DOI QR코드

DOI QR Code

Seismic Performance Evaluation of Complex-Shaped Tall Buildings by Lateral Resisting Systems

횡력저항시스템에 따른 비정형 초고층건물 내진성능평가

  • 윤우석 ((주)창민우구조컨설탄트 부설건설기술연구소) ;
  • 이동훈 ((주)창민우구조컨설탄트 부설건설기술연구소) ;
  • 조창희 ((주)창민우구조컨설탄트 부설건설기술연구소) ;
  • 김은성 ((주)창민우구조컨설탄트 부설건설기술연구소) ;
  • 이동철 ((주)창민우구조컨설탄트 부설건설기술연구소) ;
  • 김종호 ((주)창민우구조컨설탄트)
  • Received : 2012.11.09
  • Accepted : 2012.11.28
  • Published : 2012.12.31

Abstract

The objective of this research is to examine how the lateral resisting system of selected prototypes are affected by seismic zone effect and shape irregularity on its seismic performance. The lateral resisting systems are divided into the three types, diagrid, braced tube, and outrigger system. The prototype models were assumed to be located in LA, a high-seismicity region, and in Boston, a low-seismicity region. The shape irregularity was classified with rotated angle of plane, $0^{\circ}$, $1^{\circ}$, $2^{\circ}$. This study performed two parts of analyses, Linear Response and Non-Linear Response History(NLRH) analysis. The Linear Response analysis was used to check the displacement at the top and natural period of models. NLRH analysis was conducted to invest base shear and story drift ratio of buildings. As results, the displacement of roof and natural period of three structural systems increase as the building stiffness reduces due to the changes in rotation angle of the plane. Also, the base shear is diminished by the same reason. The result of NLRH, the story drift ratio, that was subject to Maximum Considered Earthquake(MCE) satisfied 0.045, a recommended limit according to Tall Building Initiative(TBI).

본 연구는 횡력저항시스템별로 프로토타입 모델을 선정하고 지진지역과 비정형성에 따른 내진성능 영향력을 검토하였다. 프로토타입 모델은 다이아그리드 시스템과 브레이스튜브 시스템 그리고 아웃리거 시스템을 선정하였다. 또한 각 횡력저항시스템별 평면 비틀림 각도를 $0^{\circ}$, $1^{\circ}$($1.5^{\circ}$), $2^{\circ}$($3^{\circ}$) 씩 변화하여 내진성능을 검토하였다. 지진지역은 강진지역(LA), 약진지역(Boston)을 선정하였다. 선형응답해석은 프로토타입 모델의 풍변위, 고유주기를 검토하였다. Non-Linear Response History(NLRH) 해석에서는 밑면전단력, 층간변위비를 검토하였다. 검토결과 다이아그리드 시스템과 브레이스튜브 시스템 그리고 아웃리거 시스템 모두 평면 비틀림 각도가 증가할수록 건물 전체의 강성이 줄어들었다. 또한 평면 비틀림 각도가 증가할수록 풍변위와 고유주기 결과가 증가하고 건물 전체의 강성이 줄어들어 밑면전단력이 감소하였다. 끝으로, NLRH 해석 결과 강진과 약진지역 모두 Tall Building Initiative(TBI)의 Maximum Considered Earthquake(MCE)수준의 층간변위비 제한값 0.045를 만족하여 허용범위내의 내진성능을 만족하고 있는 것으로 나타났다.

Keywords

References

  1. AISC (2005) ANSI/AISC 360-05 Specific for Structural Steel Buildings, American Institute of Steel Construction.
  2. ASCE (2006) ASCE/SEI 7-05 Minimum Design Loads for Building and Other Structures, American Society of Civil Engineers.
  3. Carroll, C. (2008) Case Study : CCTV Building- Headquarters & Cultural Center, CTBUH Journal, 3, pp.14-24.
  4. Computers & Structures Inc. (2005) ETABS Integrated Building Design Software User's Guide.
  5. Computers & Structures Inc. (2006) Perform 3D Nonlinear Analysis and Performance Assessment for 3D Structures User Guide Version 4.
  6. Computers & Structures Inc. (2006) Perform Components and Elements for Perform-3D and Perform-Collapse Version 4.
  7. Kim, S.W. (2011) Seismic Performance Evaluation of Highrise Steel Diagrid Frames, Journal of the Computational Structural Engineering, 24(3), pp. 307-318.
  8. Moon, K.S. (2009) Design and Construction of Steel Diagrid Structures, Nordic Steel Construction Conference.
  9. Moon, K.S. (2010) Stiffness-based Design Methodology for Steel Braced Tube Structures : a Sustainable Approach, Engineering Structures, 32, pp.3163-3170. https://doi.org/10.1016/j.engstruct.2010.06.004
  10. Moon, K.S., Connor, J.J., Fernandez, J.E. (2007) Diagrid Structural Systems for Tall Buildings : Characteristics and Methodology for Preliminary Design, The Structural Desing of Tall and Special Buildings, 16, pp.205-230. https://doi.org/10.1002/tal.311
  11. PEER (2010) Tall Buildings Initiative Guidelines for Performance-Based Seismic Design of Tall Buildings Version 1.0.
  12. PEER (2011) Users Manual for the PEER Ground Motion Database Web Application.
  13. Yun, W.S., Lee, D.H., Lee, D.C., Kang, D.E. (2012) Seismic Performance Assesment of Complex-shaped Tall Building Prototype Models, The Computational Structural Engineering Institute of Korea Annual Conference.