DOI QR코드

DOI QR Code

3D Gait Analysis of Limb Salvage Patients with Osteoarticular Knee Allograft Reconstruction

슬관절 동종골을 이용한 사지 구제수술 환자의 3차원 보행분석

  • Jang, Ik-Gyu (National cancer center, Biomedical Engineering Branch) ;
  • Park, Hong-Seong (Kangwon National University College of IT, Department of Electronic & Telecommunication) ;
  • Nam, Kyoung-Won (National cancer center, Biomedical Engineering Branch) ;
  • Hong, Man-Bok (National cancer center, Biomedical Engineering Branch) ;
  • Kim, Soo-Hyun (National cancer center, Biomedical Engineering Branch) ;
  • Kim, Han-Soo (Seoul National University College of Medicine, Department of Orthopaedic Surgery) ;
  • Kang, Hyun-Guy (National cancer center, Orthopaedic Oncology Clinic) ;
  • Kim, Kwang-Gi (National cancer center, Biomedical Engineering Branch)
  • 장익규 (국립암센터 실용화 연구부 의공학 연구과) ;
  • 박홍성 (강원대학교 IT특성화대학 전자통신공학과) ;
  • 남경원 (국립암센터 실용화 연구부 의공학 연구과) ;
  • 홍만복 (국립암센터 실용화 연구부 의공학 연구과) ;
  • 김수현 (국립암센터 실용화 연구부 의공학 연구과) ;
  • 김한수 (서울대학병원 정형외과) ;
  • 강현귀 (국립암센터 특수암센터, 골연부종양클리닉) ;
  • 김광기 (국립암센터 실용화 연구부 의공학 연구과)
  • Received : 2009.10.08
  • Accepted : 2010.01.25
  • Published : 2010.02.28

Abstract

This paper presents the three dimensional gait analysis of the patients with osteoarticular knee allograft reconstruction. The gait analysis has been performed in some medical fields such as orthopedics and neurosurgery for the purpose of the rehabilitation of patients. However, to the author's knowledge, the analysis of gait for the patients with osteoarticular knee allograft reconstruction caused by tumor has not been reported. In this work, In this work, we confirmed the validity of this method by analyzing 50 samples per one gait cycle obtained from each of 3 patients and 3 normal persons. The motion capture was performed using six infrared cameras. The symmetry and stability of the gait patterns are investigated (patients' r=0.39, p<0.05, normal persons' r=0.65, p<0.05) respectively using the correlation coefficients and the standard deviations of the joint angles of the left and right legs. It also would be applied to the comparison analysis where artificial knee joint is transplanted.

Keywords

References

  1. L. Jeys, and R. Grimer, "The long-term risks of infection and amputation with limb salvage surgery using endoprostheses.," Recent Results Cancer Research, vol. 179, pp. 75-84, 2008.12.28. sunday, 2009.
  2. K. Moore, and T. Persaud, Use of Distal Femoral Osteoarticular Allografts in Limb Salvage Surgery: WB Saunders Company, 1993.
  3. H.G. Lim, J.H. Kim, and S. A. Ryu, S.C. Park, Y.S. Lee "A Study of Measurement on Reach of Motion using a 3-D Motion Analysis System for Korean Adults(20's and 30's)," Korean Journal of Sport Biomechanics, vol. 8, no. 2, pp. 1-20, 1998.
  4. N. V. Boulgouris, D. Hatzinakos, and K. N. Plataniotis, "Gait recognition: a challenging signal processing technology for biometric identification," Signal Processing Magazine, IEEE, vol. 22, no. 6, pp. 78-90, 2005. https://doi.org/10.1109/MSP.2005.1550191
  5. D. J. Kim, T. B. Ryu, and H. S. Choi, S.M. Kwon, M.K. Chung, "Development of Gait Diagnosis Supporting System using Korean Normal Gait Data," Journal of the Korean Institute of Industrial Engineers, vol. 33, no. 4, pp. 480-486, 2007.
  6. G. R. TACK, Y. M. Han, and J. H. Yi, J. S. Choi, Y. T. Lim, J. H. Jun, S. K. Park, S. H. Park, S. Darren, "Relationship between Walking Speed and Smoothness of Movement," Korean Journal of Sport Biomechanics, vol. 16, no. 1, pp. 11-17, 2006. https://doi.org/10.5103/KJSB.2006.16.1.011
  7. C.Y. Chung, M. C. Lee, and T. G. Kim, Y.W. Moon, S.T. Lim, S.C. Seong, "Gait Analysis after Total Knee Arthroplasty," J. of Korean Orthop. Assoc., vol. 32, no. 5, pp. 1290-1301, 1997.
  8. C.Y. Chung, M.S. Park, and T. J. Cho, I.H. Choi, W.J. Yoo, J.Y. Kim, "Three Dimensional Gait Analysis in Normal Korean -A Preliminary Report-," J. of Korean Orthop. Assoc., vol. 40, no. 1, pp. 83-88, 2005.
  9. J. H. Park, K. Son, and K. H. Kim, "Chaos Analysis of Major Joint Motions for Young Males During Walking," The journal of The Korean Society of mechanical Engineers A, vol. 31, no. 8, pp. 889-895, 2007. https://doi.org/10.3795/KSME-A.2007.31.8.889
  10. W.S. Cho, Y.S. Youm, and B. S. Yang, "The Causes of Revision Total Knee Arthroplasty," J. of Korean Orthop. Assoc., vol. 42, no. 2, pp. 216-220, 2007. https://doi.org/10.4055/jkoa.2007.42.2.216
  11. C.H. Chun, K.M. Kim, and H. J. K. S.H. Kweon, K.J. Jeong, "Revision Total Knee Arthroplasty using NexGen LCCK with Allograft," J. of Korean Orthop. Assoc., vol. 43, no. 6, pp. 728-737, 2008. https://doi.org/10.4055/jkoa.2008.43.6.728