DOI QR코드

DOI QR Code

A Fault-Tolerant Control Strategy for Cascaded H-Bridge Multilevel Rectifiers

  • Published : 2010.01.20

Abstract

Reliability is an important issue in cascaded H-bridge converters (CHB converters) because they use a high number of power semiconductors. A faulty power cell in a CHB converter can potentially lead to expensive downtime and great losses on the consumer side. With a fault-tolerant control strategy, operation can continue with the undamaged cells; thus increasing the reliability of the system. In this paper, the operating principles and the control method for a CHB multilevel rectifier are introduced. The influence of various faults on the CHB converter is investigated. The method of fault diagnosis and the bypassing of failed cells are explained. A fault-tolerant protection strategy is proposed to achieve redundancy in the CHB rectifier. The redundant H-bridge concept helps to deal with device failures and to increase system reliability. Simulation results verify the performance of the proposed strategy.

Keywords

References

  1. J. S. Lai and F. Z. Peng, "Mutilevel converters – A new breed of power converters," IEEE Trans. Ind. Appl., Vol. 32, No. 3, pp. 509–517, May/Jun. 1996. https://doi.org/10.1109/28.502161
  2. M. Massoud, S. J. Finney, and B. W. Williams, "High-power, highvoltage IGBT applications: series connection of IGBTs or multilevel converters?," INT. J. ELECTRONICS, Vol. 90, No. 11–12, pp. 763–778, 2003. https://doi.org/10.1080/00207210310001666429
  3. Han, B. Bae, S. Baek, and G. Jang, "New Configuration of UPQC for Medium-Voltage Application," IEEE Trans. Power Delivery, Vol. 21, No. 3, pp. 1438-1444, Jul. 2006. https://doi.org/10.1109/TPWRD.2005.860235
  4. M. F. Escalante, "Cascaded H-Bridge Multilevel Active Compensator," in IEEE Int. Power Electronics Congress, Puebla, Mexico, pp. 1 – 6, Oct. 2006.
  5. J. Rodriguez, J. S. Lai, and F. Z. Peng, "Multilevel inverters: a survey of topologies, control, and applications," IEEE Trans. Industrial Electronics, Vol. 49, Issue 4, pp. 724 – 738, Aug. 2002. https://doi.org/10.1109/TIE.2002.801052
  6. Cecati, A. Dell, M. Liserre, and V. G. Monopoli, "Design of H-Bridge Multilevel Active Rectifier for Traction Systems," IEEE Trans. Industry Applications, Vol. 39, No. 5, pp. 1541 – 1550, Set.-Oct. 2003. https://doi.org/10.1109/TIA.2003.816515
  7. G. Brando, A. Dannier, and A. Del Pizzo, "An Optimized Control Technique of Cascaded H-bridge Multilevel Active Front-ends," in IEEE Int. Power Electronics and Motion Control Conf., EPE-PEMC 2006, Portoroz , Slovenia , pp. 793 – 799, Aug. 2006.
  8. G. Sinha, C. Hochgraf, R. H. Lasseter, D. M. Divan, and T. A. Lipo, "Fault protection in a multilevel inverter implementation of a static condenser," IEEE IAS Annual Meeting, Conf., pp. 2557-2564, 1995.
  9. C. Turpin, P. Baudesson, F. Richardeau, F. Forest, and T. A. Meynard, "Fault management of multicell converters," IEEE Trans. Ind. Electron., Vol. 49, pp. 988-997, Oct. 2002. https://doi.org/10.1109/TIE.2002.803196
  10. J. Rodriguez, P. W. Hammond, J. Pontt, R. Musalem, P. Lezana, and M. J. Escobar, "Operation of a medium-voltage drive under faulty conditions," IEEE Trans. Industry Electronics, Vol. 52, pp. 1080-1085, 2005. https://doi.org/10.1109/TIE.2005.851645
  11. S.Wei, B.Wu, F. Li, and X. Sun, "Control method for cascaded H-bridge multilevel inverter with faulty power cells," in Proc. IEEE Applied Power Electronics Conf., Miami, FL, Vol. 1, pp. 261-267, Feb. 2003.
  12. H. Iman-Eini, J-L. Schanen, Sh. Farhangi, and J. Roudet, "A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers," IEEE transaction on Power Electronics, Vol. 23, No.5, pp. 2428-2442, Sep. 2008. https://doi.org/10.1109/TPEL.2008.2002055
  13. S. Khomfoit, and L. M. Tolbert, "Fault detection and reconfiguration technique for cascaded H-bridge 11-level inverter drives operating under faulty condition," in Proc. Power Electronics and Drive Systems, PEDS'07,pp. 1035–1042, Nov. 2007.
  14. B. Badrzadeh, K. S. Smith, and R. C. Wilson, "Alternatives for highpower power electronic converters, switching devices and electric machines for very large wind farms: A technological and market assessment," European Wind Energy Conference, 2009.
  15. S. Gunturi and D. Schneider, "On the Operation of a Press Pack IGBT Module Under Short Circuit Conditions," IEEE transaction on Advanced Packaging, vol. 29, no. 3, pp. 433-440, Aug. 2006. https://doi.org/10.1109/TADVP.2006.875090
  16. R. Schlegel, E. Herr, and F. Richter, "Reliability of non-Hermetic pressure contact IGBT modules," Microelectron. Rel., vol. 41, pp.1689–1694, Oct. 2001. https://doi.org/10.1016/S0026-2714(01)00193-7
  17. W. Song and A.Q. Huang, "Control strategy for fault-tolerant cascaded multilevel converter based STATCOM," in Proc. Applied Power Electronics Conference, APEC 2007, pp. 1073 – 1076, Feb. /Mar. 2007.
  18. V. John, B.-S. Suh, and T.A. Lipo, "Fast clamped short circuit protection of IGBTs," IEEE-IAS Transactions on Industry Applications, Vol. 35, No. 2, pp. 477-486, Mar./Apr. 1999. https://doi.org/10.1109/28.753644
  19. F. Huang, and F. Flett, "IGBT fault protection based on di/dt feedback control" in Proc. IEEE PESC conf., pp. 1478-1484, Jun. 2007.

Cited by

  1. Analysis of the Internal Electrical Characteristics of Electronic Power Transformers vol.13, pp.5, 2013, https://doi.org/10.6113/JPE.2013.13.5.746
  2. Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems vol.10, pp.5, 2010, https://doi.org/10.6113/JPE.2010.10.5.572
  3. Fault-Tolerant Operation of Three-Phase Cascaded H-Bridge Converters Using an Auxiliary Module vol.64, pp.2, 2017, https://doi.org/10.1109/TIE.2016.2613983
  4. A New Single-Phase Asymmetrical Cascaded Multilevel DC-Link Inverter vol.16, pp.4, 2016, https://doi.org/10.6113/JPE.2016.16.4.1504
  5. Single-Stage Double-Buck Topologies with High Power Factor vol.11, pp.5, 2011, https://doi.org/10.6113/JPE.2011.11.5.655
  6. Modified space vector modulation for fault-tolerant operation of multilevel cascaded H-bridge inverters vol.6, pp.4, 2013, https://doi.org/10.1049/iet-pel.2012.0543
  7. Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization vol.14, pp.5, 2014, https://doi.org/10.6113/JPE.2014.14.5.946