Abstract
In this paper, the multi-camera calibration algorithm for optical motion capture system is proposed. This algorithm performs 1st camera calibration using DLT(Direct linear transformation} method and 3-axis calibration frame with 7 optical markers. And 2nd calibration is performed by waving with a wand of known length(so called wand dance} throughout desired calibration volume. In the 1st camera calibration, it is obtained not only camera parameter but also radial lens distortion parameters. These parameters are used initial solution for optimization in the 2nd camera calibration. In the 2nd camera calibration, the optimization is performed. The objective function is to minimize the difference of distance between real markers and reconstructed markers. For verification of the proposed algorithm, re-projection errors are calculated and the distance among markers in the 3-axis frame and in the wand calculated. And then it compares the proposed algorithm with commercial motion capture system. In the 3D reconstruction error of 3-axis frame, average error presents 1.7042mm(commercial system) and 0.8765mm(proposed algorithm). Average error reduces to 51.4 percent in commercial system. In the distance between markers in the wand, the average error shows 1.8897mm in the commercial system and 2.0183mm in the proposed algorithm.
본 논문에서는 광학식 모션캡처 장비를 위한 다중 카메라 보정 방법을 제안한다. 이 방법은 DLT(Direct linear transformation) 알고리즘을 이용하여 7개의 마커가 있는 3축 보정틀의 영상을 획득하여 1차 카메라 보정을 한다. 그리고 2개의 마커가 있는 보정봉을 측정하고자 하는 영역에서 움직여서 2차 카메라 보정을 실시한다. 1차 카메라 보정에서는 카메라 보정뿐만 아니라 렌즈 왜곡 계수를 계산하여 2차 카메라 보정에서의 최적화를 위한 초기해로 사용한다. 2차 카메라 보정에서는 보정봉에 있는 마커사이의 거리가 일정하기 때문에 계산된 마커 거리와 실제 마커 거리의 차가 최소화 되도록 최적화를 수행한다. 제안한 방법에 의한 다중 카메라 보정 방법을 검증하기 위하여 재투영에러를 계산하였고 3축 보정틀에 있는 마커사이의 거리와 보정봉에 있는 마커사이의 거리를 계산하여 다른 상용장비의 값과 비교하였다. 3축 보정틀에 있는 마커를 복원하여 에러를 비교한 결과 평균오차가 상용장비의 1.7042mm에 비해 0.8765mm로 51.4% 수준으로 나타났고, 보정봉에 있는 마커를 복원하여 에러를 비교한 결과 상용장비의 평균에러 1.8897mm에 비해 2.0183mm로 0.1286mm 크게 나타났다.