A Study on Self-Healing Bolted Joints using Shape Memory Alloy

형상기억합금을 이용한 자가치유 볼트접합부 시스템에 관한 연구

  • 장하주 (성균관대학교 u-City공학과) ;
  • 이창길 (성균관대학교 건설환경시스템공학과) ;
  • 박승희 (성균관대학교 사회환경시스템공학과)
  • Received : 2011.05.20
  • Accepted : 2011.10.05
  • Published : 2011.10.27

Abstract

This paper describes the smart structural system that uses smart materials for real-time monitoring and active control of bolted joints in steel structures. The impedance-based structural health monitoring (SHM) techniques, which utilize the electro-mechanical coupling property of piezoelectric materials, was used to detect loose bolts in bolted joints. By monitoring the measured electrical impedance and comparing it with the measured baseline, a bolt loosening damage was detected. The damage was evaluated quantitatively using the damage metrics in conductance signature with respect to the healthy states. When loosening damage was detected in the bolted joint, the external heater actuated the shape memory alloy (SMA) washer. Then the heated SMA washer expanded axially and adjusted the bolt tension to restore the lost torque. An experiment was conducted by integrating the piezoelectric-material-based SHM function and the SMA-based active control function on a bolted joint, after which the performance of thesmart self-healing joint system was investigated.

본 연구는 압전 센서를 이용한 구조물의 실시간 모니터링과 강구조물 볼트접합부의 동적 컨트롤이 가능한 자가치유 시스템에 관한 것이다. 볼트접합부의 볼트 풀림 손상 탐색을 위해서 압전 물질의 전기역학적 커플링 성질을 이용하는 임피던스 기반의 구조물건전성평가 기법을 이용하였다. 계측된 임피던스 값을 기준치 값과 비교함으로써 볼트 풀림 손상 진단이 가능하다. 볼트 풀림 손상은 손상지수를 이용하여 정량적으로 평가되어지고, 손상이 진단되면 형상기억합금 와셔에 감겨있는 외부히터가 와셔에 열을 가하게 된다. 열이 가해진 형상기억합금 와셔는 축방향으로 팽창하고, 볼트접합부는 볼트풀림으로 인해 잃어버린 토크력을 회복하게 된다. 압전 센서를 이용한 임피던스 기반의 구조물건전성 평가기법과 형상기억합금 기반의 볼트접합부 동적 컨트롤 기능과 이를 이용한 자가치유 볼트접합부 시스템의 적용가능성과 성능을 실험을 통해 평가하였다.

