The expansion work that is wasted through the irreversible expansion through the PC valve of decompression process of the natural gas governor station can be recovered by replacing the process by an isentropic expansion. The energy and exergy analyses for the two decompression process models of power producing and current decompression process model are presented. Analysis results showed that the exergy by gas supply is 56.29%, the exergy by producing power is 32.12 % in case of preheating system and 22.52% in case of non-preheating system. The dead exergy at the PCV is generated much more network. As these results, the usefulness of exergy analysis is verified.

국내 천연가스 공급계통에 있어서 냉열 에너지의 동력 회수에 관한 엑서지 해석 방법을 개발하므로, 에너지 시스템의 유효이용 방안 모색과 함께 엑서지 해석의 효용성을 증명한다. 현재 운영 중인 (1) 가열기에 의한 가열-PVC 감압 공급 시스템, (2) 감압과정에 팽창기를 도입하는 가열-팽창일-PVC 감압 공급 시스템, (3) 가열기 없이 팽창기를 도입한 팽창기-PVC 감압의 경우에 대해 엑서지 해석을 수행한다. 시뮬레이션은 NG 공급 시스템에 팽창기를 도입을 모델링하고, 유입 NG의 압력과 온도, 출구 NG의 압력과 온도에 대해 이루어 졌다. 팽창기로부터 얻을 수 있는 전력생산량은 팽창기 입출구의 NG 압력비가 클수록 많아진다. 그러나 압력비가 커면 온도의 하강이 심해져, 팽창기 입구에서의 가스 가열이 필요하며 이에 따른 연료소비량도 압력비 증가와 함께 상승한다. 엑서지 해석은 시스템 내 에너지 손실 위치와 양을 알 수 있다. 해석결과 가열-PVC 감압의 공급 시스템에서 PCV에 의해 소멸되는 엑서지가 가장 높았으며, 이 소멸 엑서지는 팽창기 설치를 통해 동력을 회수하므로 줄일 수 있다. 팽창기 입구에서 NG의 온도 증가는 엑서지 회수율을 향상시킬 수 있지만, NG의 열손실로 인해 팽창기의 기계 엑서지 효율은 감소한다. 이들 결과로 부터 엑서지 해석의 효용성을 알 수 있다.