References
- P. Mortier, 1893, "Fan or Blowing Apparatus", U. S. Patent No. 507445.
- S. Murata and K. Nishihara, 1976, "An Experimental Study of Cross Flow Fan (1st Report, Effects of Housing Geometry on the Fan Performance)", Bulletin of the JSME, Vol. 19, No. 129, pp. 314-321. https://doi.org/10.1299/jsme1958.19.314
- H. Ilberg and W. Z. Sadeh, 1965, "Flow Theory and Performance of Tangential Fans", Proc. Instn. Mech. Engrs., Vol. 180, Part 1, No. 19, pp. 481-491. https://doi.org/10.1243/PIME_PROC_1965_180_034_02
- A. M. Porter and E. Markland, 1970, "A Study of the Cross Flow Fan", Journal Mechanical Engineering Science, Vol. 12, No. 6, pp. 421-431. https://doi.org/10.1243/JMES_JOUR_1970_012_071_02
- L. Preszler and T. Lajos, 1972, "Experiments for the Development of the Tangential Flow Fan", Proc. of the 4th Conference on Fluid Machinery, Budapest, Akademiai Kiado, pp. 1071-1082.
- A. Morita et al,, 1986, "Development of Wall-Mounted Type Residential Air Conditioner", Technical Review, Mitzubishi Heavy Industries Ltd., pp. 263-268.
- A. Toffolo, A. Lazzaretto and A. D. Martegani, 2004, "An Experimental Investigation of the Flow Field Pattern within the Impeller of a Cross-Flow Fan", Experimental Thermal and Fluid Science, article in press.
- H. Tsurusaki et al., 1993, "Study of Cross-Flow Fan Internal Flow by Flow Visualization (1st Report, Discussion of Measured Results by Particle-Tracking Velocimetry)", Trans. of JSME (Series B), Vol. 59, No. 568, pp. 3743-3748. https://doi.org/10.1299/kikaib.59.3743
- H. M. Koo, 1999, "An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner", Trans. of KSME (Part B), Vol. 23, No. 6, pp. 695-702.
- Y. Cho, Y. J. Moon and S. W. Jin, 1999, "Numerical Prediction of Cross-Flow Fan Per- formance and Noise Characteristics by Unsteady Flow Computations)", Proc. of KSME Spring Annual Meeting, pp. 417-422, KSME 99S234.
- M. K. Chung, S. W. Jin and K. S. Cho, 2001, "A Numerical Analysis of Split Type RAC Indoor Unit and Its Application to Design", Proc. of SAREK 2001 Summer Annual Meeting, pp. 1038-1042, 2001-S-177.
- N. K. Hur, W. Kim and S. H. Kang, 1999, "A Numerical Study on Flow through a Cross Flow Fan : Effect of Blade Shapes on Fan Per- formance", J. of Fluid Machinery, Vol. 2, No. 1, pp. 96-102.
- 이형건, 박형구, 2002, "횡류팬 내부의 유동해석", 한국전산유체공학회 2002년도 춘계학술대회논문집, pp. 65-70.
- 전용두, 이종수, 2002, "횡류팬 유로최적화를 위한 수치실험", 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집, pp. 147-151.
- 김동원, 이준화, 박성관, 김윤제, 2002, "수치해석적기법을 이용한 횡류홴 성능평가", 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집, pp.152-157.
- D. W. Kim, H. S. Kim, S. K. Park and Y. J. Kim, 2005, "Analysis on Flow Fields and Performance of a Cross-Flow Fan with Various Setting Angles of a Stabilizer", J. of Computa- tional Fluids Engineering, Vol. 10, No. 1, pp. 107-112.
- K. S. Yang, 1995, "Improvement on Large-Eddy Simulation Technique of Turbulent Flow", Trans. of KSME, Vol. 19, No. 7, pp. 1691-1701.
- D. S. Jang, Y. W. Lee, D. H. Doh, D. S. Bae and N. S. Kim, 2000, "Numerical Analysis on Flow Field Around a Bluff Body by LES(I)", J. of KSPSE, Vol. 4, No. 3, pp. 40-47.
- J. K. Kim and K. J. Jeong, 2005, "Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner", J. of KSPSE, Vol. 9, No. 3, pp. 33-38.
- J. K. Kim, 2005, "Experimental Study on the Aerodynamic Performance Characteristics for Various Design Factors in the Maximum Flowrate range of a Cross-Flow Fan", J. of KSPSE, Vol. 9, No. 3, pp. 44-49.
- J. K. Kim, 2005, "Experimental Study on the Surface Pressure Characteristics of a Rear-Guider for the Various Design Factors of a Cross-Flow Fan", J. of KSPSE, Vol. 9, No. 3, pp. 50-57.
- SC/Tetra(Version 7), 2007, User's Guide, Soft- ware Cradle Co., Ltd.