Keywords

References

  1. Bhalla, S., Naidu, A.S.K., and Soh, C.K., (2002) Influence of structure-actuator interactions and temperature on piezoelectric mechatronic signatures for NDE, Proc. SPIE-The International Society for Optical Engineering, Vol.5062, No.1, pp.263-269.
  2. Bhalla, S. and Soh, C.K. (2004) High frequency piezoelectric signatures for diagnosis of seismic/blast induced structural damages, NDT&E International, Vol.37, No.1, pp.23-33. https://doi.org/10.1016/j.ndteint.2003.07.001
  3. Chopra, I. (2002) Review ofstate ofart ofsmart structures and integrated systems, AIAA Journal, Vol.20, No.11, pp.2145-2187.
  4. Coles, S. (2001) An Introduction to Statistical Modeling of Extreme Values, Springer, Verlag. pp.47-49.
  5. Giurgiutiu, V., Zagrai, A., and Bao, J.J. (2002) Piezoelectric wafer embedded active sensors for aging aircraft structural health monitoring, International Journal of Structural Health Monitoring, Vol. 1, pp.41-61. https://doi.org/10.1177/147592170200100104
  6. Giurgiutiu, V., Zagrai, A., and Bao, J.J. (2004) Damage identification in aging aircraft structures with piezoelectric wafer active sensors, Journal of Intelligent Material Systems and Structures, Vol.15, No.9-10, pp.673-688. https://doi.org/10.1177/1045389X04038051
  7. Ihn, J.B. and Chang, F.K. (2004) Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: II. Validation using riveted joints and repair patches, Smart Materials and Structures, Vol. 13, No.3, pp.621-630. https://doi.org/10.1088/0964-1726/13/3/021
  8. Lee, S.J. and Sohn, H. (2006) Active self-sensing module for sensor diagnosis and structural health monitoring", Proceedings of 3rd European Workshop on Structural Health Monitoring, Granada, Spain.
  9. Lee, S.J. and Sohn, H. (2006) Active self-sensing scheme development for structural health monitoring, Smart Materials and Structures, Vol. 15, No.6, pp.1734-1746. https://doi.org/10.1088/0964-1726/15/6/028
  10. Liang, C., Sun, F.P., and Rogers, C.A. (1994) Coupled electro-mechanical analysis of adaptive material systems-determination of the actuator power consumption and system energy transfer, Journal of Intelligent Material Systems and Structures, Vol.5, No.1, pp.12-20. https://doi.org/10.1177/1045389X9400500102
  11. Lovell, P.A. and Pines, D.J. (1998) Damage Assessment in a Bolted Lap Joint, 5th Annual SPIE Smart Materials and Structures Symposium: Smart Buildings, Bridges and Highways, Vol.3325, pp.112-126.
  12. Muntges, D.E., Park, G., and Inman, D.J. (2001) Investigation of a Self-healing Bolted Joint Employing a Shape Memory. Actuator, Proceedings of SPIE, Vol.4327, pp.193-200.
  13. Niezrecki, C., Brei, D., Balakrishnan, S., and Moskalik, A. (2001) Piezoelectric actuation: State of the art, The Shock and Vibration Digest, Vol.33, No.4, pp.269-280. https://doi.org/10.1177/058310240103300401
  14. Park, G., Cudney, H., and Inman, D.J. (2000) Impedance-based health monitoring of civil structural components, American Society of Civil Engineers, Vol.6, No.4, pp.153-160.
  15. Park, G., Sohn, H., Farrar, C.R., and Inman, D.J. (2003) Overview of piezoelectric impedance-based health monitoring and path forward, The Shock and Vibration Digest, Vol.35, No.6, pp.451-463. https://doi.org/10.1177/05831024030356001
  16. Park, G., Muntges, D., and Inman, D.J. (2003) Self-repairing joints employing shape-memory alloy actuators, JOM, Vol.55, No.12, pp.33-37. https://doi.org/10.1007/s11837-003-0007-0
  17. Park, G., Farrar, C.R., Rutherford, A.C., and Robertson, A.N. (2006) Piezoelectric active sensor self-diagnostics using electrical admittance measurements, Journal of Vibration and Acoustics, Vol.128, No.4, pp.469-476. https://doi.org/10.1115/1.2202157
  18. Park, S.,Yun, C.B., Roh,Y.,and Lee, J.J. (2006) PZT-based active damage detection techniques for steel bridge components, Smart Materials and Structures, Vol.15, No.4, pp.957-966. https://doi.org/10.1088/0964-1726/15/4/009
  19. Park, S., Grisso, B.L., Inman, D.J., and Yun, C.-B. (2007) MFC-based structural health monitoring using a miniaturized impedance measuring chip for corrosion detection, Reserch in Nondestructive Evaluation, Vol.18, No.2, pp.139-150. https://doi.org/10.1080/09349840701279937
  20. Peairs, D.M., Park, G., and Inman, D.J. (2002) Low Cost Impedance Monitoring Using Smart Materials, Proceeding of the First European Workshop on Structural Health Monitoring, Ecole Normale Superieure, Paris, France, July 10-12.
  21. Rogers, C.A., Liang, C., and Fuller, C.R. (1991) Active Damage Control of Hybrid Material Systems Using Induced Strain Actuators, Proc. AIAA 32nd Structure, Structural Dynamics, and Materials Conference, Paper No. AIAA 91-1145-CP.