DOI QR코드

DOI QR Code

Development of Mobile u-Healthcare System in WSN

무선센서네트워크 환경의 모바일 u-헬스케어 시스템 개발

  • 이승철 (부경대학교 전자정보통신연구소) ;
  • 정완영 (부경대학교 전자공학과)
  • Received : 2012.04.09
  • Accepted : 2012.04.16
  • Published : 2012.04.30

Abstract

Wireless sensor network (WSN) technology provides a variety of medical and healthcare solutions to assist detection and communication of body conditions. However, data reliability inside WSN might be influenced to healthcare routing protocol due to limited hardware resources of computer, storage, and communication bandwidth. For this reason, we have conducted various wireless communication experiments between nodes using parameters such as RF strength, battery status, and deployment status to get a optimal performance of mobile healthcare routing protocol. This experiment may also extend the life time of the nodes. Performance analysis is done to obtain some important parameters in terms of distance and reception rate between the nodes. Our experiment results show optimal distance between nodes according to battery status and RF strength, or deployment status and RF strength. The packet reception rate according to deployment status and RF strength of nodes was also checked. Based on this performance evaluation, the optimized sensor node battery and deployment in the developed our mobile healthcare routing protocol were proposed.

무선센서네트워크 기술은 환자의 생체신호를 측정하고 전송할 수 있도록 도와 다양한 메디컬과 헬스케어 솔루션을 제공한다. 그러나 무선센서네트워크 기반의 데이터 신뢰성은 센서노드의 하드웨어 리소스 제약으로 인해서 헬스케어 라우팅 프로토콜에 상당한 영향 미칠 수 있다. 이러한 이유 때문에 본 연구에서는 무선센서네트워크 환경에서 헬스케어 시스템에 적용 가능한 모바일 헬스케어 라우팅 프로토콜에 성능향상을 시킬 목적으로 RF 세기, 배터리 상태, 배치 상태 등의 조건을 이용하여 다양한 통신실험을 수행하였다. 이 실험은 노드 간 거리와 수신율의 관점에서 몇몇 중요한 파라멘트를 획득하기 위해서 수행하였다. 배터리 상태와 RF 세기와의 관계, 노드 배치 상태와 RF 세기와의 관계 등에 따라 최적 통신 거리를 평가하고, 또한 노드 간 배치 상태와 RF 세기 따른 패킷 수신율 평가하였다. 이 실험결과를 바탕으로 본 연구에서 개발한 모바일 헬스케어 라우팅 프로토콜의 최적 노드 전력제어 및 배치 방법을 제안하였다.

Keywords

References

  1. Y. B. Kim, S. K. Yoo, D. Y. Kim, "Ubiquitous Healthcare: Technology and Service", Studies in Computational Intelligence, Vol 19, 2006.
  2. R. G. Lee, C. C. Hsiao , C. C. Chen, M. H. Liu, "A mobile-care system integrated with Bluetooth blood pressure and pulse monitor, and cellular phone", IEICE Trans Inform Syst 2006, Vol. E89-D, Issue 5, pp. 1702-1711, 2006. https://doi.org/10.1093/ietisy/e89-d.5.1702
  3. U. Varshney, "Patient monitoring using infrastructure-oriented wireless LANs", Int. J. Electron Healthcare, Vol.2, No. 2, pp. 149-163, 2006.
  4. F. Hu, M. Jiang, L. Celentano, Y. Xiao, "Robust medical ad hoc sensor networks (MASN) with wavelet-based ECG data mining", Ad Hoc Networks, Vol. 6, Issue 7, pp. 986-1012, 2008. https://doi.org/10.1016/j.adhoc.2007.09.002
  5. B. Zhou, C. Hu, H. Wang, and R. Guo, "A wireless sensor network for pervasive medical supervision", International Conference on Integration Technology, pp. 740-744, 2007.
  6. I. F. Akyildiz, S. Weilian, Y. Sankarasubramaniam, and E. Cayirci, "A Survey on Sensor Networks", Comm. IEEE., Vol. 40, No. 8, pp.102-114, 2002.
  7. F. Ye, A. Chen, S. Lu, L. Zhang, "A scalable solution to minimum cost forwarding in large sensor networks", in Proceedings of IEEE 10th Int. Conf. Computer Communications and Networks, Scottsdale, Arizona, pp. 304- 309, 2001.
  8. D. Yupho and J. Kabara, "Continuous vs. Event Driven Routing Protocols for WSNs in Healthcare Environments", In Pervasive Health Conference and Workshops, pp. 1-4, 2006.
  9. Seung-Chul Lee and Wan-Young Chung, "Design and Implementation of Minimum Cost Forwarding Model in Sensor Network Database for Healthcare Application", Sensor Letters, Vol. 9, number 1, February 2011, pp. 433-438. https://doi.org/10.1166/sl.2011.1494

Cited by

  1. The effect of Smart Care ubiquitous health service on hypertension management vol.14, pp.3, 2013, https://doi.org/10.5762/KAIS.2013.14.3.1213