Clinical image quality evaluation for panoramic radiography in Korean dental clinics

  • Choi, Bo-Ram (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Choi, Da-Hye (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Huh, Kyung-Hoe (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Yi, Won-Jin (Department of Oral and Maxillofacial Radiology, BK21 Craniomaxillofacial Life Science, and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Heo, Min-Suk (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Choi, Soon-Chul (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Bae, Kwang-Hak (Department of Preventive and Public Health Dentistry and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Lee, Sam-Sun (Department of Oral and Maxillofacial Radiology, BK21 Craniomaxillofacial Life Science, and Dental Research Institute, School of Dentistry, Seoul National University)
  • Received : 2012.06.12
  • Accepted : 2012.06.25
  • Published : 2012.09.30

Abstract

Purpose: The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods: Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results: A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion: Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.

Keywords

References

  1. American Dental Association, United States Department of Health and Human Services. The selection of patients for dental radiographic examinations. Revised 2004. Chicago: American Dental Association; 2004.
  2. Parsons DM, Kim Y, Haynor DR. Quality control of cathoderay tube monitors for medical imaging using a simple photometer. J Digit Imaging 1995; 8 : 10-20. https://doi.org/10.1007/BF03168051
  3. National Council on Radiation Protection & Measurements. NCRP report No. 145 - Radiation protection in dentistry. Bethesda: NCRP; 2003.
  4. European Commision [Internet]. Radiation protection 136: European guidelines on radioation protection in dental radiology [cited June 10]. Available from: http://ec.europa.eu/energy/ nuclear/radiation_protection/publications_en.htm.
  5. Enforcement regulations of the installation and operation of special medical equipments. Enforcement regulation No.65 of Ministry of Health and Welfare, 2003.
  6. Kim EK. Development of diagnostic reference level in dental x-ray examination in Korea. Final report. Seoul: Korea Food & Drug Adnimistration; 2009 Nov. Report No. 09142Radiology510.
  7. Choi JI, Na DG, Kim HH, Shin YM, Ahn KJ, Lee JY. Quality control of medical imaging. J Korean Radiol Soc 2004; 50 : 317-31.
  8. Lee SH, Choe YH, Chung SY, Kim MH, Kim EK, Oh KK, et al. Establishment of quality assessment standard for mammographic equipments: evaluation of phantom and clinical images. J Korean Radiol Soc 2005; 53 : 117-27.
  9. White SC, Pharoah MJ. Oral Radiology. Principles and Interpretation. 6th ed. St. Louis: Mosby-Year Book Inc; 2009. p. 175-90.
  10. Kim HJ. A study on guidance for medical radiation safety. Final report: Korea Food & Drug Adnimistration; 2010 Dec. Report No. 10171Radiology457.
  11. Choi DH. A study of clinical evaluation reference and imaging standardization for panoramic imaging [dissertation]. Seoul: Seoul National University; 2012.

Cited by

  1. 파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전 vol.30, pp.1, 2012, https://doi.org/10.14368/jdras.2014.30.1.1
  2. Descriptive study of mandibular canal visibility: morphometric and densitometric analysis for digital panoramic radiographs vol.45, pp.7, 2012, https://doi.org/10.1259/dmfr.20160079
  3. Assessment of panoral radiograph quality in a dental treatment center vol.6, pp.2, 2016, https://doi.org/10.4103/2321-1407.177960
  4. The limit values for brightness and contrast adjustment in digital panoramic radiography vol.884, pp.None, 2012, https://doi.org/10.1088/1742-6596/884/1/012044
  5. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis vol.884, pp.None, 2012, https://doi.org/10.1088/1742-6596/884/1/012045
  6. Efficacy of the Monte Carlo method and dose reduction strategies in paediatric panoramic radiography vol.9, pp.None, 2019, https://doi.org/10.1038/s41598-019-46157-0