Isolation of Environmental Mycobacteria from Diverse Water Samples Using Cetylpyridinium Chloride

  • Choi, Yeon-Im (Department of Biomedical Laboratory Science, College of Health Sciences, Yonsei University) ;
  • Jin, Hyun-Woo (Department of Biomedical Laboratory Science, College of Health Sciences, Yonsei University) ;
  • Lee, Gyu-Sang (Department of Biomedical Laboratory Science, College of Health Sciences, Yonsei University) ;
  • Kim, Jong-Bae (Department of Biomedical Laboratory Science, College of Health Sciences, Yonsei University) ;
  • Song, In-Kenn (Division of Biotechnology, The Catholic University) ;
  • Kim, Young-Joon (Division of Biotechnology, The Catholic University) ;
  • Lee, Hye-Young (Department of Biomedical Laboratory Science, College of Health Sciences, Yonsei University)
  • 투고 : 2010.06.18
  • 심사 : 2010.09.27
  • 발행 : 2010.09.30

초록

Despite of the increasing importance of environmental mycobacteria, detection and identification of mycobacteria from environmental sources including water have been fraught with technical difficulties. Although, several protocols to optiruize isolation of mycobacteria from water sources have been reported, standard method has not yet been established. In this study, usefulness of cetylpyridinium chloride (CPC), a cationic quaternary ammonium compound, for the isolation of environmental mycobacteria from diverse water samples was evaluated. For this, water samples from diverse water sources such as effluent water, lake water, and underground water were collected, treated with diverse concentrations of CPC, and plated on the solid agar plates. Subsequently individual colonies grown on the plates were sequence analyzed for identification of each colony. In brief, the results from this study showed that the growth of mycobacteria was enhanced by use of CPC as a pre-treatment reagent to water samples by inhibiting growth of other non-mycobacteria in water. In fact, the effect of CPC to decontaminate non-mycobacteria for isolation of mycobacteria was better than 1~4% of NaOH, which is a routinely used decontaminating reagent widely employed for culturing mycobactera from sputum specimens. Therefore, the results from this study seems to support that the CPC pre-treatment may be useful for isolation of mycobacteria from diverse sources including clinical specimens which are often contaminated with other bacteria.

