3-D Magnetic Field Simulation of Open-ended Cylinder Type Magnetic Shield

양쪽 끝이 열린 원통형 자기 실드캔의 3차원 자계 해석

  • Shin, Kwang-Ho (Department of Information & Communication Engineering, Kyungsung University)
  • 신광호 (경성대학교 정보통신공학과)
  • Received : 2011.04.04
  • Accepted : 2011.04.20
  • Published : 2011.06.30

Abstract

In this study, we have performed systematical FEM analysis for design of open-ended 3-layer magnetic shield. For the simulation to calculated shielding factors, the relative permeability was varied in the range of $2{\times}10^3\sim1{\times}10^5$, and the length of the magnetic cylinders and length difference between layers were changed. We found that the shielding factor of -60 dB were obtained with the relative permeability of over 20000 and the lengths of magnetic layers of 40 cm, 45 cm and 50 cm, and the uniform magnetic field could be obtained in the range of $10cm{\times}10cm-\phi$.

본 연구에서는 유한요소해석을 이용하여서 양쪽 끝이 열린 형상을 가진 원통형 3층 자기 실드를 설계하기 위한 해석을 수행하였다. 원통형 자성체의 투자율 범위 $2{\times}10^3\sim1{\times}10^5$에서 자기 차폐율을 검토하였고, 자성체의 길이 및 각 층간의 길이 차에 의한 자기 차폐율의 변화를 해석하였다. 투자율이 $2{\times}10^4$ 이상이고 각 층의 길이가 40 cm, 45 cm, 50 cm인 경우 -60 dB 이상의 자기 차폐율을 얻을 수 있었으며, 이때의 균일 자계 영역은 $10cm{\times}10cm-\phi$ 이상이었다.

Keywords

References

  1. A. J. Mager, IEEE Trans. Magn. 6, 67 (1970).
  2. 이용호, 권혁찬, 김진목, 임청무, 이상길, 박용기, 박종철, 한국자기학회지 6, 264 (1996).
  3. T. W. Kornack, S. J. Smullin, S.-K. Lee, and M. V. Romalis, Appl. Phys. Lett. 90, 223501 (2007). https://doi.org/10.1063/1.2737357
  4. S. K. Lee and M. V. Romalis, J. Appl. Phys. 103, 084904 (2008). https://doi.org/10.1063/1.2885711
  5. P. Sergeant, L. Dupre, and L. Vandernbossche, J. Appl. Phys. 97, 10E511 (2005). https://doi.org/10.1063/1.1850380
  6. http://www.comsol.com.
  7. http://www.magnetic-shield.com.

Cited by

  1. A Study on Shield Effect of Shield Case using SiFe Sheet vol.28, pp.2, 2014, https://doi.org/10.5207/JIEIE.2014.28.2.048