  • Published : 2013.10.31

Abstract

This study creates the evaluation criteria to analyze the $CO_2$ emission quantity in the complex of apartment house among domestic buildings and proposes how to calculate the $CO_2$ emission quantity by the only simple information of apartment house. The study shows that in order to create the index of carbon emission evaluation criteria, $CO_2$ emission quantity for its input materials in these 27 apartment houses are 445,412g-$CO_2/m^2$ for apartment building, 474,322g-$CO_2/m^2$ for the basement parking lot, 483,523g-$CO_2/m^2$ for welfare facility, 729,957g-$CO_2/m^2$ for sales facility, 743,560g-$CO_2/m^2$ for other facility, 26,782g-$CO_2/m^2$ for public facility, 43,659g-$CO_2/m^2$ for landscape, 1,113g-$CO_2/m^2$ for indoor facility, 11,251g-$CO_2/m^2$ for outdoor facility and 891g-$CO_2/m^2$ for common temporary based on the average $CO_2$ emission by facility. We can also see the analysis data that in case of using the selected factors only, the rate of error is 7.51% comparing with the emission quantity by using simplified LCA method this study suggests for the whole range of apartment houses and the rate of error is average 3.24% using selective and main materials. And this it is evaluated that we can get the result which is similar to the actual $CO_2$ emission quantity with only the simple information about the apartment house.

Keywords

References

  1. The Bank of Korea 2008, Industry input-output table 2010
  2. Kim, Jong-yup, Kim, Sung-wan, and Sohn, Jang-yul, A Study on the Estimation of the Environmetal Load Intensity of Construction Materials for the Building LCA, Paper for Architectural institute of Korea, 2004;20(7):211-218
  3. Lee, Gang-hee, Yang, Jae-Hyuk, A Study on the Functional Unit Estimation of Energy Consumption and Carbon Dioxide Emission in the Construction Materials ,Paper for Architectural institute of Korea, 2009;25(6):43-50
  4. Woo, Jee-hwan and Shin, Seong-woo, The Environmental Load Comparison Evaluation of The Apartment House for Main Construction Materials of Standard Apartment House, paper of Architectural Institute of Korea Ecological Environment, 2010;10(1):85-90
  5. Ministry of Land, Infrastructure, and Transport, the Guideline calculation co2 emissions of the facilities -buildings-, 2011
  6. Daniel Kellenbergera, Hans-Jorg Althausb, Relevance of simplifications in LCA of buildingcomponents, Building and Environment, 2009:818-825
  7. Ignacio Zabalza Bribian, Antonio Valero Capilla, Alfonso Aranda Uson, Life cycle assessment of building materials: Comparative analysis of energy and environmental impacts and evaluation of the eco-efficiency improvement potential, Building and Environment, 2011:1133-1140
  8. Charlene Bayer, Michael Gamble, Russell Gentry, Surabhi Joshi, AIA Guide to Building Life Cycle Assessment in Practice, Georgia Institute of Technology, 2010
  9. ISO 14040, Environmental management - Life cycle assessment - Principles and framework, 2006