DOI QR코드

DOI QR Code

Disposable Nitrate-Selective Optical Sensor Based on Fluorescent Dye

  • Kim, Gi-Young (National Academy of Agricultural Science) ;
  • Sudduth, Kenneth A. (USDA-ARS Cropping Systems and Water Quality Research Unit) ;
  • Grant, Sheila A. (Biological Engineering,University of Missouri) ;
  • Kitchen, Newell R. (USDA-ARS Cropping Systems and Water Quality Research Unit)
  • 투고 : 2012.06.23
  • 심사 : 2012.06.29
  • 발행 : 2012.06.30

초록

Purpose: This study was performed to develop a simple, disposable thin-film optical nitrate sensor. Methods: The sensor was fabricated by applying a nitrate-selective polymer membrane on the surface of a thin polyester film. The membrane was composed of polyvinylchloride (PVC), plasticizer, fluorescent dye, and nitrate-selective ionophore. Fluorescence intensity of the sensor increased on contact with a nitrate solution. The fluorescence response of the optical nitrate sensor was measured with a commercial fluorospectrometer. Results: The optical sensor exhibited linear response over four concentration decades. Conclusions: Nitrate ion concentrations in plant nutrient solutions can be determined by direct optical measurements without any conditioning before measurements.

키워드

참고문헌

  1. Heng, L. Y. and E. A. H. Hall. 2001. Assessing a photocured self-plasticised acrylic membrane recipe for $Na^{+}$ and $K^{+}$ ion selective electrodes. Analytica Chimica Acta 443:25-40. https://doi.org/10.1016/S0003-2670(01)01195-3
  2. Huber, C., T. Werner, C. Krause and O. S. Wolfbeis. 1999. Novel chloride-selective optode based on polymerstabilised emulsions doped with a lipophilic fluorescent polarity-sensitive dye. Analyst 124:1617-1622. https://doi.org/10.1039/a905260g
  3. Huber, C., I. Klimant, C. Krause, T. Werner and O. S. Wolfbeis. 2001. Nitrate-selective optical sensor applying a lipophilic fluorescent potential-sensitive dye. Analytica Chimica Acta 449:81-93. https://doi.org/10.1016/S0003-2670(01)01363-0
  4. Koncki, R., S. Glab, J. Dziwulska, I. Palchetti and M. Mascini. 1999. Disposable strip potentiometric electrodes with solvent-polymeric ion-selective membranes fabricated using screen-printing technology. Analytica Chimica Acta 385:451-459. https://doi.org/10.1016/S0003-2670(98)00726-0
  5. Lee, D. K., H. J. Lee, G. S. Cha, H. Nam and K. J. Paeng. 2000. Ion chromatography detector based on solid-state ion-selective electrode array. Journal of Chromatography A 902:337-343. https://doi.org/10.1016/S0021-9673(00)00844-X
  6. Mohr, G. J., T. Werner and O. S. Wolfbeis. 1995. Application of a novel lipophilized fluorescent dye in an optical nitrate sensor. Journal of Fluorescence 5(2): 135-138. https://doi.org/10.1007/BF00727530
  7. Mohr, G. J. and O. S. Wolfbeis. 1996. Optical nitrite sensor based on a potential-sensitive dye and a mitrite - selective carrier. Analyst 121:1489-1494. https://doi.org/10.1039/an9962101489
  8. Mohr, G. J., F. Lehmann, R. Ostereich, I. Murkovic and O. S. Wolfbeis. 1997. Investigation of potential-sensitive fluorescent dyes for application in nitrate sensitive polymer membranes. Fresenius' Journal of Analytical Chemistry 357:284-291. https://doi.org/10.1007/s002160050154
  9. Mourzina, Y. G., J. Schubert, W. Zander, A. Legin, Y. G. Vlasov, H. Luth and M. J. Schoning. 2001. Development of multisensor systems based on chalcogenide thin film chemical sensors for the simultaneous multicomponent analysis of metal ions in complex solutions. Electrochimca Acta 47:251-258. https://doi.org/10.1016/S0013-4686(01)00563-1
  10. $Ro{\beta}$, B., G. Steiner, M. Kiesshauer, M. Bradter and K. Cammann. 1995. Instrument with integrated sensors for a rapod determination of inorganic ions. Sensors and Actuators B: Chemical 26:380-383.
  11. Ryan, J and P. Urayama. 2012. Characterizing the dualwavelength dye indo-1 for calcium-ion sensing under pressure. Analytical Methods 4:80-84. https://doi.org/10.1039/c1ay05486d
  12. Stromberg, N and S. Hulth. 2005. Assessing an imaging ammonium sensor using time correlated pixel-bypixel calibration. Analytica Chimica Acta 550:61-68. https://doi.org/10.1016/j.aca.2005.06.074
  13. Uhlig, A., F. Dietrich, E. Lindner, U. Schnakenberg and R. Hintsche. 1996. Miniaturised ion-selective sensor chip for potassium measurement in a biomedical application. Sensors and Actuators B: Chemical 34:252-257. https://doi.org/10.1016/S0925-4005(96)01831-X
  14. Zhu, J. Z., J. F. Xie, D. R. Lu, G. X. Zhang and Z. R. Zhang. 2000. Micromachined glucose sensor and $K^{+}$ ISE based on containment array. Sensors and Actuators B: Chemical 65:157-159. https://doi.org/10.1016/S0925-4005(99)00432-3

피인용 문헌

  1. Development of an Agricultural Data Middleware to Integrate Multiple Sensor Networks for an Farm Environment Monitoring System vol.38, pp.1, 2013, https://doi.org/10.5307/JBE.2013.38.1.025
  2. Biosensors Used for Quantification of Nitrates in Plants vol.2016, 2016, https://doi.org/10.1155/2016/1630695