System identification is a fundamental step towards the application of structural health monitoring and damage detection techniques. On this respect, the development of evolved identification strategies is a priority for obtaining reliable and repeatable baseline modal parameters of an undamaged structure to be adopted as references for future structural health assessments. The paper presents the identification of the modal parameters of the Guangzhou New Television Tower, China, using a data-driven stochastic subspace identification (SSI-data) approach complemented with an appropriate automatic mode selection strategy which proved to be successful in previous literature studies. This well-known approach is based on a clustering technique which is adopted to discriminate structural modes from spurious noise ones. The method is applied to the acceleration measurements made available within the task I of the ANCRiSST benchmark problem, which cover 24 hours of continuous monitoring of the structural response under ambient excitation. These records are then subdivided into a convenient number of data sets and the variability of modal parameter estimates with ambient temperature and mean wind velocity are pointed out. Both 10 minutes and 1 hour long records are considered for this purpose. A comparison with finite element model predictions is finally carried out, using the structural matrices provided within the benchmark, in order to check that all the structural modes contained in the considered frequency interval are effectively identified via SSI-data.

Keywords

References

  1. Abe, M. Fujino, Y., Yanagihara, M. and Sato, M. (2000), "Monitoring of Hakucho suspension bridge by ambient vibration measurement", Proceedings of SPIE, 399, 237-244.
  2. Alicio lu, B. and Lus, H. (2008), "Ambient vibration analysis with subspace methods and automated mode selection: case studies", J. Struc. Engin-ASCE, 134(6), 1016-1029. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:6(1016)
  3. Carden, E.P. Brownjohn, J.M.W. (2008), "Fuzzy clustering of stability diagrams for vibration-based structural health monitoring", Comput-Aided Civ. Inf., 23(5), 360-372. https://doi.org/10.1111/j.1467-8667.2008.00543.x
  4. Carden, E.P. and Mita, A. (2009), "Challenges in developing confidence intervals on modal parameters estimated for large civil infrastructure with stochastic subspace identification", Struct. Health Monit., DOI:10.1002/stc.358.
  5. Casciati, F. and Ubertini, F. (2008), "Nonlinear vibration of shallow cables with semi-active tuned mass damper", Nonlinear Dynam., 53(1-2), 89-106. https://doi.org/10.1007/s11071-007-9298-y
  6. Casciati, F. and Fuggini, C. (2009a), "Towards global positioning system-based structural health monitoring", Trend. Civil Struct. Eng. Comp., (Eds. Topping, B.H.V., Costa Neves, L.F. and Barros, R.C), 15, 319-352.
  7. Casciati, F. and Fuggini, C. (2009b), "Engineering vibration monitoring by GPS: long duration records", Earthq. Eng. Eng. Vib., 8(3), 459-467. https://doi.org/10.1007/s11803-009-9058-8
  8. Chatzi, E.N. and Smyth, A.W. (2009), "The unscented Kalman filter and particle filter methods for nonlinear structural system identification with non-collocated heterogeneous sensing", Struct. Health Monit., 16(1), 99-123. https://doi.org/10.1002/stc.290
  9. Cluni, F., Gusella, V. and Ubertini, F. (2007), "A parametric investigation of wind-induced cable fatigue", Eng. Struct., 29(11), 3094-3105. https://doi.org/10.1016/j.engstruct.2007.02.010
  10. Conte, J.P., He, X., Moaveni, B., Masri, S.F., Caffrey, J.P., Wahbeh, M., Tasbihgoo, F., Whang, D.H. and Elgamal, A. (2008), "Dynamic testing of alfred zampa memorial bridge", J. Struct. Eng- ASCE, 134(6), 1006-1015. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:6(1006)
  11. Faravelli, L. and Ubertini, F. (2009), "Nonlinear state observation for cable dynamics", J. Vib. Control, 15(7), 1049-1077. https://doi.org/10.1177/1077546308094253
  12. Faravelli, L., Fuggini, C. and Ubertini, F. (2009a), "Towards a hybrid control solution for cable dynamics: theoretical prediction and experimental validation", Struct. Health Monit., 17(4), 386-403.
  13. Faravelli, L., Fuggini, C. and Ubertini, F. (2009b), "Experimental study on hybrid control of multimodal cable vibrations", Meccanica, DOI 10.1007/s11012-010-9364-2.
  14. Faravelli, L., Ubertini, F. and Fuggini, C. (2010), "System identification toward FEM updating of a super highrise building", Proceedings of the fifth European Workshop on Structural Health Monitoring, Sorrento, Italy, June - July.
  15. Frizzarin, M., Feng, M.Q., Franchetti, P., Soyoz, S., and Modena, C. (2008), "Damage detection based on damping analysis of ambient vibration data", Struct. Health Monit., 17(4), 368-385.
  16. Fuggini, C. (2009), "Using satellites systems for structural monitoring: accuracy, uncertainty and reliability", Ph.D. Dissertation, University of Pavia, Pavia, Italy.
