초록

The flow field measurements were conducted on the planes between impeller blades, and the gap between the impeller and turbine blades under speed ratio of 0.4. The study showed that high velocity regions move from locations near the suction surface of the impeller to the pressure blade, shroud corner as flow progresses from the mid-chord of impeller passage to exit and out into the gap region. Planes 3 through 5 also showed flow reversal occurring in the area near the shell surface and progress far into the impeller passage from the impeller passage exit, near shell surface. This affected the converter efficiency negatively. This study would aid in the construction of higher accuracy CFD models of this complex turbomachinery device.

키워드

참고문헌

  1. Keunchul K. Lee, Seoung-Chool Yoo and Harold J.Schock, 2000, “Quantification of Primary Flows ofa Torque Converter Using Laser Doppler Velocimetry”,SAE Paper No. 2000-05-0106.
  2. S. C. Yoo and S. K. Jang, 2009, “A Study on theFlow Characteristics in a Torque Converter”, Journalof the Korean Society for Power System Engineering,Vol. 12(5), pp. 20-26.
  3. S. C. Yoo and S. K. Jang, 2009, “Flow Field Measurementsin a Torque Converter (II)”, Journal ofthe Korean Society for Power System Engineering,Vol. 13(6), pp. 82-87.
  4. B. Lakshminarayna and T. W. Backstorm, 1996,“Perspective: Fluid Dynamics and Performance ofAutomotive Torque Converters: An Assessment”,Journal of Fluids Engineering, Vol. 118, pp. 665-676. https://doi.org/10.1115/1.2835494
  5. J. K. Gruver, R. D. Flake and K. Brun, 1996, “LaserVelocimeter Measurements on the pump of an AutomotiveTorque Converter: Part I- Average Measurements”,Trans. of ASME, Vol. 118, pp. 562-569. https://doi.org/10.1115/1.2822668
  6. W. Fister and F. W. Adrian, 1983, “ExperimentalResearches of Flow in Hydrodynamic Torque Converters", Proceeding of the 7th Conference of FluidMachinery in Budapest, Hungary, Vol. 1, pp. 210-224.
  7. R. R. By and J. E. Maloney, 1988, “TechnologyNeeds for the Automotive Torque Converter-Part 1:Internal Flow, Blade Design, and Performance”,SAE Paper No. 880482.
  8. H. M. Bahr, R. D. Flack, R. R. By and J. J. Zhang,1990, “Laser Velocimetry Measurements in the Statorof a Torque Converter”, SAE Paper No.901769.
  9. R. R. By and B. Lakshminarayna, 1995, “Measurementand Analysis of Static Pressure Field in aTorque Converter Pump”, Journal of Fluids Engineering,Vol. 117, pp. 109-115. https://doi.org/10.1115/1.2816798
  10. S. Shin, H. H. Ahn and T. K. Lee, 1998, “PerformanceAnalysis of a Torque Converter with ThreeDimensional Flow Simulation”, KSAE Paper No.98370120.