DOI QR코드

DOI QR Code

The selection of basic platform for improving the sensitivity of neutravidin rapid detection kit

뉴트라비딘 검출용 간이 진단키트의 성능향상을 위한 기본 플랫폼 선정

  • Choi, Sunmi (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration) ;
  • Kim, Giyoung (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration) ;
  • Om, Aeson (Food Safety & Toxicology Lab., Dept. of Food & Nutrition, Hanyang University) ;
  • Moon, Jihea (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration) ;
  • Park, Saetbyeol (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration) ;
  • Lee, Sangdae (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration) ;
  • Kim, Hyuk Joo (Biosensor Lab., Dept. of Agricultural Engineering, National Academy of Agricultural Science, Rural Development Administration)
  • 최선미 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실) ;
  • 김기영 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실) ;
  • 엄애선 (한양대학교 식품영양학과 식품 안전 및 독성연구실) ;
  • 문지혜 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실) ;
  • 박샛별 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실) ;
  • 이상대 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실) ;
  • 김혁주 (농촌진흥청 국립농업과학원 농업공학부 바이오센서연구실)
  • Received : 2012.09.02
  • Accepted : 2012.11.14
  • Published : 2012.12.31

Abstract

This study was performed to optimize the basic platform of a lateral flow immunoassay. Improvement of the limit of detection (LOD) was evaluated according to the width of a nitrocellulose membrane with varying concentrations of analyte. The analyte, neutravidin was detected based on the avidin-biotin interaction. The antibody-Au nanoparticle conjugation was mostly stabled in a PBS buffer of pH 7.3. The optimal widths of a nitrocellulose membrane were 4 and 6 mm considering the sample flow rate and signal strength of the test line on the membrane. The LOD of neutravidin was 0.001 mg/ml in the optimum conditions.

Keywords

References

  1. Babacan S, Pivarnik P, Letcher S, Rand A. 2002. Piezoelectric flow injection analysis biosensor for the detection of Salmonella typhimuium. Journal of Food Science 67(1):314-320. https://doi.org/10.1111/j.1365-2621.2002.tb11403.x
  2. Bazin I, Nabais E, Lopez-Ferber M. 2010. Rapid visual tests: Fast and reliable detection of ochratoxin A. Toxins 2(9): 2230-2241. https://doi.org/10.3390/toxins2092230
  3. Choi JH, Lee SJ, Jang SC, Kim KC. 2011. Development of disposable enzyme-linked immunosensor strip platform. 20(6): 400-405. [in Korean] https://doi.org/10.5369/JSST.2011.20.6.400
  4. Hossain ZSM. Luckham MRE, McFadden MJ, Brennan JD. 2009. Reagentless bidirectional lateral flow bioactive paper sensors for detection of pesticides in beverage and food samples. Analytical Chemistry 81(21):9055-9064. https://doi.org/10.1021/ac901714h
  5. Kang BK, Oh JS, Lee CS, Park BK, Park YN, Hong KS, Lee KG, Cho BK, Song DS. 2010. Evaluation of a rapid immunodiagnostic test kit for rabies virus. Journal of Virological Methods 145(1): 30-36.
  6. Kim GY, Moon JH, Om AS, Yang GM, Mo CY, Kang SW, Cho HK. 2009. Evaluation of antibody immobilization methods for detection of Salmonella using impedimetric biosensor. Journal of Biosystems Engineering 34(4):254-259. [in Korean] https://doi.org/10.5307/JBE.2009.34.4.254
  7. Kim GY, Yang GM, Park SB, Kim YH, Lee KJ, Son JY, Kim HJ, Lee SR. 2011. Rapid detection kit for Salmonella typhimurium. Journal of Biosystems Engineering 36(2):140-146. [in Korean] https://doi.org/10.5307/JBE.2011.36.2.140
  8. Kim YK. 2007. Signal transducing methods for immunesensing devices. BioChip Journal. 1:145-150. [in Korean]
  9. Mehlotra RK, Lorry K, Kastens W, Miller SM, Alpers MP, Bockarie M, Kazura JW, Zimmerman PA. 2000. Random distribution of mixed species malaria infections in Papua New Guinea. The American Journal of Tropical Medicine and Hygiene 62(2):225-231.
  10. Oh JS, Ha GW, Cho YS, Kim MJ, An DJ, Hwang KK, Lim YK, Park BK, Kang BK, Song DS. 2006. One-step immunochromatography assay kit for detecting antibodies to canine parvovirus. Clinical and Vaccine Immunology 13(4):520-524. https://doi.org/10.1128/CVI.13.4.520-524.2006
  11. Park SJ, Kim YK. 2011. Enzyme-linked immunosorbent assay strip sensor for rapid detection of Staphylococcus aureus. Journal of Industrial and Engineering Chemistry 22(5):522-525. [in Korea]
  12. Sithigorngul W, Rukpratanporn S, Sittidilokratna N, Pecharaburanin N, Longyant S, Chaivisuthangkura P, Sithigorngul P. 2007. A convenient immunochromatographic test strip for rapid diagnosis of yellow head virus infection in shrimp. Journal of Virological Methods 140(1-2):193-199. https://doi.org/10.1016/j.jviromet.2006.11.034
  13. Tang Y, Zhai YF, Xiang JJ, Wang H, Liu B, Guo CW. 2010. Colloidal gold probe-based immunochromatographic assay for the rapid detection of lead ions in water samples. Environmental Pollution 158(6):2074-2077. https://doi.org/10.1016/j.envpol.2010.03.001