  17. Gentile, C. and Gallino, N. (2008). "Ambient vibration testing and structural evaluation of an historic suspension footbridge", Adv. Eng. Softw., 39(4), 356-366. https://doi.org/10.1016/j.advengsoft.2007.01.001
  18. Hong, A.H., Betti, R. and Lin, C.C. (2009), "Identification of dynamic models of a building structure using multiple earthquake records", Struct. Health Monit., 16(2), 178-199. https://doi.org/10.1002/stc.289
  19. Hong, A.L., Ubertini, F. and Betti, R. (2011), "Wind analysis of a suspension bridge: identification and FEM simulation", J. Struct. Eng-ASCE, 137(1), 133-142. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000279
  20. Hua, X.G., Ni, Y.Q., Ko, J.M. and Wong, K.Y. (2007), "Modeling of temperature-frequency correlation using combined principal component analysis and support vector regression technique", J. Comput. Civil Eng., 21(2), 122-135. https://doi.org/10.1061/(ASCE)0887-3801(2007)21:2(122)
  21. Kang, S.G., Kwon, J.B., Lee, I.K. and Lee, G.H. (2008). "Structural behaviors of Seohae cable-stayed bridge affected by temperature", Proceedings of the 4th International Conference on Bridge Maintenance, Safety and Management, Seoul, Korea.
  22. Ko, J.M. and Ni, Y.Q. (2005). "Technology developments in structural health monitoring of large-scale bridges", Eng. Struct., 27(12), 1715-1725. https://doi.org/10.1016/j.engstruct.2005.02.021
  23. Li, H., Li, S., Ou, J. and Li, H. (2009), "Modal identification of bridges under varying environmental conditions: temperature and wind effects", Struct. Health Monit., DOI: 10.1002/stc.319.
  24. Macdonald, J.H.G. and Daniell, W.E. (2005). "Variation of modal parameters of a cable-stayed bridge identified from ambient vibration measurements and FE modelling", Eng. Struct., 27(13), 1916-1930. https://doi.org/10.1016/j.engstruct.2005.06.007
  25. Nayeri, R.D., Masri, S.M., Ghanem, R.G. and Nigbor, R.L. (2008), "A novel approach for the structural identification and monitoring of a full-scale 17-story building based on ambient vibration measurements", Smart Mater. Struct., 17(2), 1-19.
  26. Ni, Y.Q., Xia, Y., Liao, W.J. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou new TV tower", Struct. Health Monit., 16(1), 73-98. https://doi.org/10.1002/stc.303
  27. Ni, Y.Q., Zhou, H.F., and Ko, J.M. (2009), "Generalization capability of neural network models for temperaturefrequency correlation using monitoring data", J. Struc. Engin-ASCE, 135(10), 1290-1300. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000050
  28. Peeters, B. and De Roeck, G. (2000), "Reference based stochastic subspace identification in civil engineering", Inverse Probl., 8, 47-74. https://doi.org/10.1080/174159700088027718
  29. Peeters, B. and Ventura, C.E. (2003). "Comparative study on modal analysis techniques for bridge dynamic characteristics", Mech. Syst. Signal Pr., 17(5), 965-988. https://doi.org/10.1006/mssp.2002.1568
  30. Pridham, B.A. and Wilson, J.C. (2005), "A reassessment of dynamic characteristics of the Quincy Bay Bridge using output-only identification techniques", Earthq. Eng. Struct. D., 34, 787-805. https://doi.org/10.1002/eqe.455
  31. Ren, W.X., Peng, X.L. and Lin, Y.Q. (2005), "Experimental and analytical studies on dynamic characteristics of a large span cable-stayed bridge", Eng. Struct., 27(4), 535-548. https://doi.org/10.1016/j.engstruct.2004.11.013
  32. Reynders, E., Pintelon, R. and De Roeck, G. (2008), "Uncertainty bounds on modal parameters obtained from Stochastic Subspace Identification", Mech. Syst. Signal Pr., 22(4), 948-969. https://doi.org/10.1016/j.ymssp.2007.10.009
  33. Ubertini, F. (2008a), "Active feedback control for cable vibrations", Smart Struct. Syst. 4(4), 407-428. https://doi.org/10.12989/sss.2008.4.4.407
  34. Ubertini, F., Hong, A.H., Betti, R. and Materazzi, A.L. (2010), "Identification of wind-excited suspension bridges for SHM: a feasibility study", Proceedings of the 34th IABSE symposium, Venice, Italy, September.
  35. Ubertini, F. (2010), "Prevention of suspension bridge flutter using multiple tuned mass dampers", Wind Struct., 13(3), 235-256. https://doi.org/10.12989/was.2010.13.3.235
  36. Xia, Y., Ni, Y.Q., Ko, J.M. and Chen, H.B. (2008), "ANCRiSST benchmark problem on structural health Monitoring of high-rise slender structures", Proceedings of the 4th International Workshop on Advanced Smart Materials and Smart Structures Technologies, Tokyo, June.
  37. Van Overschee, P. and De Moor, B. (1996), "Subspace identification for linear systems: Theory-implementationapplications", Kluwer Academic Publishers, Dordrecht, The Netherlands.
  38. Weng, J.H., Loh, C.H. and Yang, J.N. (2009), "Experimental study of damage detection by data-driven subspace identification and finite-element mode updating", J. Struc. Engin-ASCE, 135(12), 1533-1544. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000079
  39. Wong, K.Y. (2004), "Instrumentation and health monitoring of cable-supported bridges", Struct. Health Monit., 11(2), 91-124. https://doi.org/10.1002/stc.33

