Development of MRI Scanning Technique that is Comfortable for Patients with Anxiety Disorder

  • Cho, Moo-Seong (Department of Radiological Science, Gyeongsan University College) ;
  • Cho, Jae-Hwan (Department of Radiological Science, Gyeongsan University College) ;
  • Chang, Yong-Min (Department of Molecular Medicine and Radiology Kyungpook National University) ;
  • Cho, Yong-Ho (Department of Radiological Science, Catholic University of Daegu) ;
  • Zeon, Seok-Kil (Department of Nuclear Medicine Dongsan Hospital Keimyung University) ;
  • Dong, Kyung-Rae (Department of Radiological Technology, Gwangju Health College University) ;
  • Chung, Woon-Kwan (Department of Nuclear Engineering, Chosun University) ;
  • Lee, Hae-Kag (Department of Computer Science and Engineering, Soonchunhyang University) ;
  • Kim, Hyun-Ju (Department of Radiology, Soonchunhyang University Hospital) ;
  • Bae, Jae-Young (Department of Chemistry, Keimyung University) ;
  • Ahn, Jae-Ouk (Department of Medical IT Engineering, Soonchunhyang University) ;
  • Lee, Sang-Jeong (Department of Computer Science and Engineering, Soonchunhyang University)
  • 투고 : 2011.08.09
  • 심사 : 2011.10.25
  • 발행 : 2011.12.31

초록

The principal objective of this study was to develop a scanning technique that helps patients reduce their anxiety and relax their physical tension in the MRI system. The study targeted 10 healthy persons with no medical history of anxiety disorder in the past and with no current clinically diagnosed anxiety disorder, as well as 10 patients who were currently experiencing an anxiety disorder during the MRI scanning. The focusing board assembly was self-manufactured to conduct a clinical experiment via MRI scans. As a method to confirm the efficacy of the experiment, the bio meter was used to measure brainwaves from the study targets that were divided into the normal person group (A), who felt no anxiety in the MRI system and the experimental group, (B) who did experience anxiety in the MRI system. The two groups were compared between the cases in which the focusing board assembly was used and not used after measurements were conducted using the model MRI system and the bio meter. According to the comparison and analysis results, low measurements of the ${\alpha}$ wave indicate highly effective relaxation of tension. In the normal person group, the ${\alpha}$ wave measurement showed almost no difference between cases in which the focusing board assembly was used and cases in which it was not used. In the experimental group, the $\acute{a}$ wave measurements were lower in cases in which the focusing board assembly was used than in cases in which the focusing board assembly was not used; this was indicative of a profound relaxation effect.

키워드

참고문헌

  1. Statistics Korea, The Disease Death Cause Statistics, Seoul (2009).
  2. Centers for Disease Control and Prevention, The Brain Disease Consideration Condition, Atlanta (2008).
  3. J. D. Eastwood, M. H. Lev, M. Wintermark, C. Fitzek, D. P. Barboriak, D. M. Delong, T. Y. Lee, T. Azhari, M. Herzau, V. R. Chilukuri, and J. M. Provenzale, Am. J. Neuroradiol. 24, 1869 (2003).
  4. R. E. Latchaw, H. Yonas, G. J. Hunter, W. T. C. Yuh, T. Ueda, G. Sorensen, J. L. Sunshine, J. Biller, L. Wechsler, R. Higashida, and G. Hademenos, Stroke 34, 1084 (2003). https://doi.org/10.1161/01.STR.0000064840.99271.9E
  5. M. H. Lev, A. Z. Segal, J. Farkas, S. T. Hossain, C. Putman, G. J. Hunter, R. Budzik, G. J. Harris, F. S. Buonanno, M. A. Ezzeddine, Y. Chang, W. J. Koroshetz, R. G. Gonzalez, and L. H. Schwamm, Stroke 32, 2021 (2001). https://doi.org/10.1161/hs0901.095680
  6. L. M. Hamberg, G. J. Hunter, K. I. Maynard, C. Owen, P. P. Morris, C. M. Putman, C. Ogilvy, and R. G. Gonzalez, Am. J. Neuroradiol. 23, 1013 (2002).
  7. G. J. Hunter, H. M. Silvennoinen, L. M. Hamberg, W. J. Koroshetz, F. S. Buonanno, L. H. Schwamm, G. A. Rordorf, and R. G. Gonzalez, Radiology 227, 725 (2003). https://doi.org/10.1148/radiol.2273012169
  8. M. Wintermark, J. P. Thiran, P. Maeder, P. Schnyder, and R. Meuli, Am. J. Neuroradiol. 22, 905 (2001).
  9. A. M. Hakim, M. J. Hogan, and S. Carpenter, Stroke 23, 1138 (1992). https://doi.org/10.1161/01.STR.23.8.1138
  10. H. S. Friedman, N. Engl. J. Med. 334, 1405 (1996). https://doi.org/10.1056/NEJM199605233342114
  11. C. S. Kase, A. J. Furlan, L. R. Wechsler, R. T. Higashida, H. A. Rowley, R. G. Hart, G. F. Molinari, L. S. Frederick, H. C. Roberts, J. M. Gebel, C. A. Sila, G. A. Schulz, R. Roberts, and M. Gent, Stroke 57, 1603 (2001).
  12. H. H. Jae, K. H. Chang, I. C. Song, S. W. Park, Y. H. Kim, H. D. Kim, H. S. Kim, J. I. Choi, and M. H. Han, J. Korean Radiol. Soc. 43, 1 (2000). https://doi.org/10.3348/jkrs.2000.43.1.1
  13. J. H. Choi, J. J. Seo, J. K. Kim, T. W. Chung, Y. Y. Jeong, J. G. Park, H. K. Kang, and K. Kang, J. Korean Radiol. Soc. 49, 7 (2003). https://doi.org/10.3348/jkrs.2003.49.1.7
  14. Korea Food & Drug Administration, Korea Food & Drug Administration Notification No. 2009-164, Seoul (2009).
  15. International Commission on Radiological Protection, ICRP Publication, Oxford (1977).
  16. Y. Imanishi, A. Fukui, H. Niimi, D. Itoh, K. Nozaki, S. Nakaji, K. Ishizuka, H. Tabata, Y. Furuya, M. Uzura, H. Takahama, S. Hashizume, S. Arima, and Y. Nakajima, Eur. Radiol. 15, 41 (2005). https://doi.org/10.1007/s00330-004-2459-1