3D simulation and CAD/CAM in orthognathic surgery

임상가를 위한 특집 1 - 턱교정수술에서3D simulation과 CAD/CAM의 활용

  • Jin, ImGeun (Dept. of Oral and Maxillofacial Surgery, School of Dentisty, Seoul National University) ;
  • Yang, HoonJoo (Dept. of Oral and Maxillofacial Surgery, School of Dentisty, Seoul National University) ;
  • Kim, DeaSeung (Interdisciplinary Program in Radiation Applied Life Science major, College of Medicine, Seoul National University) ;
  • Yi, Won Jin (Interdisciplinary Program in Radiation Applied Life Science major, College of Medicine, Seoul National University) ;
  • Hwang, Soon Jung (Dept. of Oral and Maxillofacial Surgery, School of Dentisty, Seoul National University)
  • 진임건 (서울대학교 치의학대학원/치과병원 구강악안면외과) ;
  • 양훈주 (서울대학교 치의학대학원/치과병원 구강악안면외과) ;
  • 김대승 (서울대학교 의과대학 방사선응용생명과학전공) ;
  • 이원진 (서울대학교 의과대학 방사선응용생명과학전공) ;
  • 황순정 (서울대학교 치의학대학원/치과병원 구강악안면외과)
  • Received : 2012.10.16
  • Accepted : 2012.10.19
  • Published : 2012.11.01

Abstract

We describes the process of 3D virtual treatment planning and of CAD/CAM for surgical splint in orthognathic surgery. The potential benefits and disadvantages of 3D virtual approach and the use of CAD/CAM system for the treatment of the patient with a maxillofacial deformity are discussed. For the more convenient applications,3D software should be improved.

Keywords

References

  1. Gateno, J., et al. (2003). The precision of computer-generated surgical splints. J Oral Maxillofac Surg 61(7): 814-817. https://doi.org/10.1016/S0278-2391(03)00240-4
  2. Swennen GRJ, Mollemans W, Schutyser F. (2009). Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging. J Oral Maxillofac Surg 67(10): 2080-2092. https://doi.org/10.1016/j.joms.2009.06.007
  3. Swennen GRJ, Mollemans W, Schutyser F. (2007). The use of a new 3D splint and double CT scan procedure to obtain an accurate anatomic virtual augmented model of the skull. Int J Oral Maxillofac Surg 36: 146-152 https://doi.org/10.1016/j.ijom.2006.09.019
  4. Swennen GR, Mommaerts MY, Abeloos J, De Clercq C, Lamoral P, Neyt N, Casselman J, Schutyser F (2008).A cone-beam CT based technique to augment the 3D virtual skull model with a detailed dental surface.Int J Oral Maxillofac Surg. 2009 Jan;38(1):48-57. Epub 2008 Dec 31. https://doi.org/10.1016/j.ijom.2008.11.006
  5. Mori Y, Shimizu H, Minami K, Kwon TG, Mano T. (2011). Development of a simulation system in mandibular orthognathic surgery based on integrated three-dimensional data. Oral Maxillofac Surg 15(3): 131-138. https://doi.org/10.1007/s10006-010-0247-4
  6. Caloss R, Atkins K, Stella JP (2007). Three- Dimensional Imaging for Virtual Assessment and Treatment Simulation in Orthognathic Surgery. Oral Maxillofacial Surg Clin N Am 19; 287-309 https://doi.org/10.1016/j.coms.2007.04.006
  7. Cevidanes LHC, Tucker S, Styner M,et al.(2010) Three-dimensional surgical simulation. Am J Orthod Dentofacial Orthop 138:361-71 https://doi.org/10.1016/j.ajodo.2009.08.026
  8. Aboul-Hosn Centenero S, Hern?ndez-Alfaro F (2011). 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - our experience in 16 cases. J Craniomaxillofac Surg. 2012 Feb;40(2):162-8. Epub 2011 Mar 31. https://doi.org/10.1016/j.jcms.2011.03.014
  9. Uechi J, Okayama M, Shibata T, Muguruma T, Hayashi K, Endo K, Mizoguchi I (2006). A novel method for the 3-dimensional simulation of orthognathic surgery by using a multimodal imagefusion technique. Am J Orthod Dentofacial Orthop. 130(6):786-98. https://doi.org/10.1016/j.ajodo.2006.03.025
  10. Chapuis J, Schramm A, Pappas I, Hallermann W, Schwenzer-Zimmerer K, Langlotz F, Caversaccio M (2007). A new system for computer-aided preoperative planning and intraoperative navigation during corrective jaw surgery. IEEE Trans Inf Technol Biomed. 11(3):274-87. https://doi.org/10.1109/TITB.2006.884372
  11. Fuhrmann RA, Frohber U, Diedrich PR. (1994). Treatment prediction with three-dimensional computer tomographic skull models. Am J Orthod Dentofacial Orthop 106(2): 156-160. https://doi.org/10.1016/S0889-5406(94)70033-8