DOI QR코드

DOI QR Code

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (2)- Evaluation of Application Rebar with Electro-Deposition Using Sea Water

해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (2) -해수전착된 구조용 철근의 적용성 평가

  • 권성준 (한남대학교 건설시스템공학과) ;
  • 이상민 (비앤티엔지니어링(주)) ;
  • 박상순 (상명대학교 건설시스템공학과)
  • Received : 2012.04.05
  • Accepted : 2012.08.02
  • Published : 2012.11.30

Abstract

When RC (Reinforced Concrete) structures are exposed to sea water, steel corrosion can occur and this leads a degradation of structural performance. Referring the electro-deposition system with sea water from the 1st step research, durability and structural performance are evaluated in coated steel and RC members containing it in the 2nd research. In the durability performance test, Half Cell Potential test is performed and the coated steel is evaluated to have the high resistance to corrosion, which shows only 35% of corrosion velocity in normal (bare) steel. In the structural performance test, tensile strength, adhesive strength, and flexural/shear in RC member are performed. For the electro-deposit coated steel, increasing ratios of 3.2% and 8.8% are evaluated in the test of tensile strength and adhesive strength, respectively. For the structural test in RC member, there is no big difference between RC members with coated and non-coated steel in ultimate load and failure pattern It is evaluated that the chemical compound with $CaCO_3$ and $Mg(OH)_2$ from electro-deposition causes slightly increased structural performance. The electro-deposit coated steel can be more widely applied after performance verification from several tests like fatigue, resistance to impact, and long term-submerging test.

해수에 노출된 콘크리트 구조물은 시간의 경과에 따라 철근부식이 야기될 수 있으며, 이는 구조적인 성능저하로 진전된다. 1단계 연구에서 도출된 해수전착시스템의 개발을 통하여 2단계 연구에서는 해수전착 코팅된 철근 및 코팅철근을 사용한 RC 콘크리트 부재의 구조적, 내구적 성능이 평가되었다. 내구적 성능평가에서는 반전위 측정이 수행되었는데, 코팅된 철근은 일반철근의 35%수준의 부식속도를 가지고 있었으므로 높은 내부식성을 확보하고 있었다. 구조실험에서는 직접인장시험, 부착력시험, RC 부재를 이용한 휨 및 전단시험이 수행되었다. 인장강도 시험에서는 3.2%, 부착성능에서는 8.8%의 강도 증가가 코팅된 철근에서 평가되었다. RC보에 대한 실험에서는 최대하중 및 파괴형태는 두가지 경우에서 거의 동일하게 평가되었다. 해수전착된 시편은 철근주위에 콘크리트와 비슷한 화합물(수산화마그네슘, 탄산칼슘)이 형성되므로 부착력 및 강도를 일부 증가시키는 것으로 평가되었다. 해수전착철근은 피로, 내충격성, 장기침지실험 등을 통하여 성능이 입증되면 더욱 활발하게 사용될 것으로 사료된다.

Keywords

References

  1. American Society for Testing and Materials, Standard Test, Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete: C 876-91, Book of ASTM Standards, Section 4, Philadelphia, PA, USA, 1999, pp.1-6.
  2. B&T Engineering, Practical Development of Anti-Corrosive Steel Bar Material for Reinforced Concrete Prepared by Hot-Dip Galvanizing and S.W-Electrodeposition Methods, 06 Construction Core D08, Technical Report, 2010, pp.88-144.
  3. Broomfield JP. Corrosion of steel in concrete : understanding, investigation and repair, London, E&FN, 1997, pp.2-18.
  4. Emmons, P. H., Concrete Repair and Maintenance Illustrated, R. S. MEANS COMPANY, 1994, pp.36-42.
  5. Hassonand, D. F., Corwe, C. R. Materials for Marine System and Structures, vol. 28, Academic press, 1998, pp.46-49.
  6. Irethewey, K. R., Chamberiain, J., Corrosion for Science and Engineering, Longman Scientific & Technical, 1995, pp.375-388.
  7. Kim, J.-S., Shin, Y.-S., Lee, S., Kim, K.-S., "The Effect of Chloride on the Corrosion of Reinforced Concrete", Journal of Korea Institute for Structural Maintenance Inspection, vol. 9, No. 2, 2005, pp.147-154.
  8. Korean Standards, Steel bars for concrete reinforcement, KS D 3504, 2011, pp.1-9.
  9. Korean Standards, Tensile testing machines, KD B 5521, 2007, pp.1-5.
  10. Kwon, S.-J., Lee, M.-H., Park, S.-S., "Development and Application of Anti-Corrosive Steel Using Electro- Deposition of Sea Water (1)-Development of Electro- Deposition System Using Sea Water", Journal of Korea Institute for Structural Maintenance Inspection, vol. 16, No. 5, 2012, pp.78-87.
  11. Kwon, S.-J., Na, U. J., Park, S.-S., Jung, S. H., "Service Life Prediction of Concrete Wharves with Early-Aged Crack : Probabilistic Approach for Chloride Diffusion", Structural Safety, vol. 31, No. 1, 2010, pp.75-83.
  12. Lee, C.-S., Bae, I.-Y., Kim, K.-J., Moon, K.-M., Lee, M.-H., "Properties Analysis of Environment Friendly Electrodeposit Films Formed at Various Current Density Conditions in Natural Seawater", Journal of Korea Institute of Surface Engineering, vol. 37, No. 5, 2004, pp.253-262.
  13. Lee, C. S., Kim, Y. J., Kim, K. J., Lee, M. H., "Calcareous Deposit Films Prepared in Seawater and their Properties Analysis", Proceedings of the Korean Institute of Surface Engineering, Spring Annual Conference, 2003, p.30.
  14. Lee, M. H. Ryu, H. J., "Surface Coating Method of Environment-Friendly Calcareous Deposit formed in Natural Seawater", Fourth International Symposium on Biomimetic Materials Processing, vol. 4, 2004, p.94.
  15. Moller, H., "The Influence of Mg+ on the Formation of Calcareous Deposit on a Freely Corroding Low Carbon Steel in Sea Water", Corrosion Science, vol. 49, 2007, pp.1992-2001. https://doi.org/10.1016/j.corsci.2006.10.011
  16. Ou, K. C., Wu, J. K., "Effect of Calcareous Deposits Formation on the Hydrogen Absorption of Steel", Materials Chemistry and Physics, vol. 48, No. 1, 1997, pp.52-55. https://doi.org/10.1016/S0254-0584(97)80076-4
  17. Ryu, H. J., Lee, M. H., "Electro-deposit formed by Mesh-Electrodeposition Technology on Steel Plate in Seawater and Their Corrosion Resistance", Journal of the Corrosion Science Society of Korea, vol. 29, No. 4, 2000, pp.240-250.
  18. Yang, E. I., Jin, S. H., Kim, M. Y., Choi, Y. S., Han, S. H., "Effect of Initial Flextural Crack on Resistance to Chloride Penetration into Reinforced Concrete Members", Journal of Korea Institute for Structural Maintenance Inspection, vol. 15, No. 2, 2011, pp.79-87.

Cited by

  1. 칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링 vol.23, pp.7, 2012, https://doi.org/10.11112/jksmi.2019.23.7.1