Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker

영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구

  • Kim, Jong-Min (Department of Radiation Oncology, Asan Medical Center) ;
  • Kim, Dae-Sup (Department of Radiation Oncology, Asan Medical Center) ;
  • Back, Geum-Mun (Department of Radiation Oncology, Asan Medical Center) ;
  • Kang, Tae-Yeong (Department of Radiation Oncology, Asan Medical Center) ;
  • Hong, Dong-Ki (Department of Radiation Oncology, Asan Medical Center) ;
  • Yun, Hwa-Yong (Department of Radiation Oncology, Asan Medical Center) ;
  • Kwon, Kyeong-Tae (Department of Radiation Oncology, Asan Medical Center)
  • 김종민 (서울아산병원 방사선종양학과) ;
  • 김대섭 (서울아산병원 방사선종양학과) ;
  • 백금문 (서울아산병원 방사선종양학과) ;
  • 강태영 (서울아산병원 방사선종양학과) ;
  • 홍동기 (서울아산병원 방사선종양학과) ;
  • 윤화룡 (서울아산병원 방사선종양학과) ;
  • 권경태 (서울아산병원 방사선종양학과)
  • Received : 2009.09.16
  • Accepted : 2009.12.20
  • Published : 2010.03.31

Abstract

Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

목 적: Fiducial marker를 이용하여 움직이는 장기인 간암의 영상유도 방사선 치료 시 fiducial marker에서 발생하는 artifact의 영향에 대하여 알아보고자 한다. 대상 및 방법: 영상 유도 시스템과 CT simulator를 사용하여 고정된 fiducial marker의 artifact 크기 측정, 움직이는 fiducial marker 궤적의 길이 측정과 2차원 정합과 3차원 정합을 각각 시행하였으며, 이때 couch의 좌표 이동 값을 분석하였다. 결 과: 고정된 3.00 mm 크기의 fiducial marker artifact 크기 측정 결과 기준 CT 슬라이스 두께 1.25, 2.50, 5.00, 10.00 mm에서 CT 4.90, 8.10, 12.90, 19.70 mm, 온 보드 영상장치 5.60, 10.60, 14.70, 29.40 mm로 측정되었고, 40.00 mm로 움직이는 fiducial marker 궤적의 길이를 측정한 결과 CT 42.00, 43.10, 46.50 mm, 온 보드 영상장치 43.40, 46.0, 49.30 mm로 측정되었다. 2차원 정합과 3차원 정합 사이에 1.00, 2.00, 8.00 mm의 좌표 이동이 발생하였다. 결 론: Fiducial marker를 이용하여 영상 유도 방사선 치료를 시행 할 때 fiducial marker에서 발생하는 artifact를 고려하여 slice thickness를 2.50 mm 이하로 설정하는 것이 치료 오차를 최소화 할 수 있는 방법이라 생각한다.