Abstract
In this study, ultimate strengths of 51 continuous reinforced concrete deep beams were evaluated by the ACI 318M-08's strut-tie model approach implemented with the presented indeterminate strut-tie model and load distribution ratio of the companion paper. The ultimate strengths of the continuous deep beams were also estimated by the shear equations derived based on experimental results, conventional design codes based on experimental and theoretical shear strength models, and current strut-tie model design codes. The validity of the presented strut-tie model and load distribution ratio was examined through the comparison of the strength analysis results classified according to the primary design variables of shear span-to-effective depth ratio, flexural reinforcement ratio, and concrete compressive strength. The present study results of ultimate strengths obtained using the indeterminate strut-tie model and load distribution ratio of the continuous deep beams agree fairly well with those obtained using other approaches. In addition, the present approach reflected the effect of the primary design variables on the ultimate strengths of the continuous deep beams consistently and accurately. Therefore, the present study will help structural designers to conduct rational and practical strut-tie model designs of continuous deep beams.
이 논문에서는 전편 논문에서 제안한 부정정 스트럿-타이 모델 및 하중분배율 결정식을 ACI 318M-08 스트럿-타이 모델 설계기준에 적용하여 파괴실험이 수행된 51개 연속지지 철근콘크리트 깊은 보의 극한강도를 평가하였다. 또한 연속 깊은 보의 극한강도를 실험식, 실험 및 이론 전단강도모델에 기초한 설계기준, 그리고 현 스트럿-타이 모델설계기준 등으로 평가하고, 그 결과를 이 연구의 방법에 의한 결과와 비교분석하여 이 연구에서 제안한 방법의 적합성을 검증하였다. 이 연구의 방법은 기존의 여러 방법에 비해 극한강도를 비교적 양호하게 평가하였으며, 또한 극한강도평가 시 연속 깊은 보의 강도 및 거동에 영향을 미치는 전단경간비, 콘크리트의 압축강도, 그리고 휨철근비 등 주요설계변수들의 영향을 기존 방법들에 비해 정확하고 일관성 있게 반영하였다. 따라서 이 연구의 방법은 부정정 스트럿-타이 모델 방법을 이용한 연속 깊은 보의 합리적이고 실용적인 설계를 가능하게 할 것으로 판단된다.