DOI QR코드

DOI QR Code

Input AC Voltage Sensorless Control for a Three-Phase Z-Source PWM Rectifier

3상 Z-소스 PWM 정류기의 입력 AC 전압 센서리스 제어

  • Han, Keun-Woo (Dept. of Electrical Engineering, Chonnam National University) ;
  • Jung, Young-Gook (Dept. of Electrical Engineering, Daebul University) ;
  • Lim, Young-Cheol (Dept. of Electrical Engineering, Chonnam National University)
  • 한근우 (전남대학교 전기공학과) ;
  • 정영국 (대불대학교 융합기술학부) ;
  • 임영철 (전남대학교 전기공학과)
  • Received : 2012.12.24
  • Accepted : 2013.02.27
  • Published : 2013.03.01

Abstract

Respect to the input AC voltage and output DC voltage, conventional three-phase PWM rectifier is classified as the voltage type rectifier with boost capability and the current type rectifier voltage with buck capability. Conventional PWM rectifier can not at the same time the boost and buck capability and its bridge is weak in the shoot- through state. These problems can be solved by Z-source PWM rectifier which has all characteristic of voltage and current type PWM rectifier. By shoot-through duty ratio control, the Z-source PWM rectifier can buck and boost at the same time, also, there is no need to consider the dead time. This paper proposes the input AC voltage sensorless control method of a three-phase Z-source PWM rectifier in order to accomplish the unity input power factor and output DC voltage control. The proposed method is estimated the input AC voltage by using input AC current and output DC voltage, hence, the sensor for the input AC voltage detection is no needed. comparison of the estimated and detected input AC voltage, estimated phase angle of the input voltage, the output DC voltage response for reference value, unity power factor, FFT(Fast Fourier Transform) of the estimated voltage and efficiency are verified by PSIM simulation.

Keywords

References

  1. R. Wu, S. B. Dewan, and G. R. Slemon, "Analysis of an ac-to-dc voltage source converter using PWM with phase and amplitude control," IEEE Trans. Ind. Appl., vol. 27, no.2, pp. 355-364, Mar./Apr. 1991. https://doi.org/10.1109/28.73626
  2. V. Kaura, and V. Blasko, "Operation of a voltage source converter at increased utility voltage," IEEE Trans. Power Electron., vol. 12, pp. 132-137, Jan. 1997. https://doi.org/10.1109/63.554178
  3. V. Blasko, and V. Kaura, "A new mathematical model and control of a three-phase AC-DC voltage source converter," IEEE Trans. Power Electron., vol. 12, pp. 116-123, Jan. 1997. https://doi.org/10.1109/63.554176
  4. Xinping Ding, Zhaoming Qian, Yeyuan Xie, Zhengyu Lu, "Three phase Z-source rectifier," in Proc. IEEE PESC '05. IEEE., pp. 494-500, Jun. 2005.
  5. D. M. Vilathgamuwa, P. C. Loh and K. Karunakar, "Modelling of three phase Z-source boost-buck rectifiers," in Conf IEEE PEDS., pp. 1471-1476, Nov. 2007.
  6. K. Karunakar and D. M.Vilathgamuwa, "Dynamic analysis of three phase Z-source boost-buck rectifier," in Conf, IEEE PECon., pp. 198-202, Dec. 2008.
  7. F. Z. Peng, "Z-source inverter," IEEE Trans. Ind. Applicat., vol. 39, No.2, pp. 504-510, March/April 2003. https://doi.org/10.1109/TIA.2003.808920
  8. T. Ohnishi and K. Fujii, "Line voltage sensorless three phase PWM converter by tracking control of operating frequency," in Conf. Rec. of Power Conversion Conference, 1997, vol. 1, pp. 247-252.
  9. T. Noguchi, H. Tomiki, S. Kondo, and I. Takahashi, "Direct power control of PWM converter without power-source voltage sensors," IEEE Trans Ind. Applicat., vol. 34, no.3, pp. 473-479, May./Jun. 1998. https://doi.org/10.1109/28.673716
  10. S. Hansen, M. Malinowski, F. Blaabjerg, and M. P. Kazmierkowski, "Sensorless control strategy for PWM rectifier," in Conf. Rec. of IEEE APEC'00, 2000, vol. 2, pp. 832-838.
  11. H. S. Song, I. W. Joo, and K. Nam, "Source Voltage Sensorless Estimation Scheme for PWM Rectifiers Under Unbalanced Conditions," IEEE Trans Ind. Electron., vol. 50, no.6, pp. 1238-1245, DEC. 2003. https://doi.org/10.1109/TIE.2003.819685
  12. H. Yoo, J. H. Kim, and S. K. Sul, "Sensorless Operation of a PWM Rectifier for a Distributed Generation," IEEE Trans Power Electron., vol. 22, no. 3, pp. 1014-1018, May. 2007 https://doi.org/10.1109/TPEL.2007.897094
  13. W. C. Lee, D. S. Hyun, and T. K. Lee, "A Novel control method for three-phase PWM rectifiers using a single current sensor," IEEE Trans Power Electron., vol. 15, no. 5, pp. 861-870, Sep. 2000 https://doi.org/10.1109/63.867675
  14. D. C. Lee, and D. S. Lim, "AC voltage and current sensorless control of three-phase PWM rectifier," IEEE Trans Power Electron., vol. 17, no. 6, pp. 883-890, Nov. 2002 https://doi.org/10.1109/TPEL.2002.805592
  15. H. Kim, and T. M. Jahns, "Phase current reconstruction for AC motor drives using a DC link single current sensor and measurement voltage vectors," IEEE Trans Power Electron., vol. 21, no. 5, pp. 1413-1419. Sept. 2006 https://doi.org/10.1109/TPEL.2006.880262
  16. G. Lo Calzo, A. Lidozzi, L. Solero, and F. Crescimbini, "Three-phase Z-source power supply design and dynamic modeling," in Conf. Rec. of IEEE ECCE'11, 2011, pp. 1339-1345.
  17. Tae-Won Chun, Quang-Vinh Tran, Jung-Ryol Ahn, and Jih-Sheng Lai, "AC output voltage control with minimization of voltage stress across devices in the Z-source inverter using modified SVPWM", in Conf. Rec. of IEEE PESC'06, 2006, pp. 1-5.
  18. Se-Jin Kim, Young-Gook Jung, Young-Cheol Lim, and Seung-Hak Yang, "Output AC voltage control of a three-phase Z-source inverter by the voltage gain and modulation index control", Trans. KIEE, vol. 59, no. 11, pp. 1996-2005. Nov. 2010