DOI QR코드

DOI QR Code

A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio

축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구

  • Received : 2013.09.24
  • Accepted : 2013.12.06
  • Published : 2013.12.31

Abstract

This study, to evaluate the technology of the fire resistance design of Reinforced Concrete columns based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation using heat transfer analysis and Heat-load test of the Reinforced Concrete columns as parameter is the axial load ratio. In accordance with axial load without eccentricity, the load ratio of 0.30, 0.35, 0.40 and 0.47 were imposed on columns. As a result of this study, 0.40 or more of axial load ratio can be ensured that the fire resistance performance was considered satisfactory.

본 연구의 목적은 성능적 내화설계를 기반으로 한 철근콘크리트 기둥의 내화성능 평가를 최종 목표로 철근콘크리트 기둥의 열전달 해석을 통한 온도분포와 재하가열실험을 통한 수축량으로 적정 축력비를 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. 편심이 전혀 없는 순수축력을 기준으로 축력비 0.30, 0.35, 0.40, 0.47을 재하한 결과, 0.40 이상의 축력비를 확보하여야 내화성능을 만족할 수 있다고 판단하였다.

Keywords

References

  1. I. K. Kwon, "Study on Fire Resistance According to Load Ratio for Composite Structural Elements Filled with Concrete", Journal of Architectural Institute of Korea, Vol. 26, No. 6, pp. 69-76 (2010).
  2. I. H. Yeo, "A Proposal for Load Ratio of Reinforced Concrete Column Subjected to Standard Fire", University of Seoul (2012).
  3. S. H. Park, K. C. Song, K. S. Jung, H. Y. Kim, Y. I. Won and S. M. Choi, "Effect of Thermal Properties of Structural Materials on the Fire Resistance of Concrete-Filled Steel Tube Column under Constant Axial Loads", Journal of Architectural Institute of Korea, Vol. 28, No. 1, pp. 325-328 (2008).
  4. K. J. Hwang and S. K. Yoon, "Determination of the Fire Protection Thickness of CFT Column Using Heat Transfer Analysis", Journal of Architectural Institute of Korea, Vol. 29, No. 6, pp. 65-72 (2013).
  5. EUROCODE 3, Design of Steel Structures - Part 1.2 General actions - Actions on structures exposed to fire (2002).
  6. EUROCODE 4, Design of Composite Steel and Concrete -Part 1.2 General rules - Structural fire design (2005).
  7. Korean Standards Association, KS F 2257-1 : Methods fire resistance test for elements of building construction -General requirements (2005).
  8. Korean Standards Association, KS F 2257-7 : Methods fire resistance test for elements of building construction -Specific requirements for columns (2006).
  9. ABAQUS/CAE User's Manual Version 6.5, Hibit, Karlsson & Sorensen, lnc (2005).
  10. ABAQUS/CAE Analysis User's Manual Version 6.5, Hibit, Karlsson & Sorensen, lnc (2005).
  11. ABAQUS/CAE Theory Manual Version 6.5, Hibit, Karlsson & Sorensen, lnc (2005).