The 125kW external reforming (ER) type molten carbonate fuel cell (MCFC) system for developing a commercial prototype has been operated at Boryeong thermal power plant site since the end of 2009. The system consists of 125kW stack with $10,000 cm^2$ effective area, mechanical balance of plant (MBOP) with anode recycle system, and electrical balance of plant (EBOP). The 125kW MCFC stack installed in December, 2009 has been operated from January, 2010 after 20 days pre-treatment. The stack open circuit voltage (OCV) was 214V at initial load operation, which approaches the thermodynamically theoretical voltage. The stack voltage remained stable range from 160V to 180V at the maximum generating power of 120 kW DC. The stack has been operated for 3,270 hours and operated at rated power for 1,200 hours.

Keywords

References

  1. 임희천, 강승원, 김도형, 김범주, 이정현 "250kW급 열병합 용용탄산염 연료전지 Proto Type개발 및 평가기술개발(2단계 최종보고서)", 한전 전력연구원, 대전, 2010.
  2. 임희천, 안교상, 김도형, 강승원, 김범주 "250kW 발전용 용용탄산염 연료전지 기술 개발(시스템 및 BOP 설계)", 대한전기학회 하계학술대회 논문집, 2007, pp. 195-196.
  3. Hee-Chun Lim, Do-Hyung Kim, Seung-Won Kang, Beum-Ju Kim, Jung-Hyun Lee, and Jong-Hwan Jun: "A Test Results of a 75 kW MCFC Short Stack with 1 m2 separator for 250 kW MCFC system Development", Proceedings of 10th AHEC, Korea, 2009, p. 77.
  4. 강승원, 김범주, 김도형, 이정현, 김의환, 임희천: "75kW 용용탄산염 연료전지(MCFC)스택 운전 결과", 한국수소 및 신에너지학회논문집, Vol. 19, No. 5, 2009, pp. 202-207.
  5. 김도형, 김범주, 이정현, 강승원, 임희천, "전기 부하에 따른 용용탄산염 연료전지 스택 온도 분포에 관한 수치 해석 연구", 한국수소 및신에너지학회 논문집, Vol. 21, No. 4, 2010, pp. 258-263.