키워드

참고문헌

  1. American Public Health Association. Standard methods for the examination of water and wastewater. 1995. p. 120-1 50 19th ed. American Public Health Association, Washington, D.C., USA.
  2. Chang CT, Wang LY, Liao CY, Huang SP. Identification of nontuberculous mycobacteria existing in tap water by PCRrestriction fragment length polymorphism. Appl Environ Microbiol. 2002.68: 3159-3161. https://doi.org/10.1128/AEM.68.6.3159-3161.2002
  3. Covert TC, Rodgers MR, Reyes AL, Jr Stelma GN. Occurrence of nontuberculous mycobacteria in environmental samples. Appl Environ Microbiol. 1999.65: 2492-2496.
  4. Dailloux MC, Weber LM, Hartemann P. Water and nontuberculous mycobacteria. Water Res. 1999. 33: 2219-2228. https://doi.org/10.1016/S0043-1354(98)00466-7
  5. Du Moulin GC, Stottmeier KD. Use of cetylpyridinium chloride in the decontamination of water for culture of mycobacteria. Appl Environ Microbiol. 1978. 36: 771-773.
  6. Du Moulin GC, Stottmeier KD. Waterborne mycobacteria: an increasing threat to health. ASM News. 1986. 52: 525-529.
  7. Du Moulin GC, Stottmeier KD, Pelletier PA, Tsang AY, Hedley- Whyte J. Concentration of Mycobacterium avium by hospital hot water systems. JAMA. 1988. 260: 1599-1601. https://doi.org/10.1001/jama.260.11.1599
  8. Embil J, Warren P, Yakrus M, Stark R, Come S, Forrest D, Hershfield E. Pulmonary illness associated with exposure to Mycobacterium avium complex in hot tub water. Hypersensitivity pneumonitis or infection? Chest. 1997. 111: 813-816. https://doi.org/10.1378/chest.111.3.813
  9. Falkinham JO 3rd. Epidemiology of infection by nontuberculous mycobacteria. Clin Microbiol Rev. 1996. 9: 177-215.
  10. Falkinham JO 3rd, Norton CD, LeChevallier MW. Factors influencing numbers of Mycobacterium avium, Mycobacterium intracellulare, and other Mycobacteria in drinking water distribution systems. Appl Environ Microbiol. 2001. 67: 1225-1231. https://doi.org/10.1128/AEM.67.3.1225-1231.2001
  11. Falkinham JO 3rd, nontuberculous mycobacteria in the environment. Clin Chest Med. 2002. 23: 529-551. https://doi.org/10.1016/S0272-5231(02)00014-X
  12. Falkinham J. Environmental sources of Mycobacterium avium linked to routes of exposure. Pathogenic mycobacteria in water: a guide to public health consequences, monitoring management. 2004. IWA Publishing, London, United Kindom.
  13. Goslee S, Wolinsky E. Water as a source of potentially pathogenic mycobacteria. Am Rev Respir Dis. 1976. 113: 287-292.
  14. Kazda JF. The principles of the ecology of mycobacteria, The biology of mycobacteria, 1983. vol. 2. cademic Press, London, United Kingdom.
  15. Korea ministry of Environment. Bacterial contamination guidelines for drinking water in Korea 2002.
  16. Kubalek I, Komenda S. Seasonal variations in the occurrence of environmental mycobacteria in potable water. APMIS. 1995. 103: 327-330. https://doi.org/10.1111/j.1699-0463.1995.tb01115.x
  17. Kubalek I, Mysak J. The prevalence of environmental mycobacteria in drinking water supply systems in a demarcated region in Czech Republic, in the period 1984-1989. Eur J Epidemiol. 1996.12: 471-474. https://doi.org/10.1007/BF00143998
  18. Le Dantec C, Duguet JP, Montiel A, Dumoutier N, Dubrou S, Vincent V. Chlorine disinfection of atypical mycobacteria isolated from a water distribution system. Appl Environ Microbiol. 2002. 68: 1025-1032. https://doi.org/10.1128/AEM.68.3.1025-1032.2002
  19. Le Dantec C, Duguet JP, Montiel A, Dumoutier N, Dubrou S, Vincent V. Occurrence of mycobacteria in water treatment lines and in water distribution systems. Appl Environ Microbiol. 2002.68: 5318-5325. https://doi.org/10.1128/AEM.68.11.5318-5325.2002
  20. Leoni E, Legnani P, Mucci MT, Pirani R. Prevalence of mycobacteria in a swimming pool environment. J Appl Microbiol. 1999. 87: 683-688. https://doi.org/10.1046/j.1365-2672.1999.00909.x
  21. Lemarchand K, Berthiaume F, Maynard C, Harel J, Payment P, Bayardelle P, Masson L, Brousseau R Optimization of microbial DNA extraction and purification from raw wastewater samples for downstream pathogen detection by microarrays. J Microbiol Methods. 2005.63: 115-126. https://doi.org/10.1016/j.mimet.2005.02.021
  22. Livanajnen E, Northrup J, Arbeit RD, Ristola M, Katila ML, Von Reyn CF. Isolation of mycobacteria from indoor swimming pools in Finland. APMIS. 1999. 107: 193-200. https://doi.org/10.1111/j.1699-0463.1999.tb01544.x
  23. Schulze-Robbecke R, Weber A, Fischeder R. Comparison of decontamination methods for the isolation of mycobacteria from drinking water samples. J Microbiol Methods. 1991. 14: 177-183. https://doi.org/10.1016/0167-7012(91)90021-H
  24. Songer JG. Methods for selective isolation of mycobacteria from the environment. Can J Microbiol. 1981. 27: 1-7. https://doi.org/10.1139/m81-001
  25. Vaerewijck MJ, Huys G, Palomino JC, Swings J, Portaels F. Mycobacteria in drinking water distribution systems: ecology and significiance for human health. FEMS Microbiol Rev. 2005. 29: 911-934. https://doi.org/10.1016/j.femsre.2005.02.001