Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles

베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석

  • 신화영 (경희대학교 대학원) ;
  • 김곤 (강원대학교 건축학부) ;
  • 김정태 (경희대학교 건축공학과)
  • Received : 2010.12.30
  • Accepted : 2011.04.15
  • Published : 2011.04.30

Abstract

Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Keywords

References

  1. 김유신, 박병철, 정근영, 최안섭, 이정호, "롤러 쉐이드와 베니션 블라인드의 높이에 따른 주광분포 비교", 대한건축학회 학술발표대회논문집, 제 27권 제1호, 2007, pp.1001-1004.
  2. 박병철, 김유신, 정근영, 최안섭, 이정호, "RADIANCE 소프트웨어를 이용한 롤러 쉐이드와 베니션 블라인드에 의한 실내 주광분포 분석 및 창면 글레어(DGI) 평가", 대한건축학회 학술발표대회논문집, 제 27권 제1호, 2007, pp.993-996.
  3. 백주영, 김지현, 여명석, 김광우, "오피스 건물의 재실자 블라인드 사용실태 분석", 대한건축학회 논문집, 제22권 제12호, 2006, pp.311-318.
  4. M. Foster, T. Oreszczyn, "Occupant control of passive systems: the use of Venetian blinds", Building and Environment 36 (2001) pp. 149-155 https://doi.org/10.1016/S0360-1323(99)00074-8
  5. T. E. Kuhn. "Solar control: A general evaluation method for facades with venetian blinds or other solar control systems", Energy and Buildings 38 (2006) pp.648-660. https://doi.org/10.1016/j.enbuild.2005.10.002
  6. V. Inkarojrit Monitoring and modelling of manually-controlled Venetian blinds in private offices: a pilot study Journal of Building Performance Simulation,Volume 1, Issue 2 June 2008, pp. 75-89. https://doi.org/10.1080/19401490802021012