DOI QR코드

DOI QR Code

A Study of Hood-Type Vertical Axis Wind Turbine Embedded to Highway Median Strip

도로 중앙분리대용 후드장식형 수직축풍력발전기 연구

  • Lee, Jong-Jo (Department of Energy Engineering, Chonbuk National University) ;
  • Lim, Jae-Kyoo (Department of Mechanical Design Engineering, Chonbuk National University)
  • 이종조 (전북대학교 대학원 에너지공학과) ;
  • 임재규 (전북대학교 기계설계공학부)
  • Received : 2012.09.11
  • Accepted : 2013.01.08
  • Published : 2013.01.31

Abstract

This paper introduces the study of hood-type wind turbine embedded on highway median strip. Recently, many studies are being made to apply to small wind turbine in city. This study is wind turbine producing electricity generated from the wind by running cars. In order to analyze wind generated by running cars, we measured experiments using running cars and buses. Also, using CFD and interpreter program, we analysis wind turbines performance and applied to the twist-sabonius blade. This wind turbine attached to safety lamp on the road is produced to use electricity generated through the wind tunnel experiment. In this paper results, this wind turbine system is expected to produce the power source installed the heat ray and safety lamps on the road.

Keywords

References

  1. Kim Hyun-Goo, Woo Sang-Woo, Jang Moon-Seok, Shin Hyung-Ki, "Computational Flow Analysis on Applicability of Vehicle-Induced Wind to Highway to Wind Power Generation" Journal of The Korean Society for New and Renewable Energy, Vol.4, No.4, pp.30-36, 2008.
  2. Lee Jeong-Ick, Kim Jin-Soo, "Development of Practical Education Program by Construction of the Wind Power System Using the Wind by Car". Proceedings of KSMT 2002 Summer Annual Meeting, pp.39-44, 2002.
  3. Jeon Joong-Hwan, "Introduction to wind turbine technology", Journal of The Korean Physical Society, pp.50 -54, 2006.
  4. Park Jun-Yong, "An Experimental Study on the Aerodynamic Performance of High-efficient, Small-scale, Vertical-axis Wind Turbine", Inha University, pp.3-46, 2009.
  5. Chung Sang-Hoon, Chung Kwang-Seop, Kim Chul-Ho, "Development of a Cross-flow Type Vertical Wind Power Generation System for Electric Energy Generation Using Convergent-Divergent Duct", Journal of Air-conditioning and refrigerating engineers of Korea, Vol.23, No.8, pp.543 -548, 2011. https://doi.org/10.6110/KJACR.2011.23.8.543
  6. Yoon Seong-Wook, Jeon Wan-Ho, Kim Hyun-Goo, "Feasibility Analysis on Wind Turbine Embedded to Highway Median Strip - Consideration on Vehicle Drag Coefficient", Journal of The Korean Society for New and Renewable Energy, pp.536-538, 2009. https://doi.org/10.1063/1.3183486