Cited by

  1. Applications of structural health monitoring technology in Asia vol.16, pp.3, 2017, https://doi.org/10.1177/1475921716653278
  2. Evaluation of the dynamic characteristics of a super tall building using data from ambient vibration and shake table tests by a Bayesian approach 2017, https://doi.org/10.1002/stc.2121
  3. New insights into coherence analysis with a view towards extracting structural natural frequencies under operational conditions vol.77, 2016, https://doi.org/10.1016/j.measurement.2015.08.038
  4. Online correction of drift in structural identification using artificial white noise observations and an unscented Kalman Filter vol.16, pp.2, 2015, https://doi.org/10.12989/sss.2015.16.2.295
  5. Damage detection under varying temperature using artificial neural networks vol.24, pp.11, 2017, https://doi.org/10.1002/stc.1998
  6. Assessment of environmental and nondestructive earthquake effects on modal parameters of an office building based on long-term vibration measurements vol.26, pp.5, 2017, https://doi.org/10.1088/1361-665X/aa6ae6
  7. Mode identifiability of a cable-stayed bridge under different excitation conditions assessed with an improved algorithm based on stochastic subspace identification vol.17, pp.3, 2016, https://doi.org/10.12989/sss.2016.17.3.363
  8. Temperature effect on vibration properties of civil structures: a literature review and case studies vol.2, pp.1, 2012, https://doi.org/10.1007/s13349-011-0015-7
  9. Metamodeling of nonlinear structural systems with parametric uncertainty subject to stochastic dynamic excitation vol.8, pp.4, 2015, https://doi.org/10.12989/eas.2015.8.4.915
  10. Automated long-term dynamic monitoring using hierarchical clustering and adaptive modal tracking: validation and applications pp.2190-5479, 2018, https://doi.org/10.1007/s13349-018-0306-3
  11. Time-varying system identification using variational mode decomposition vol.25, pp.6, 2018, https://doi.org/10.1002/stc.2175
  12. Effect of Environmental Conditions on the Modal Response of a 10-Story Reinforced Concrete Tower vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/9476146
  13. Modal Parameters Identification Method Based on Symplectic Geometry Model Decomposition vol.2019, pp.None, 2011, https://doi.org/10.1155/2019/5018732
  14. Mono-Component Feature Extraction for Condition Assessment in Civil Structures Using Empirical Wavelet Transform vol.19, pp.19, 2011, https://doi.org/10.3390/s19194280
  15. A novel recursive stochastic subspace identification algorithm with its application in long-term structural health monitoring of office buildings vol.24, pp.4, 2011, https://doi.org/10.12989/sss.2019.24.4.459
  16. Ambient Effect Filtering Using NLPCA-SVR in High-Rise Buildings vol.20, pp.4, 2020, https://doi.org/10.3390/s20041143
  17. Analysis of Environmental and Typhoon Effects on Modal Frequencies of a Power Transmission Tower vol.20, pp.18, 2011, https://doi.org/10.3390/s20185169
  18. Wind engineering for high-rise buildings: A review vol.32, pp.3, 2011, https://doi.org/10.12989/was.2021.32.3.249
  19. Reducing the Training Samples for Damage Detection of Existing Buildings through Self-Space Approximation Techniques vol.21, pp.21, 2011, https://doi.org/10.3390/s21217155
  20. System Identification of a Volumetric Steel Modular Frame Using Experimental and Numerical Vibration Analysis vol.27, pp.4, 2011, https://doi.org/10.1061/(asce)ae.1943-5568.0000498
  21. Investigation of time-varying structural dynamic properties of high-rise buildings under typhoon conditions vol.46, pp.None, 2022, https://doi.org/10.1016/j.jobe.2021.103796