Study on Evaluation Analysis on Thermal Performance of Window Using A. S. Lab.(Artificial Solar Laboratory)

인공태양실험실(A. S. Lab.)을 활용한 창호의 열성능 평가에 관한 연구

  • Received : 2010.08.03
  • Published : 2010.11.10

Abstract

Recently residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. Along this the increased size and transparency of window as well as light surface caused by high stories lowers the heat shield efficiency of building. Since glass that constitutes building surface has low heat efficiency, it aggravates heat loss of all building considerably, thereby resulting in extreme heating load and cooling load in the country where temperature varies much in summer and winter. The research will check whether experiment can be effectively done by overcoming the limit of existing artificial solar laboratory constructed in the country and properly adjusting controlled variables with simplified function through construction of this experimental set.

Keywords

References

  1. Zollner, A., Winter, E. R. F. and Viskanta, R., 2002, Experimental studies of combined heat transfer in turbulent mixed convection fluid flows in double-skin-facades, International Journal of Heat and Mass Transfer, Vol. 45, No. 22, pp. 4401-4408. https://doi.org/10.1016/S0017-9310(02)00160-6
  2. Lee, K. H., Yoon, Y. S., Jang, D. H., Kang, K. N. and Lee, E. S., 2008, A study on construction of artificial climate control chamber for valuation of ventilation performance at(high-rise) buildings, Architectural Institute of Korea, autumn Annual Conference, pp. 635-638.
  3. Park, C. Y., Lee, K. H., Yoon, Y. S. and Choi, C. H., 2005, A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period, Korean Journal of the Solar Energy Society(KSES), Vol. 27, No. 2, pp. 111-119.
  4. Elisabeth Gratia and Andre' De Herde, 2007, Are energy consumptions decreased with the addition of a double-skin, Energy and Buildings, Vol. 39, No. 5, pp. 605-619. https://doi.org/10.1016/j.enbuild.2006.10.002
  5. Ikbal Cetiner, Ertan Ozkan, 2005, An approach for the evaluation of energy and cost efficiency of glass facade, Energy and Buildings, Vol. 37, No. 6, pp. 673-684. https://doi.org/10.1016/j.enbuild.2004.10.007
  6. Valentina Serra, Fabio Zanghirella and Marco Perino, 2010, Experimental evaluation of a climate facade:Energy efficiency and thermal comfort performance, Energy and Buildings, Vol. 42, No. 1, pp. 50-62. https://doi.org/10.1016/j.enbuild.2009.07.010