A Application Method of Engine-Generator Power System in Ambulance

긴급 구난차량의 발전시스템에 관한 연구

  • 정원석 (강원대학교 방재전문대학원(방재설비전공)) ;
  • 이봉석 (강원대학교 제어계측공학과) ;
  • 심한섭 (경남과학기술대학교 자동차공학과)
  • Published : 2012.06.30

Abstract

Recently, the electric device has been launching owing to the development of industry. That development also can maximize the efficiency of generator. The emergency rescue vehicle operation differs from ordinary vehicles in engine life and usage distances. For the application of this system, this research proposes the ways to operate the emergency rescue vehicle operations more efficiently. Currently, many power systems, especially motors, developed with a large output of power. It is possible to produce electricity in the engine room with enough space and to operate all equipment within the rating load capacity.

Keywords

References

  1. Jae-kwang Kim, Dong-Hyeok Cho, Hyun-Kyo Jung, Cheol-Gyun Lee), "Characteristic Analysis of Disk Type Generator with Separated Slots, Spring Conference", pp. 150-152, 2001.
  2. Jae-Seok Oh, Ju-Hwan Oh, Byung-Il Kwon, "Characteristics Analysis According to Switching of Switched Reluctance Generator, Transactions of The Korean Institute of Electrical and Engineers". Vol. 57, No. 8, pp. 1356-1361, 2008.
  3. D. H. Lee, "Inverter Power Control System = Control device of inverter source", Korea Science and Technology. 1992.
  4. K. W. Lee, Method and Apparatus of Simulate Capability Test in Inverter, Korea Patent No. 1005116480000. 2005.
  5. J. M. Jho, N. Y. Harm, D. G. Kim, S. J. Lee, S. N. Kim, H. G. Lee, K. H. Han, "A Study on the Inverter performance test by Simulated Converter, Power Electronics Annual Conference", pp. 765-768, The Korean Institute of Power Electronics, 2003.