DOI QR코드

DOI QR Code

진공복층 유리와 3중 유리의 결로 위험성 평가

The Condensation Risk Assessment of Vacuum Multi-Layer Glass and Triple Glass using the Temperature Difference Ratio

  • 원종서 (대림산업(주) 기술개발원) ;
  • 남중우 (대림산업(주) 기술개발원)
  • Won, Jong-Seo (Technology Research and Development Institute, Daelim Industrial Co. Ltd.) ;
  • Nam, Jung-Woo (Technology Research and Development Institute, Daelim Industrial Co. Ltd.)
  • 투고 : 2013.08.01
  • 발행 : 2013.11.10

초록

An external window directly affects the energy performance of its building. In modern well-insulated buildings, U-values for walls of 0.36 $W/m^2K$ or even lower can be realized. In such buildings, glazing with typical U-value of 2.1 $W/m^2K$ or higher creates thermal weak spots on the facade. The performance of the existing triple glass window has been limited to energy savings and condensation prevention. In this study, the performance of condensation prevention of a vacuum multi-layer glass was analyzed. The final conclusion through mock-up experiments is as follows. The surface temperature of the vacuum multi-layer glass was $2^{\circ}C$ higher, and the temperature difference ratio (TDR) was 0.07 lower, than the corresponding values of the triple glass.

키워드

참고문헌

  1. Nam, J. W. and Won, J. S., 2011, A comparative study on the vacuum multi-layer glass and triple glass through the performance test of condensation, Proceedings of SAREK, ʼ11 Summer Annual Conference, pp. 424-427.
  2. Cho, S. W. and Tae, C. S., 2000, Experimental study on thermal performance of large size vacuum glazings, Proceedings of SAREK, ʼ00 Summer Annual Conference pp. 37-41.
  3. Nam, J. W. and Won, J. S., 2011, Evaluation of condensation resistance performance on the front door of reduced thermal bridges, Proceedings of KIEAE, Vol. 21, pp. 395-398.
  4. Nam, J. W. and Won, J. S., 2010, A study on the protection of condensation of the front Door connection depending on anti-thermal bridge details, Proceedings of KIEAE, Vol. 19, pp. 139-142.
  5. KS F 2295:2004, Test method of dew condensation for window and doors.
  6. Woutesrs, P., Schietecat, J., and Standaert, P., 2003, Practical guide for the hygrothermal evaluation of thermal bridges, Eurokobra project document 07-05-2003.