DOI QR코드

DOI QR Code

An Electrochemical Evaluation on the Corrosion Property of Metallizing Film

용사 도막의 내식성에 관한 전기화학적 평가

  • 문경만 (한국해양대학교 조선기자재공학부) ;
  • 신중하 (한국화학시험연구원) ;
  • 이명훈 (한국해양대학교 해사대학 기관시스템공학부) ;
  • 이성렬 (한국해양대학교 조선기자재공학부) ;
  • 김윤해 (한국해양대학교 공대 조선기자재공학부)
  • Received : 2010.05.04
  • Accepted : 2010.07.09
  • Published : 2010.07.31

Abstract

There are many surface protection methods for numerous steel structures being used under severely corrosive environment, one of them, metallizing(thermal spray) is a available protection method which is comparatively and recently developed for surrface protection of various steel structures. However coating film obtained by spraying is to be needed increasingly more good corrosion resistance due to accelerating of environmental contamination. In this study, coating films(DFT:$200{\mu}m$) are performed with arc spray by wire metal and their types of films are pure zinc, pure aluminum, alloy film(Al:Zn=85:15) and alloy film(Al:Zn=95:5). And corrosion resistance of their films was investigated with electrochemical methods in seawater solution. Pure aluminum film showed a relatively somewhat good corrosion resistance compared to among those of other films and alloy films also showed a good corrosion resistance compared to pure zinc film. Especially it was observed that pure aluminum film showed a comparatively good corrosion resistance than that of alloy film named as galvarium spray(Al:Zn=85:15) in seawater solution. Morphology of corroded surface of pure zinc film appeared the pattern like intergranlar corrosion, however films of pure aluminum and alloy metal showed a general corrosion pattern.

가혹한 부식환경 하에 사용되어 지고 있는 다양한 강구조물에 대해서 많은 표면방식법이 있다. 그 중의 한방법인 용사는 다양한 강구조물의 표면방식을 위하여 비교적 최근에 개발된 유용한 방식법이다. 그러나 용사피막도 환경오염의 가속화에 따라 점차 더욱 좋은 내식성을 필요로 하고 있다. 본 연구에서는 아아크 용사에 의해서 도막두께 $200{\mu}m$의 피막을 만들었으며, 피막의 종류는 순 아연,순 알류미늄, 합금피막(Al:Zn=85:15) 및 (Al:Zn=95:5)의 합금피막이었다. 그리고 이들 피막의 내식성을 해수용액에서 전기화학적인 방법으로 고찰 하였다. 순 알류미늄 피막은 다른 피막에 비해서 비교적 상당히 좋은 내식성을 보였다. 그리고 합금피막도 역시 순 아연피막에 비해서 좋은 내식성을 보였다. 특히 순 알류미늄 피막은 갈바륨 용사라고 알려진 합금피막(Al:Zn=85:15)보다 해수용액에서 내식성이 상대적으로 좋았음이 관찰되었다. 순 아연의 부식된 표면양상은 입게부식의 형태를 나타내었으나 순 알류미늄과 합금피막은 균일부식의 형태를 나타내었다.

