Load Resistance Mechanism and Behavior Characteristics of MRS Continuous Joints

MRS 연속단 접합부의 구조상세에 따른 하중저항 메커니즘과 거동 특성

  • Received : 2009.10.30
  • Accepted : 2010.02.05
  • Published : 2010.04.30

Abstract

The purpose of study is to investigate the load resistance mechanism of MRS continuous joint designed with different details. Six full-scale specimens, which could simulate the negative moment region of the 8 m long MRS system, were prepared to evaluate the structural performance of the continuous joint. According to the experimental results, all specimens which include the specimen with dapped ends designed by loads at the construction stage were failed in a flexural manner and showed the load carrying capacity over the nominal flexural strength. Therefore it is recommended that the dapped ends for MRS continuous joints be designed for the loads of the construction stage. And the shear key, which was installed on the top of rib for MRS slab, helps the enhancement of strength and especially deformation capacity.

이 연구는 댑단부 설계방법, 덧침 콘크리트 접합면의 상태, 댑단부의 형상 등의 구조상세가 MRS 연속단 접합부의 하중저항 메커니즘과 거동 특성에 미치는 영향을 평가하였다. 댑단부의 전단설계를 위한 계수하중으로서 고정하중과 활하중을 고려한 실험체와 고정하중만을 대상으로 설계한 실험체는 모두 접합부의 연성적인 휨파괴를 보여주었다. 따라서 MRS 연속단 접합부의 댑단부는 시공단계에 따라 변화하는 응력상태에 맞게 댑단부의 전단설계를 한다면 실제 사용상태의 하중은 연속단의 휨저항 메커니즘에 의해 저항할 수 있다고 판단된다. 또한 접합면의 거칠기는 MRS 연속단 접합부의 휨강도에 큰 영향을 미치지 않는 것으로 나타났지만 MRS 단부에 전단키를 설치한 구조상세는 변형능력을 향상시키는 결과를 보여주었다.

Keywords

References

  1. 김상연, 이범식, 박광열, 이성복, 윤영호, “외국의 PC 주차장 건물 현황과 국내 아파트 지하주차장의 PC공법 적용 방안,” 콘크리트학회 학회지, 20권, 1호, 2008, pp. 34-40.
  2. PCI Industry Handbook Committee, PCI Design Handbook-Precast Prestressed Concrete, 6th Edition, Precast/Prestressed Concrete Institute, Chicago, IL, 2005, 736 pp.
  3. Mattock, A. H. and Theryo, T., Strength of Members with Dapped Eeds, PCI, Research Project No. 6, 1986, 218 pp.
  4. プレハブ建築協會, プレキャスト建築技術集成 第4編 RPCの設計, 2003, 354 pp.
  5. 삼성물산(주) 건설부문, “일방향 PC 장선 슬래브의 접합 상세 개발 및 구조성능 평가에 관한 연구,” 연구보고서, 삼성물산(주) 건설부문, 2007, 156 pp.
  6. 삼성물산(주) 건설부문, “MRS 구조시스템의 접합상세 개발 및 구조성능 평가에 관한 연구,” 연구보고서, 삼성물산(주) 건설부문, 2008, 337 pp.
  7. 한국콘크리트학회, 콘크리트구조설계기준 해설, 한국콘크리트학회, 2008, 523 pp.
  8. ACI Committee 318, Uilding Code Requirements for Structural Concrete and Commentary (ACI 318M-05), American Concrete Institute, Michigan, 2008, 467 pp.
  9. PCA, Notes on ACI 318-02 Building Code Requirements for Structural Concrete, American Concrete Institute, Michigan, 2008, 1026 pp.

Cited by

  1. Effect of Foaming Agent Content on the Apparent Density and Compressive Strength of Lightweight Geopolymers vol.4, pp.4, 2016, https://doi.org/10.14190/JRCR.2016.4.4.363
  2. Nonlinear Analysis for Negative Moment Distribution of MRS Slab End Joints vol.23, pp.2, 2011, https://doi.org/10.4334/JKCI.2011.23.2.177