjected to High dv/dt PWM Voltages", Power Electronics Specialists Conference, 1995. PESC'95, 26th Annual IEEE, Vol.1, pp.579-585
  3. Christopher J. Melhorn, Le Tang(1997), "Transients Effects of PWM Drives on Induction Motors", IEEE Trans. on Industry Applications, Vol.33, No.4, pp.1065-1072 https://doi.org/10.1109/28.605750
  4. G. Suresh, H.A. Toliyat, D.A. Rendusara, P.N. Enjeti (1999), "Predicting the transient Effects of PWM Voltage Waveform on the Stator Winding of Random Wound Induction motors", IEEE Trans. on Power Electronics, Vol.14, No.1, pp.23-30 https://doi.org/10.1109/63.737589
  5. A. H. Bonnett(1996), "Analysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors", IEEE Trans. on LAS, Vol.32, pp.386-392 https://doi.org/10.1109/28.491488
  6. Martin Kaufhold, Herbert Auinger, Matthias Berth, Joachim Speck, and Martin Eberhardt (2000), "Electrical Stress and Failure Mechanism of the Winding Insulation in PWM-Inverter-Fed Low-Voltage induction Motors", IEEE Transactions on Insulation Electrical Vol.47, No.2, pp.396-402 https://doi.org/10.1109/41.836355
  7. 길경석, 류길수, 박대원, 조영진, 천상규, 최수연(2007), "인버터구동 유도전동기에서 과도전압의 측정과 분석", 한국철도학회논문집, 제10권 제6호, pp.650-654
  8. A. Cavallini, M. Conti, A. Contin, and G. C. Montanari (2003), "Advanced PD Inference in On-Field Measurements. Part 2: Identification of Defects in Solid Insulation Systems", IEEE Trans. on Dielectrics and Electrical Insulation, Vol.10, No.3, p.527
  9. R. C ndela, G. Mrelli and R. Schifani (2000), "PD Recognition by Means of Statical and Fractal Parameters and a Neural Network", IEEE Transactions on Dielectrics and Electrical Insulation, Vol.7, No.1, pp.87-94 https://doi.org/10.1109/94.839345
  10. G. C. Stone, T. E. Goodeve, H. G. Sedding and W. McDermid(1995), "Unusual PD Pulse Distributions in Operating Machines", IEEE Transactions on Dielectrics and Electrical Insulation, Vol.2, No.4, pp.567-577 https://doi.org/10.1109/94.407022
  11. Gyung-Suk Kil, Jae-Yong Song, Jae-Man Song, Don-Ha Hwang, Dong-Sik Kang, Yong-Ju Kim (2006), "Study on a Partial Discharge Test for Low- Voltage Electronic Components", Journal of Korean Physical Society, Vol.49, No.6, pp.2311-2315
  12. 길경성, 송재요으 문승보, 차명수, 황돈하, 강동식 (2006), "저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구", 한국전기전자재료학회논문지, 제19권 제6호, pp.586-590 https://doi.org/10.4313/JKEM.2006.19.6.586
  13. F. H. Kreuger(1989), "Partial Discharge Detection in High-Voltage Equipment", p.129
  14. IEC 60270 Publication(2001), "High-Voltage Test Techniques-Partial Discharge Measurement"