DOI QR코드

DOI QR Code

Automation of urine dipstick test by simultaneous scanning : A pilot study

요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구

  • Lee, Sang-Bong (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Choi, Seong-Su (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Lee, In-Kwang (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Han, Jeong-Su (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Kim, Wan-Seok (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Kim, Wun-Jae (Department of Urology, Chungbuk National University) ;
  • Cha, Eun-Jong (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center) ;
  • Kim, Kyung-Ah (Department of Biomedical Engineering, Chungbuk National University, BK21 Chungbuk Biomedical Science Center)
  • 이상봉 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 최성수 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 이인광 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 한정수 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 김완석 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 김원재 (충북대학교 의대 비뇨기과학교실) ;
  • 차은종 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단) ;
  • 김경아 (충북대학교 의대 의공학교실, 충북대학교 의학전문대학원, BK21 차세대 선도 의과학 전문인력 양성사업단)
  • Received : 2010.01.19
  • Accepted : 2010.03.12
  • Published : 2010.05.31

Abstract

Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.

Keywords

References

  1. 최순덕, 조한준, 김기혁, “Diagnostic value of dipastick urinalysis as a screening test for urinary tract infection”, J. Korea Acad Fam Med, pp. 772-781, 2000.
  2. L. E. Armstrong, C. M. Maresh, J. W. Castellani, M. F. Bereron, R. W. Kenefick, K. E. La Gassee, and D. Riebe, “Urinary indioes of hydration status”, Int. J. Sport Nutr, vol. 4, pp. 265-279, 1994. https://doi.org/10.1123/ijsn.4.3.265
  3. 이강욱, “Routine urinalysis in renal diseases”, J. Korean Acad Farn Med, vol. 24, no. 2, pp. 265-279, 2003.
  4. C. G. Roehrborn, G. Bartsch, R. Kirby, G. Andriole, P. Boyle, and J. de la Rosette. “Guidelines for the diagnosis and treatment of benign prostatic hyperplasia: a comparative”, international overview. Urology, vol. 58, pp. 642-650, 2001
  5. J. B. Henry, R. B. Lauzon, and G. B. Schumann. “Basic examination of urine. In: J. B. Henry, ed, Clinical diagnosis and management by laboratory methods”, 19th ed. Philadelphia, W. B. Saunders, 411, 1994.
  6. L. E. Armstrong, J. A. Soto, F. T. Hacker, D. J. Casa, S. A. Kavouras, and C. M. Maresh, “Urinary Indices During Dehydration, Exercise, and Rehydration”, Int. J. Sport Nutr., vol. 8, pp. 345-355, 1998. https://doi.org/10.1123/ijsn.8.4.345
  7. 전계록, 김기련, 예수영, 김철한, 정도운, 조진호, “요분석 시스템의 분류기 설계에 관한 연구”, J. Biomed. Eng. Res., 제24권, 제3호, pp. 193-201, 2003.
  8. 예수영, 전용욱, 정도운, 전계록, 노정훈, “저가형요분석 시스템의 다중 광 검출 모듈 개발”, 센서학회지, 제17권, 제5호, pp. 387-395. 2008.
  9. 김기련, 예수영, 손정만, 김철한, 정도운, 이승진, 장용훈, 전계록, “색 보정 및 색 좌표 변환 기법을 이용한 요분석 시스템의 구현”, J. Biomed. Eng. Res., 제24권, 제3호, pp. 183-192, 2003.
  10. 조용현, “스트립의 컬러영상을 이용한 요 분석기에 관한 연구”, 퍼지 및 지능시스템학회 논문지, 제17권, 제7호, pp. 919-923, 2007. https://doi.org/10.5391/JKIIS.2007.17.7.919
  11. http://www.clinic-clinic.com/prblm/Lab/urinaly-sis.asp.
  12. “Uv-visible spectrophotometer”, http://cheric.org/ippage/d/ipdata/2004/03/file.
  13. “근적외선 분광법의 이해(1)”, http://www.sjint.co.kr/up-file.
  14. 김혜란, 이정녀, “국산 요분석기 URISCAN S-300과 Miditron M, Clinitek 100의 요검사 성적의 비교”, 인제의학, 제23권, 제2권, pp. 713-719, 2002.