DOI QR코드

DOI QR Code

Design and Implementation of Robot-Based Alarm System of Emergency Situation Due to Falling of The Eldely

고령자 낙상에 의한 응급 상황의 4족 로봇 기반 알리미 시스템 설계 및 구현

  • 박철호 (한경대학교 전기전자제어공학과) ;
  • 임동하 (한경대학교 전기전자제어공학과) ;
  • 김남호 (한경대학교 바이오정보기술전문대학원) ;
  • 유윤섭 (한경대학교 전기전자제어공학과)
  • Received : 2012.09.27
  • Accepted : 2013.04.08
  • Published : 2013.04.30

Abstract

In this paper, we introduce a quadruped robot-based alarm system for monitoring the emergency situation due to falling in the elderly. Quadruped robot includes the FPGA Board(Field Programmable Gate Array) applying a red-color tracking algorithm. To detect a falling of the elderly, a sensor node is worn on chest and accelerations and angular velocities measured by the sensor node are transferred to quadruped robot, and then the emergency signal is transmitted to manager if a fall is detected. Manager controls the robot and then he judges the situation by monitoring the real-time images transmitted from the robot. If emergency situation is decided by the manager, he calls 119. When the fall detection system using only sensor nodes is used, sensitivity of 100% and specificity of 98.98% were measured. Using the combination of the fall detection system and portable camera (robot), the emergency situation was detected to 100 %.

본 논문에서는 노인의 낙상에 의한 위급상항을 모니터링 하기 위한 4족 로봇 및 모니터링 시스템을 소개한다. 4족 로봇은 FPGA Board(Field Programmable Gate Array)를 이용한 특정 색을 판별하는 영상처리에 기반하여 자율 이동한다. 노인의 낙상을 감지하기 위해 가슴에 센서노드를 착용하고, 낙상에 의한 응급 상황 시에 4족 로봇이 낙상신호를 관리자에게 전송한다. 관리자는 전송된 영상을 기반으로 4족 로봇을 제어 및 상황판단을 하고, 위급상황이면 119에 신고를 한다. 센서노드만을 사용한 낙상 감지 시스템에서 98.33% 낙상의 Sensitivity와 일상행동 94.375% Specificity가 측정 되었다. 100% 낙상 감지를 못했던 점을 낙상 감지 시스템과 이동형 카메라(로봇)의 결합 알고리즘을 제안 및 실험을 통해 100% 검증 하였다.

Keywords

References

  1. T. Zhang, J. Wang, L. Xu and P. Liu, "Fall detection by wearable sensor and one-class SVM algorithm," Lecture Notes in Control and Information Sciences, Vol. 345, pp. 858-863, 2006.
  2. M. Kangas, I. Vikman, J. Wiklander, P. Lindgren, L. Nyberg, T. Jamsa, "Sensitivity and specificity of fall detection in people aged 40 years and over," Gait & Posture, Vol. 29, pp. 571-574, 2009. https://doi.org/10.1016/j.gaitpost.2008.12.008
  3. T. Degen, H. Jaeckel, M. Rufer and S. Wyss, "SPEEDY: a fall detector in a wrist watch," in Proc. 7th IEEE Int. Symp. Wearable Computers, Oct. 2005, pp. 184-187.
  4. B. Kaluza and M. Lustrek, "Fall detection and activity recognition methods for the confidence project: A survey," in Proc. 12th International Multiconference Information Society 2008, Vol. A, pp. 22-25, 2008.
  5. 김남섭, "유비쿼터스 헬스케어를 위한 효율적인 낙상감지 기법," 한국정보기술학회논문지, 제8권, 제 8호, pp. 133-140, 2010.
  6. 김성현, 박진, 김동욱, 김남균, "가속도센서와 기울 기센서를 이용한 실시간 낙상 감지 시스템에 관한 연구," 한국정밀공학회지, 제28권, 제11호, pp. 1330-1338, 2011.
  7. B. U. Toreyin, Y. Dedeo lu and A. E. Cetin, "HMM Based Falling Person Detection Using Both Audio and Video," Lecture Notes in Computer Science, Vol. 3766, pp. 211-220, 2005.
  8. Z. Fu, T. Delbruck, P. Lichtsteiner, E. Culurciello, "An address-event fall detector for assisted living applications," IEEE Trans. Biomedical Circuits and Systems, Vol. 2, No. 2, pp. 88-96, 2008, https://doi.org/10.1109/TBCAS.2008.924448
  9. S.-G. Miaou, P.-H. Sung, and C.-Y. Huang, "A customized human fall detection system using omni-camera images and personal information," in Proc. 1st Distributed Diagnosis and Home Healthcare (D2H2) Conference, April 2006, pp. 39-42.
  10. 이윤재, "심전도, 가속도계, 자이로스코프를 이용한 고령자 응급상황 모니터링 시스템에 관한 연구", 한경대학교 대학원 석사학위 논문, 2011.
  11. M. Goonen, "Receiver operating characteristic (ROC) curves," in Proc. SUGI 31, March 2006, pp.210- 231.Available:http://www2.sas.com/proceedings/sugi 31/210-31.pdf.