Abstract
Recently, the waste heat recovery technique using thermoelectric generator (TEG) in automotive engine has emerged to improve thermal efficiency in commercial vehicle. It is not difficult to recognize the numerous attempts that have been made to develop the TEG simulation model, but it is hard to find the model in conjunction with a particular heat engine system. In this study, 1-D commercial software AMESim was used to develop a computational model that can assess waste heat recovery from a diesel engine exhaust using TEG. The developed TEG simulation model can be used for evaluating the TEG performance of various types of TE module, and the diesel engine model can simulate any type of on and off-road diesel engines. The simulation results demonstrated that approximately 544.75W could be recovered from the engine exhaust and 40.4W could be directly converted into electricity using one TE module. The models developed in this study can be easily coupled with each other in the same computational program; thus, the models are expected to provide a viable tool for developing and optimizing a TEG waste heat recovery system in an automotive diesel engine.
최근 엔진 효율 향상을 위하여 열전 소자를 이용한 자동차 엔진 폐열 회수 기술이 주목 받고 있다. 열전소자 해석 모델링은 많이 개발 되었으나, 특정한 시스템 해석 모델과 함께 적용된 사례는 찾아보기 어렵다. 따라서, 본 연구에서는 열전소자를 이용하여 디젤 엔진의 배기 폐열 에너지 회수율을 평가할 수 있는 해석 모델을 1-D 상용 프로그램인 AMESim을 이용하여 개발하였다. 개발한 열전소자 해석 모델은 다양한 소자 종류에 따른 열전 발전 효율 및 폐열 회수율 평가가 가능한 모델이며, 디젤 엔진 해석 모델은 현재 상용화된 모든 디젤 엔진을 모사할 수 있는 모델이다. 여러 운전 조건에서 디젤 엔진의 폐열로부터 하나의 열전소자를 사용하여 회수 가능한 에너지는 약 544.75W이고, 전기로 변환될 수 있는 동력은 약 40.4W이었다. 본 연구에서 개발한 해석 모델은 같은 해석 프로그램에서 연동하여 해석을 용이하게 수행할 수 있기에 추후 열전소자를 이용한 디젤 엔진의 배기 폐열 회수 시스템 개발 시 회수율을 예상하고 시스템 최적화를 수행할 수 있는 방법을 제공할 것으로 기대된다.