The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Keywords

Acknowledgement

Supported by : 한국에너지기술평가원(KETEP)

References

  1. 김희동, "발전기 고정자 권선의 절연열화 메카니즘 분석", 전기전자재료학회논문지, Vol. 15, No. 2, pp. 119-126, 2002.
  2. R. Morin, R. Bartnikas and P. Menard, "A Three-Phase Multi-Stress Accelerated Electrical Aging Test Facility for Stator Bars", IEEE Trans. on Electrical Conversion, Vol. 15, No. 2, pp. 149-156, 2000. https://doi.org/10.1109/60.866992
  3. 김희동, 김병한 "수력발전기 고정자 권선의 운전중 부분방전 특성", 전기학회논문지, Vol. 55C, No. 4, pp. 172-177, 2006.
  4. W. McDermid and J. C. Bromley, "Experience with Directional Couplers for Partial Discharge Measurements on Rotating Machines in Operation", IEEE Trans. on Energy Conversion, Vol. 14, No. 2, pp. 175-181, 1999. https://doi.org/10.1109/60.766981
  5. H. Yoshida and K. Umemoto, "Insulation Diagnosis for Rotating Machine Insulation", IEEE Trans. on Electrical Insulation, Vol. EI-21, No. 6, pp. 1021-1025, 1986. https://doi.org/10.1109/TEI.1986.349018
  6. 주영호외 6명, "발전기 정지중 진단 및 수명평가 기술개발(1단계 보고서)", 지식경제부, 2009.
  7. G. C. Stone, T. E. Goodeve, H. G. Sedding and W. McDermid, "Unusual PD Pulse Phase Distributions in Operating Rotating Machines", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 2, No. 4, pp. 567-577, 1995. https://doi.org/10.1109/94.407022
  8. G. C. Stone, Partial Discharge Seminar, Iris Power Engineering Inc., Vol. 1, pp. 56-78, 2005.
  9. Hee-Dong Kim and Chung-Hyo Kim, "Stator Insulation Quality Assessment for High Voltage Motors Based on Probability Distributions", Journal of Electrical Engineering & Technology, Vol. 3, No. 4, pp. 571-575, 2008. https://doi.org/10.5370/JEET.2008.3.4.571
  10. Y. Takikawa, T. Watanabe, H. Kamiya, M. Sukeda, I. Nanai and H. Miyao, "Technology for Preventive Maintenance of Turbine Generators", Hitachi Review, Vol. 72, No. 8, pp. 35-42, 1990.
  11. IEEE Std 1484-2000, IEEE Trial-Use Guide to the Measurement of Partial Discharges in Rotating Machinery
  12. G. C. Stone and V. Warren, "Objective Methods to Interpret Partial-Discharge Data on Rotating-Machine Stator Windings", IEEE Trans. on Industry Applications, Vol. 42, No.1, pp. 195-200, 2006. https://doi.org/10.1109/TIA.2005.861273
  13. G. Griffith, S. Tucker, J. Milsom and G. C. Stone, "Problems "With Modern Air-Cooled Generator Stator Winding Insulation", IEEE Electrical Insulation Magazine, Vol. 16, No.2, pp. 6-10, 2000.
  14. C. Hudon and M. Belec, "Partial Discharge Signal Interpretation for Generator Diagnostics", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 12, No.2, pp. 297-319, 2005. https://doi.org/10.1109/TDEI.2005.1430399
  15. Hee-Dong Kim and Young-Ho Ju, "Comparison of Off-Line and On-Line Partial Discharge for Large Motors", IEEE International Symposium on Electrical Insulation, pp. 27-30, 2002.