References
- F. M. Khan, The Physics of Radiation Therapy, 2nd ed. (Williams & Wilkins, Baltimore, USA, 1994), pp. 8-10
- W. Plastinoa, I. Chereji, S. Cuna, L. Kaihola, P. D. Felice, N. Lupsa, G. Balas, V. Mirel, P. Berdea, and C. Baciu, 'Tritium inwater electrolytic enrichment and liquid scintillation counting,' Radiation Measurements 42, 68-73 (2007) https://doi.org/10.1016/j.radmeas.2006.07.010
- J. Magill and J. Galy, Radioactivity Radionuclides Radiation (Springer, Berlin, Germany, 2005), pp. 137
- J. Chen, 'Radiation quality of tritium,' Radiation Protection Dosimetry 122, 546-548 (2006) https://doi.org/10.1093/rpd/ncl411
- B. Liu, D. Alvarez-Ossa, N. P. Kherani, S. Zukotynski, and K. P. Chen, 'Gamma-free smoke and particle detector using tritiated foils,' IEEE Sensors Journal 7, 917-918 (2007) https://doi.org/10.1109/JSEN.2007.895971
- A. S. Beddar, 'Plastic scintillation dosimetry and its application to radiotherapy,' Radiation Measurements 41, S124-S133 (2007) https://doi.org/10.1016/j.radmeas.2007.01.002
- B. Lee, K. W. Jang, D. H. Cho, W. J. Yoo, G. R. Tack, S. C. Chung, S. Kim, and H. Cho, 'Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry,' Nucl. Instrum. Phys. Res. A 579, 344-348 (2007) https://doi.org/10.1016/j.nima.2007.04.074
- A. S. Beddar, T. J. Kinsella, A. Ikhlef, and C. H. Sibata, 'A Miniature 'scintillator-fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery,' IEEE Trans. Nucl. Sci. 48, 924-928 (2001) https://doi.org/10.1109/23.940133
- K. W. Jang, D. H. Cho, S. H. Shin, H. S. Kim, J. H. Yi, B. Lee, S. Kim, and H. Cho, 'Fabrication and characterization of two-dimensional fiber-optic radiation sensor for high energy photon beam therapy dosimetry,' Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 18, 241-245 (2007). https://doi.org/10.3807/HKH.2007.18.4.241
- K. W. Jang, B. Lee, D. H. Cho, H. S. Kim, J. H. Yi, J. W. Lee, S. Kim, and H. Cho, 'Removal of cerenkov light in fiber-optic radiation sensor using optical filters,' Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 17, 312-316 (2006) https://doi.org/10.3807/KJOP.2006.17.4.312
- G. F. Knoll, Radiation Detection and Measurement, 3rd ed. (John Wiley & Sons, USA, 1999), pp. 233-234
- H. Cember, Introduction to Health Physics, 3rd ed. (McGraw-Hill, USA, 1996), pp. 423-424
Cited by
- Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution vol.24, pp.3, 2015, https://doi.org/10.5369/JSST.2015.24.3.202
- Development of a fiber-optic gamma endoscope to measure both optical and gamma images in a confined space vol.25, pp.17, 2017, https://doi.org/10.1364/OE.25.020087
- Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes vol.2017, 2017, https://doi.org/10.1155/2017/1452765