DOI QR코드

DOI QR Code

Centralized Adaptive Under Frequency Load Shedding Schemes for Smart Grid Using Synchronous Phase Measurement Unit

  • Yang, D.Y. (School of Electrical & Electronic Engineering, North China Electric Power University) ;
  • Cai, G.W. (School of Electrical Engineering, Northeast Dianli University) ;
  • Jiang, Y.T. (School of Electrical Engineering, Northeast Dianli University) ;
  • Liu, C. (School of Electrical & Electronic Engineering, North China Electric Power University)
  • 투고 : 2012.07.10
  • 심사 : 2012.12.04
  • 발행 : 2013.05.01

초록

Under frequency load shedding (UFLS) is an effective way to prevent system blackout after a serious disturbance occurs in a power system. A novel centralized adaptive under frequency load shedding (AUFLS) scheme using the synchronous phase measurement unit (PMU) is proposed in this paper. Two main stages are consisted of in the developed technique. In the first stage, the active power deficit is estimated by using the simplest expression of the generator swing equation and static load model since the frequency, voltages and their rate of change can be obtained by means of measurements in real-time from various devices such as phase measurement units. In the second stage, the UFLS schemes are adapted to the estimated magnitude based on the presented model. The effectiveness of the proposed AUFLS scheme is investigated simulating different disturbance in IEEE 10-generator 39-bus New England test system.

키워드

참고문헌

  1. P. Kundur, Power system stability and control: Englewood Cliffs, NJ: McGraw-Hill, 1994.
  2. Tamronglak S., Horow S.H., Anatomy of power system blackouts: preventive relaying strategies, IEEE Trans. Power Delivery, Vol. PS-11, No. 3, pp. 708-715, June 1996.
  3. U.S. Canada Power System Outage Task Force. Final Report on the August 14, 2003 Blackout in the United States and Canada: causes and Recommendation, [EB/OL]. https://reports.energy.gov/, 2004, 04.
  4. Corsi S., Sabelli C., General blackout in Italy, Sunday September 28, 2003, h. 03:28:00, IEEE Power Engineering Society General Meeting, USA, June 2004.
  5. Y. Halevi and D. Kottick, Optimization of load shedding system, IEEE Trans. Energy Convers, Vol. 8, pp. 207-213, Jun.1993. https://doi.org/10.1109/60.222706
  6. R.M. Maliszewski, R.D. Dunlap and G.L. Wilson, Frequency Actuated Load Shedding and Restoration. Part I, Philosophy, IEEE Trans. Power Systems, Vol.PAS-90, pp.1452-1460, 1971. https://doi.org/10.1109/TPAS.1971.293129
  7. B. Delfino, S. Massucco, A. Morini, P. Scalera, and F. Silvesto, Implementation and comparison of different under frequency load shedding schemes, Proc. IEEE Power Engineering Society Summer meeting, Vol.1, 2001.
  8. Valverde G., Deyu Cai, Regulski P., Wide-Area Monitoring, Protection, and Control of Future Electric Power Networks, Proc IEEE, Vol. 99, No. 1, pp. 80- 92, Jan. 2011. https://doi.org/10.1109/JPROC.2010.2060450
  9. R Sangwook Han, Byongjun Lee, Sangtae Kim, Real Time Wide Area Voltage Stability Index in the Korean Metropolitan Area, Journal of Electrical Engineering & Technology, Vol. 4, No. 4, pp. 451-456, June 2009. https://doi.org/10.5370/JEET.2009.4.4.451
  10. J. De La Ree, V. Centeno, J. S. Thorp, and A. G. Phadke. Synchronized phasor measurement applications in power systems, IEEE Trans. Smart Grid, Vol. 1, No. 1, pp. 20-27, Jan. 2010. https://doi.org/10.1109/TSG.2010.2044815
  11. V. V. Terzija, Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation, IEEE Trans. on Power Systems, Vol. 21, No. 3, pp. 20-27, Aug. 2006.
  12. H. Seyedi, M. Sanaye-Pasand, New centralized adaptive load-shedding algorithms to mitigate power system blackouts, IET Generation, Transmission & Distribution, Vol. 3, No. 1, pp. 99-114, June. 2008.
  13. Rudez. U., Mihalic. R., Monitoring the First Frequency Derivative to Improve Adaptive Under frequency Load-Shedding Schemes, IEEE Trans. Power System, Vol. 2, No. 2, pp. 839-846, May 2011.
  14. Mahdi El Arini, Optimal Dynamic Load Shedding Policy for Generation Load Imbalances Including Characteristic of Loads, International Journal of Energy Research, Vol. 23, No. 1, pp.79-89, Jan. 1999. https://doi.org/10.1002/(SICI)1099-114X(199901)23:1<79::AID-ER469>3.0.CO;2-U
  15. Soo-Hyoung Lee, Seo-Eun Son, Sung-Moo Lee, Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data, Journal of Electrical Engineering & Technology, Vol. 7, No. 3, pp. 304-311, June 2012. https://doi.org/10.5370/JEET.2012.7.3.304
  16. P. M. Anderson, and M. Mirheydar, A Low-Order System Frequency Response Model, IEEE Trans. on Power Systems, Vol. 5, No. 3, pp. 720-729, Aug. 1990. http://psdyn.ece.wisc.edu/IEEE_benchmarks/. https://doi.org/10.1109/59.65898

피인용 문헌

  1. A method for the design of UFLS schemes of regional power system using improved frequency response model vol.27, pp.9, 2017, https://doi.org/10.1002/etep.2365
  2. Intelligent Under Frequency and Under Voltage Load Shedding Method Based on the Active Participation of Smart Appliances vol.8, pp.1, 2017, https://doi.org/10.1109/TSG.2016.2582902