Abstract

Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide ($CO_2$) were measured. Results: The TSB concentrations ($GM{\pm}GSD$) were $452({\pm}1.3)cfu/m^3$ in open-plan offices, $366({\pm}1.3)cfu/m^3$ in cellular offices and $287({\pm}1.5)cfu/m^3$ in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations ($GM{\pm}GSD$) of fungi were found in the indoor air of cellular offices $128({\pm}1.0)cfu/m^3$, which was at least three times higher than the concentrations in mixed offices $43({\pm}1.0)cfu/m^3$ (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants.

Keywords

References

  1. National Academy of Sciences (NAS), Human exposure assessment for airborne pollutants. Washington DC; 1993.
  2. Robinson J, Nelson WC. National human activity pattern survey data base. US EPA, Reaseach triangle park, NC; 1995.
  3. World Health Organization (WHO). Air quality guidelines for Europe, 2nd ed. Copenhagen, World Health Organization Regional Office for Europe. WHO Regional Publications, European Series, No. 91; 2000.
  4. Woods JE, Cone JE, Hodgson MJ. Problem buinding; building associated illness and sick building syndrome. Med State Art Rev, 1989; 4: 753-770.
  5. Occupational Safety and Health Administration (OSHA). Indoor Air Quality. 2001; 59: 15968-16039.
  6. Roh YM, Lee CM, Kim SW, Kim CN, Kim HW, Cho KH, Choi HC, Kang JH, Kim JM. A study on the characteristics of indoor air quality in office and subjective symptoms of office workers. J Korean Soc Occup Environ Hyg. 2004; 14(3): 270-282.
  7. Lee CM, Kim YS, Kim KY, Kim JC, Jeon HJ. Trend of study on suspended microorganism in Korea. Korean Society for Indoor Environment. 2007; 4(1): 59-71.
  8. Miller SYS, Cheng JM. Macher guest editorial. Aerosol Sci. Technol. 1999; 30: 93-99. https://doi.org/10.1080/027868299304697
  9. Bernstein RS, Sorenson D. Garabrant C. Reaux Treitman RD, Exposures to respirable, airborne penicillium from contaminated ventilation system, clinical, environmental and epidemiological aspects, Am Ind Hyg Assoc J. 1983; 44: 161. https://doi.org/10.1080/15298668391404581
  10. Oommen VG, Knowles M, Zhao I. Should health service managers embrace open plan work environments? a review. Asia Pacific Journal of Health Management, 2008; 3(2): 37-43.
  11. Kim YS, Lee EG, Yup MJ, Kim KY. Distribution and classification of indoor concentration of microorganisms in public buildings. Kor J Env Hlth. Soc. 2002; 28(1): 85-92.
  12. Lee CM, Kim YS, Lee TH, Park WS, Hong SC. Characterization of airborne bioaerosol concentration in public facilities. J Environ Sci. 2004; 13(3); 215-222. https://doi.org/10.5322/JES.2004.13.3.215
  13. Kim KY, Roh YM, Kim YS, Lee CM, Sim IS. Profile of airborne microorganisms distributed in general offices. J Korean Soc Occup Environ Hyg. 2008; 18(1): 11-19.
  14. Tsai FC, Macher JM. Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study. Indoor Air. 2005; 15(9): 71-81. https://doi.org/10.1111/j.1600-0668.2005.00346.x
  15. Sessa R, Di PM, Schiavoni G, Santino I, Altieri A, Pinelli S, Del PM. Microbiological indoor air quality in healthy buildings. New Microbiol. 2002; 25(1): 51-56.
  16. Keum JS, Kim YS, Kim JD. Air Conditioning. Taehoon Publisher. 2000; 22.
  17. Ministry of knowledge economy, Revising the energy utilization act. Paragraph 2 of Article 7 No. 9, 2010.
  18. Ikeda K. Indoor air pollution causes and countermeasures. Sudopremium engineering Publisher; 2004. p.15-86.
  19. American society of refrigerating and air conditioning engineers (ASHRAE). Thermal environment conditions for human occupancy. Atlanta, ASHRAE, Inc; 1992.
  20. Jeong JY, Lee BK, Phee YG. Assessment of indoor air quality in commercial office buildings. J Korean Soc Occup Environ Hyg. 2007; 17(1): 31-42.
  21. Jeong JY, Lee KY, Lee BK, Phee YG. Office air quality assessment and management standards development (I). The Korea Occupational Safety and Health Agency (KOSHA); 2004.
  22. Lee KH, JO YJ, HA MK. Affect of indoor environment on worker's health in office buildingsfocusing on self-reported health symptoms of workers -. The Architectural Institute of Korea, 2006; 22(12): 37-44.
  23. Erdmann CA, Steiner KC, Apte MG. Inoor carbon dioxide concentrations and sick building syndrome symptoms in the base study. Indoor Air J USA, 2002.
  24. Nevalainen A, Hyvarinen A, Pasanen A, Reponen T. Fungi and bacteria in normal andmouldy dwellings. In: Samson, R.A., Flannigan, B., Flannigan ME, Verhoeff AP, Adan OCG, Hoekstra ES (Eds.), Health Implications of Fungi in Indoor Environments. 1994; 155-162.
  25. ASHRAE 62-2001, Handbook-HVAC application. Atlanta, ASHRAE Inc.; 2003.
  26. Morey PJ, Otten HB. Airborne viable microorganism in office environments sampling protocol and analytical procedures. Appl Ind Hyg. 1986; 1(1): 19.
  27. Bonetta S, Bonetta S, Mosso S, Samp S, Carraro E. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system. Environ Monit Assess. 2010; 161: 473-483. https://doi.org/10.1007/s10661-009-0761-8
  28. Hawng SH, Yoo KN, Park JH, Park DU, Yoon CS. Exposure level of airborne bacteria in the university laboratories in seoul, Korea. Kor J Env Hlth. 2009; 35(5): 355-361.
  29. Hwang SH, Park DU, Ha KC, Cho HW, Yoon CS. Airborne bacteria concentrations and related factors at university laboratories, hospital diagnostic laboratories and a biowaste site. J Clin Pathol. 2011; 64(3): 264-264.
  30. Myatt TA, Johnston SL, Zuo Z, Wand M, Kebadze T, Rudnick S, et al. Detection of airborne rhinovirus and its relation to outdoor air supply in office environments. Am J Respir Crit Care Med. 2004; 169(11): 1187-1190. https://doi.org/10.1164/rccm.200306-760OC
  31. Yoon HK, Park HS. Analyzing the state of the art office planning directions in north america for better productivity. Journal of the Korean Institute of Interior Design, 2010; 19(1): 78.
  32. International Facility Management Association, Research Report #18: Benchmarks III; 1997.