DOI QR코드

DOI QR Code

Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under Low Temperature -

냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 저온 가혹조건에서의 가속계수와 단축 시험기간 -

  • Jung, Y.M. (Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University) ;
  • Joo, W.J. (Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University) ;
  • Jeong, S.K. (Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University)
  • Received : 2011.12.15
  • Accepted : 2012.01.30
  • Published : 2012.04.30

Abstract

Generally accelerated life test is well known as one method to reduce reliability qualification test period. This test is conducted under the higher stress condition than normal condition. So it can save the test time by calculating the acceleration factor from the relationship between the worst stress condition and normal condition. This paper investigates the worst stress condition for the accelerated life test to increase the acceleration factor. Especially, we focused on the method to obtain effective acceleration factors under the worst stress condition. Moreover, we considered how to decide the worst stress condition by looking for the operating limit of this system. The acceleration factor can be estimated from the ratio of the kinematic viscosity in the normal condition and the worst stress condition, the lowest temperature, by using Arrhenius relationship. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Keywords

References

  1. J. H. Kim and W. Jeong, 2008, "Reliability Engineering", Cheongmungak, pp. 178-211.
  2. C. W. Lee and J. H. Lim, 2004, "New Reliability Engineering", Boseonggak, pp. 253-260.
  3. J. U. Baek, 2007, "Accelerated Life Test", Episteme, pp. 78-168.
  4. D. S. Ryu et al., 2005, "Accelerated Life Test on the Failure Mode of Helix Ice Dispenser in Side by Side Refrigerator", The Korean Society for Power System Engineering, pp. 144-149.
  5. T. G. Lee et al., 2005, "Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by the Accelerated Life Test", The Society of Air-Conditioning and Refrigerating Engineering of Korea, Vol. 17, No. 12, pp. 1169-1176.
  6. S. Wei et al., 2007, "Development of Accelerated Life Test Method for TCU Life Analysis", The Society of Automative Engineers, Vol. 7, pp. 2195-2200.
  7. S. W. Woo and J. K. Lee, 2008, "Reliability Design of the Hinge Kit System in Common Refrigerator under Repetitive Load", Korean Institute of Industrial Educators, Vol. 33, No. 2, pp. 312-324.
  8. J. Y. Byun et al., 2008, "Establishment of the Acceleration Factor to Reduce the Period of Reliability Life Test of a Compressor in a Refrigeration System", The Korean Society for Power System Engineering(fall), pp. 233-238.
  9. J. Y. Byun et al., 2009, "Influence of Variables Related to Accelerated Life Test Time for a Compressor in a Refrigerator", The Korean Society for Power System Engineering(spring), pp. 343-347.
  10. W. Nelson, 2004, "Accelerated Testing : Statistical Models, Test Plans, and Data Analyses", John Wiley & Sons, Inc.

Cited by

  1. A study on the safety electric grass cutter system using the planetary reduction gear device vol.14, pp.12, 2013, https://doi.org/10.1007/s12541-013-0290-9