Keywords

References

  1. J-P. hirvonen, P. Kauppinen and P. Andersson, "Elastic dry sliding characteristics of HVOF-sprayed $AL_2O_3$ and $Al_2O_3-TiO_2 $coating", Preceeding of the 1993 National Thermal Spray Conference, pp. 475-480, 1993.
  2. Denny A. Jones, "Principles and prevention of corrosion", Maxwell Macmillian International Publishing Group, New York, USA, p. 398, 1991.
  3. The Techonlogy Center of the Coastal Development, Corrosion Control Manual of Harbor Steel Structure, Tokyo, Jappen, p. 21, 1987.
  4. W. von Baeckmann, "Handbook of Cathodic Corrosion Protection", Guef Publishing Company, Houston Texas, USA p.180, 1997.
  5. Mars G. Fontana etc., "Corrosion Engineering", McGraw-Hill, Inc, New Jersey, USA p.39, 1978.
  6. R. F. Bunshah, "Deposition technologies for films and coatings", Noyes Pub., Ch. 1, pp. 234-239, 1982.
  7. K. M. Moon, H. R. Cho, T. Y. Kang, M. H. Lee and Y. U. Kim, "An electrochemical study on the corrosion resistance improvement of galvanizing steel by dipping to solution with inhibitor", Journal of the Korean Society of Marine Engineering, vol. 31, no. 2, pp. 173-181, 2007. https://doi.org/10.5916/jkosme.2007.31.2.173
  8. H. S, Ingham and A. P Shepart, Flame Spray Handbook, Metco Inc., vol. III, 1985.
  9. M. H Regina, Pombo Rodriguez, and S. C. Roman, U. Schereiner, "Comparision of aluminum coatings deposited by flame spray and electric arc spray", Surface and Coating Technology. vol. 202, pp. 172-179, 2007. https://doi.org/10.1016/j.surfcoat.2007.05.067
  10. J. Wilden, H. Frank, and J. P. Bergman, "Process and microstructure simulation in thermal spraying", Surface and Coating Technology, Vol. 201, pp. 1962-1968, 2006. https://doi.org/10.1016/j.surfcoat.2006.04.059
  11. B.Gerard, "Application of thermal spraying in the automobile industry", Surface and Coationg Technology, vol. 201, pp. 2028-2031, 2006. https://doi.org/10.1016/j.surfcoat.2006.04.050
  12. W. B. Choi, L. Li, Y. Luzin, and H. J. Park, "Intergrated characterization of cold sprayed aluminum coatings", Acta Materialia, vol. 55, pp. 857-866, 2007. https://doi.org/10.1016/j.actamat.2006.09.006
  13. R. S. C. Pendes, S. C. Amico, and A. S. C. M. D'oliveira, "The effect of roughness and pre-heating of the substrate on the morphology of aluminum coatiogs deposided by thermal spraying", Surface and Coating Technology, vol. 200, pp. 3049-3055, 2006. https://doi.org/10.1016/j.surfcoat.2005.02.200
  14. J. V. Muylder and M. Pourbaix, Atlas of electrochemical equilibria in aqueous solution, Rergomon Press and Cebelcor, pp. 168-171, 406-409, 1966.

Cited by

  1. Study on the Immersion Corrosion Characteristics of Thermal Spray Coating for Sea Water Heat Exchanger vol.15, pp.1, 2014, https://doi.org/10.5762/KAIS.2014.15.1.32
  2. Electrochemical Characteristics of Arc Zn Thermal Spray Coating Layer in Sea Water vol.48, pp.6, 2015, https://doi.org/10.5695/JKISE.2015.48.6.343
  3. Cavitation Damage Behavior of Inconel 625 Coating Layer by Arc Thermal Spraying Method in Sea Water vol.48, pp.6, 2015, https://doi.org/10.5695/JKISE.2015.48.6.349
  4. An Electrochemical Evaluation of the Corrosion Properties of the Steel with the Type and the Thickness of Metallizing Coatings vol.25, pp.3, 2016, https://doi.org/10.7844/kirr.2016.25.3.55
  5. Cavitation Damage Characteristics of Al and Zn Arc Thermal Spray Coating Layers for Hull Structural Steel vol.49, pp.1, 2016, https://doi.org/10.5695/JKISE.2016.49.1.32
  6. Solution vol.49, pp.3, 2016, https://doi.org/10.5695/JKISE.2016.49.3.245
  7. 용사 도막의 내식성에 관한 전기화학적 평가 vol.9, pp.6, 2010, https://doi.org/10.14773/cst.2010.9.6.325
  8. 해수용 열교환기 적용을 위한 열분사 코팅의 부식 및 열전도 특성에 관한 실험적 연구 vol.14, pp.12, 2010, https://doi.org/10.5762/kais.2013.14.12.6098