DOI QR코드

DOI QR Code

Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics

초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구

  • Received : 2010.05.04
  • Accepted : 2010.08.30
  • Published : 2010.10.01

Abstract

The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

Keywords

References

  1. 정종한, 김희제, "최신 펄스공학 및 응용", 내하출판사, 2003, pp. 2-3
  2. S. T. Pai and Qi Zhang, "Introduction to high Power Pulse Technology", World Scientific, 1995, ch. 1.2.
  3. W. J. Carey and J. R. Mayes, "Marx generator design and performance", Proc. of the 25th International Power Modulator Symposium, Hollywood, pp. 625-628, 2002
  4. 박승록, 정석환, 김진규, 문재덕, "Marx 펄스발생기를 응용한 소형 고전압 급준 펄스 발생장치", 전기학회논문지 50,2-C(2001.2) pp.72-78 1975-8359
  5. Ming Chang Wang, Gun-Sik Park, "An Improvement of High Voltage Power Supply for Pseudospark Discharge", Int. J. Infrared and Millimeter Waves, 18(6), 1187(1997) https://doi.org/10.1007/BF02678226
  6. L. K. Heffernan, R. D. Curry, K. F. McDonald, ""A Fast, 3 MV Marx Generator for Megavolt Oil Switch Testing with an Integrated Abramyan Network Design"", 15th IEEE Pulsed Power Conf., pp.596-599, 2005.
  7. R. Beverly III, R. Campbell, "Aqueous-electrolyte resistors for pulsed power applications", Review of Scientific Instruments, vol. 66, pp. 5625-5629, 1995 https://doi.org/10.1063/1.1146029
  8. L. G. Christophorou, L. A. Pinnaduwage, "Basic Physics of Gaseous Dielectrics", IEEE Trans. on electrical insulation, Vol. 25, No. 1, pp.55-74, 1990 https://doi.org/10.1109/14.45234
  9. H Itoh , M Shimozuma , H Tagashira and S Sakamoto, "Measurement of the effective ionisation coefficient and the static breakdown voltage in SF6 and nitrogen mixtures" J. Phys. D: Appl. Phys., Vol. 12, No. 12, pp 2167-2172, 1979 https://doi.org/10.1088/0022-3727/12/12/018
  10. B. CADILHON, L. PECASTAING, T. REESS, A. GIBERT, "Low stray inductance structure to improve the rise-time of a Marx generator", IET Electric Power Applications , Volume 2 Issue 4, pp. 248-255, 2008 https://doi.org/10.1049/iet-epa:20070250
  11. Laurent Pecastaing, Jean Paillol, Thierry Reess, Alain Gibert, and Pierre Domens, "Very fast rise-time short pulse high voltage generator", IEEE Trans. Plasma Sci., 2006, 34, (5, Part 1), pp. 1822-831. https://doi.org/10.1109/TPS.2006.883346
  12. M M Kekez, J Liu, " A 60 Joule, 600 kV, 500 ps risetime, 60 ns pulse width Marx generator", Nat. Res. Council of Canada, Ottawa, Ont., Canada
  13. Gennady A.Mesyats, "Pulsed power", Springer, 2005, ch. 12.
  14. J. Mankowski, J. Dickens, M. Kristiansen, "High Voltage Subnanosecond Breakdown," IEEE Transactions on Plasma Science 26, 1998, pp 874-880. https://doi.org/10.1109/27.700858