DOI QR코드

DOI QR Code

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (I): Optimal Design of Ring-shaped Flab Valve Module

바이오용 압전디스크방식 마이크로 펌프 설계 및 제작(I) -링형 플랩밸브 모듈의 최적설계-

  • 김형진 (강원대학교 기계메카트로닉스공학과 대학원) ;
  • 서영호 (강원대학교 기계메카트로닉스공학과) ;
  • 김병희 (강원대학교 기계메카트로닉스공학과)
  • Received : 2011.07.08
  • Accepted : 2011.12.29
  • Published : 2012.06.15

Abstract

Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, it has some intrinsic disadvantages such as backward flow, pulsation of flow, low repeatability and producibility, and high cost. To overcome these limitation, a PZT disc actuated micro pump including a novel ring-shaped multi-flap check valve is introduced. To enhance the performance of the micro pump, the static behaviour of flap valve module and the micro fluidic behavior of fluids are numerically modelled and analyzed. As results of the numerical analysis, the optimal dimension and configuration of the ring-shaped multi flap valve are $1{\times}0.05$ mm and 2 (inlet side)${\times}1$ (outlet side) type. The obtained maximum flow rates and flow resolution are about 90 ml/min and 30 ${\mu}l$/stroke respectively.

Keywords

References

  1. Woias, P., 2005, "Micropumps-past, Progress and Future Prospects," Sensors and Actuators B, Vol. 105, No. 1, pp. 28-38. https://doi.org/10.1016/S0925-4005(04)00108-X
  2. Smits, J. G., 1990, "Piezoelectric Micropump with Three Valves Working Peristaltically," Sensors and Actuators A, Vol. 21-23, No. 1-3, pp. 203-206.
  3. van Lintel, H. T. G., van De Pol, F. C. M., and Bouwstra, S., 1988, "A Piezoelectric Micropump based on Micromachining of Silicon," Sensors and Actuators A, Vol. 15, No. 2, pp. 153-167. https://doi.org/10.1016/0250-6874(88)87005-7
  4. Yang, X., Zhou, Z., Cho, H., and Luo, X., 2006, "Study on a PZT-actuated Diaphragm Pump for Air Supply for Micro Fuel Cells," Sensors and Actuators A, Vol. 130-131, pp. 531-536. https://doi.org/10.1016/j.sna.2005.12.021
  5. Kan, J., Yang, Z., Peng, T., Cheng, G., and Wu, B., 2005, "Design and Test of a High-performance Piezoelectric Micropump for Drug Delivery," Sensors and Actuators A, Vol. 121, No. 1, pp. 156-161. https://doi.org/10.1016/j.sna.2004.12.002
  6. Liua, G., Shen, C., Yang, Z., Cai, X., and Zhang, H., 2010, "A Disposable Piezoelectric Micropump with High Performance for Closed-loop Insulin Therapy System," Sensors and Actuators A, Vol. 163, No. 1, pp. 291-296. https://doi.org/10.1016/j.sna.2010.06.030
  7. Cooney, C. G., and Towe, B. C., 2004, "A Thermopneumatic Dispensing Micropump," Sensors and Actuators A, Vol. 116, No. 3, pp. 519-524. https://doi.org/10.1016/j.sna.2004.05.015
  8. Jun, D. H., Sim, W. Y., and Yang, S. S., 2007, "A Novel Constant Delivery Thermopneumatic Micropump using Surface Tensions," Sensors and Actuators A, Vol. 139, No. 1-2, pp. 210-215. https://doi.org/10.1016/j.sna.2007.04.038
  9. Van de Pol, F. C. M., Van Lintel, H. T. G., Elwenspoek, M., and Fluitman, J. H. J., 1990, "A Thermopneumatic Micropump based on Micro-engineering Techniques," Sensors and Actuators A, Vol. 21, No. 1-3, pp. 198-202. https://doi.org/10.1016/0924-4247(90)85038-6
  10. Luo, A., and Xia, A., 2005, "A Novel Valve-less Synthetic-jet-based Micro-pump," Sensors and Actuators A, Vol. 122, No. 1, pp. 131-140. https://doi.org/10.1016/j.sna.2005.03.062
  11. Bourouina, T., Bosseboeuf, A., and Grandchamp, J. P., 1997, "Design and Simulation of an Electrostatic Micropump for Drug-delivery Applications," J. Micromech. Microeng., Vol. 7, No. 3, pp. 186-188. https://doi.org/10.1088/0960-1317/7/3/028
  12. Teymoori, M. M., and Abbaspour-Sani, E., 2005, "Design and Simulation of a Novel Electrostatic Peristaltic Micromachined Pump for Drug Delivery Applications," Sensors and Actuators A, Vol. 117, No. 2, pp. 222-229. https://doi.org/10.1016/j.sna.2004.06.025
  13. Tsai, J., and Lin, L., 2002, "Active Microfluidic Mixer and Gas Bubble Filter Driven by Thermal Bubble Micropump," Sensors and Actuators A, Vol. 97-98, pp. 665-671. https://doi.org/10.1016/S0924-4247(02)00031-6
  14. Chan, S., Chen, C., and Liu, C., 2010, "A Bubbleactivated Micropump with High-frequency Flow Reversal," Sensors and Actuators A, Vol. 163, No. 2, pp. 501-509. https://doi.org/10.1016/j.sna.2010.08.026
  15. Oshio, K., Watanabe, H., Song, Y., Verkman, A. S., and Manley, G. T., 2005, "Reduced Cerebrospinal Fluid Production and Intracranial Pressure in Mice Lacking Choroid Plexus Water Channel Aquaporin-1," FASEB J, Vol. 19, No. 1, pp. 76-78.

Cited by

  1. 자기공명영상 동적검사 시 조영제 역류방지용 밸브의 유용성 vol.20, pp.6, 2012, https://doi.org/10.5392/jkca.2020.20.06.439