DOI QR코드

DOI QR Code

An Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame

  • Phan, Van-Tung (School of Electrical Engineering, University of Ulsan) ;
  • Lee, Hong-Hee (School of Electrical Engineering, University of Ulsan) ;
  • Chu, Tae-Won (School of Electrical Engineering, University of Ulsan)
  • Received : 2010.03.29
  • Published : 2010.11.20

Abstract

This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposing the positive and negative sequence components of the measured rotor current. In addition, the behavior of the proposed controller is examined in terms of control performance and stability with respect to rotor speed variations, i.e., slip frequency variations. Simulations and experimental results are shown to validate the robustness and effectiveness of the proposed control method.

Keywords

References

  1. Daniel G. Forchetti, Guillermo O. Garcia and Maria Ines Valla, "Adaptive observer for sensorless control of stand-alone doubly fed induction generator," IEEE Transactions on Industrial Electronics, Vol. 56, No. 10, pp. 4174-4180, Oct. 2009. https://doi.org/10.1109/TIE.2009.2014907
  2. R. Pena, J. C. Clare and G. M. Asher, "A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine," IEE Proc. Electric Power Applications., Vol. 143, No. 5, pp. 380-387, Sep. 1996. https://doi.org/10.1049/ip-epa:19960454
  3. S. Muller, M. Deicke, R.W, and De Doncker, "Doubly fed induction generator system for wind turbines," IEEE Industry Application Magazine, Vol. 8, No. 3, pp. 26-33, May 2002. https://doi.org/10.1109/2943.999610
  4. Arantxa Tapia, Gerardo Tapia, J. Xabier Ostolaza, and Jose Ramon Saenz, "Modeling and control of a wind turbine driven doubly fed induction generator," IEEE Transactions on Energy Conversion, Vol. 18, No. 2, pp. 194-204, Jun. 2003. https://doi.org/10.1109/TEC.2003.811727
  5. Lie Xu, Yi Wang, "Dynamic modeling and control of DFIG-based wind turbine under unbalanced network conditions," IEEE Transactions on Power Systems, Vol. 22, No. 1, pp. 314-323, Feb. 2007. https://doi.org/10.1109/TPWRS.2006.889113
  6. Yi Zhou, Paul Bauer, Jan A. Ferreira, and Jan Pierik, "Operation of grid-connected DFIG under unbalanced grid voltage condition," IEEE Transactions on Energy Conversion, Vol. 24, No. 1 pp. 240-246, Mar. 2009. https://doi.org/10.1109/TEC.2008.2011833
  7. David Santos-Martin, Jose Louis Rodriguez-Amenedo, and Santiago Arnalte, "Direct power control applied to doubly fed induction generator under unbalanced grid voltage conditions," IEEE Transactions on Power Electronics, Vol. 23, No. 5, pp. 2328-2336, Sep. 2008. https://doi.org/10.1109/TPEL.2008.2001907
  8. Gonzalo Abad, Miguel Angel Rodriguez, Grzegorz Iwanski, and Javier Poza, "Direct power control of doubly fed induction generator based wind turbines under unbalanced grid voltage," IEEE Transactions Power Electronics, Vol. 25, No. 2, pp. 442-452, Feb. 2010. https://doi.org/10.1109/TPEL.2009.2027438
  9. R. Pena, et al, "Control system for unbalanced operation of standalone doubly fed induction generator", IEEE Transactions on Energy Conversion, Vol. 22, No. 2, pp. 544-545, Jun. 2007. https://doi.org/10.1109/TEC.2007.895393
  10. R. Pena, et al, "Control strategy for a doubly fed induction generator feeding an unbalanced grid or stand-alone load," Electric Power Systems Research, Jul. 2008
  11. R. Teodorescu, et al, "Proportional-resonant controllers and filters for grid-connected voltage source converters," Electric Power Application, IEE Proceedings, Vol. 153, No. 5, pp. 750-762, Sep. 2006. https://doi.org/10.1049/ip-epa:20060008
  12. Marco Liserre, Remus Teodorescu, and Frede Blaabjerg, "Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame," IEEE Transactions on Power Elecronics, Vol. 21, No. 3, pp. 836-841, May 2006. https://doi.org/10.1109/TPEL.2006.875566
  13. D. N. Zmood and D. G. Holmes, "Stationary frame current regulation of PWM inverters with zero steady state error," IEEE Transactions on Power Electronics, Vol. 18, No. 3, pp 814-822, May 2003 https://doi.org/10.1109/TPEL.2003.810852
  14. Van-Tung Phan, Hong-Hee Lee, and Tae-Won Chun, "An improved control strategy using PI-resonant controller for unbalanced stand-alone doubly fed induction generator," Journal of Power Electronics, Vol. 10, No. 2, pp. 194-202, Mar. 2010. https://doi.org/10.6113/JPE.2010.10.2.194
  15. Marian P. Kazmierkowski, R. Krishnan, F. Blaabjerg, Control in Power Electronics: selected problems, Academic Press, 2002.

Cited by

  1. Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance vol.20, pp.1, 2015, https://doi.org/10.6113/TKPE.2015.20.1.91
  2. Vector control optimization of DFIGs under unbalanced conditions vol.28, pp.8, 2018, https://doi.org/10.1002/etep.2583