공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment

  • 김성수 (한양대학교 건축공학과) ;
  • 손장열 (한양대학교 건축공학과)
  • 발행 : 2009.10.10

초록

It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

키워드

참고문헌

  1. Kim, S. S., Son, J. Y., Kim, T. J., Kim, H. J. and Pack, J. S., 2008, Performance Evaluation of Multidrop Chamber Ventilation System in Apartment, Proceeding of the KAIEBS 2008 Autumn Annual Conference, pp. 149-153
  2. Park, Y. W., Park, M. S. and Lee, D. W., 1995, A Numerical Study for Balancing CAV Duct System, Proceeding of Architectural Institute of Korea, Vol. 15, No. 2, pp. 333-336
  3. Lee, D. W., Park, Y. W. and Park, M. S., 1998, Balancing air flow at terminal in CAV duct system with DPM method, SAREK, Vol. 10, No. 1, pp. 66-78
  4. Go, S. H., Lee, H. J. and Park, J. C., 2004, An Experimental study of Ventilation Effectiveness according to Duct Layouts in Apartment Units, SAREK 2008 Winter Annual Conference, pp. 156-159
  5. Song, J. W., Kang, I. K., Kim, S. S., Won, C. H. and Kim, G. O., 2004, Measurements of Flow Resistance in AD to Develope Heat Recovery Ventilator for Highrise Apartment Complex, SAREK 2008 Summer Annual Conference, pp. 362-367
  6. Yang, S. B., Yoon, D. W., Hong, S. M., Kim, J. H., Lee, J. Y. and Lee, S. C., 2008, An Evaluation on the Performance of Air Distributor with Split Guide Vane and its Proper Installation in Residential Ventilation System, Proceeding of the KIAEBS 2008 Autumn Annual Conference
  7. Yee, J. J., Choi, S. Y., Kim, S. K., Kim, K. H., Lee, Y. W. and Kim, H. Y., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, SAREK, Vol. 19, pp. 770-775
  8. Yoon, D. W. and Yang, S. B., 2009 An, Evaluation on the Performance of Air Distributor with Split Guide Vaneand EVA Flexible Duct in Residential Ventilation System, Journal of Architectural Institute of Korea, Vol. 25, No. 7, pp. 350-312
  9. Choi, J. H., Ju, S. Y. and Yee, J. J., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, Proceeding of SAREK, pp. 1037-1043