DOI QR코드

DOI QR Code

Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy

코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가

  • Kim, Jae-Hong (Department of health science specialized in Dental Lab. Science & Engineering, Graduate school, Korea University) ;
  • Kim, Won-Soo (Department of Dental Laboratory Technology, Daejeon Health College) ;
  • Kim, Ki-Baek (Department of health science specialized in Dental Lab. Science & Engineering, Graduate school, Korea University)
  • 김재홍 (고려대학교 일반대학원 보건과학과 치의기공전공) ;
  • 김원수 (대전보건대학 치기공학과) ;
  • 김기백 (고려대학교 일반대학원 보건과학과 치의기공전공)
  • Received : 2012.10.15
  • Accepted : 2013.04.09
  • Published : 2013.04.30

Abstract

Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

Keywords

References

  1. Kim YS, Jun BH. A study of comparative the mastication capability and life quality of elderly people using dentures or implants. J Korean Soc Dent Hyg 2011; 11(5): 629-636.
  2. Park EM, Yu SY, Jang JH. The effect of satisfaction of dental esthetics on life quality related to oral health(OHIP-14). J Korean Soc Dent Hyg 2011; 11(6): 863-870.
  3. Petteno D, Schierano G, Bassi F, Bresciano ME, Carossa S. Comparison of marginal fit of 3 different metal-ceramic systems: an in vitro study. Int J Prosthodont 2000; 13(5): 405-408.
  4. Rosenstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 4th ed. St. Louis:Mosby. 2006, pp.606-608.
  5. Anusavice KJ. Phillips'science of dental materials. 11th ed. Philadelphia:W.B. Saunders. 2003, pp.621-654.
  6. Pierce LH, Goodkind RJ. A status report of possible risks of base metal alloys and their components. J Prosthet Dent 1989; 62(2): 234-238. https://doi.org/10.1016/0022-3913(89)90320-X
  7. Wassell RW, Walls AWG, Steele JG. Crowns and extra-coronal restorations: materials selection. Br Dent J 2002; 192(4): 199-211. https://doi.org/10.1038/sj.bdj.4801334
  8. Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconium -oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont 2008; 17(8): 621-626. https://doi.org/10.1111/j.1532-849X.2008.00366.x
  9. Jahangiri L, Wahlers C, Hittelman E, Matheson P. Assessment of sensitivity and specificity of clinical evaluation of cast restoration marginal accuracy compared to stereomicroscopy. J Prosthet Dent 2005; 93(2): 138-142. https://doi.org/10.1016/j.prosdent.2004.11.007
  10. Mejia R, Tobon SM. Marginal fit of metal ceramic restorations subjected to a standardized postsoldering technique. J Prosthet Dent 2000; 83(5): 535-539. https://doi.org/10.1016/S0022-3913(00)70011-4
  11. Limkangwalmongkol P, Chiche GJ, Blatz MB. Precision of fit of two margin designs for metal-ceramic crowns. J Prosthodont 2007; 16(4): 233-237. https://doi.org/10.1111/j.1532-849X.2007.00186.x
  12. Foster LV. Failed conventional bridge work from general dental practice: clinical aspects and treatment needs of 142 cases. Br Dent J 1990; 168(5): 199-201. https://doi.org/10.1038/sj.bdj.4807133
  13. Tjan AH, Li T, Logan GI, Baum L. Marginal accuracy of complete crowns made from alternative casting alloys. J Prosthet Dent 1991; 66(2): 157-164. https://doi.org/10.1016/S0022-3913(05)80041-1
  14. Soriani NC, Leal MB, Paulino SM, Pagnano VO, Bezzon OL. Effect of the use of die spacer on the marginal fit of copings cast in Ni-Cr, Ni-Cr-Be and commercially pure titanium. Braz Dent J 2007; 18(3): 225-230.
  15. Campbell SD, Pelletier L. Thermal cycling distortion of metal ceramics: part I-metal collar width. J Prosthet Dent 1992; 67(5): 603-608. https://doi.org/10.1016/0022-3913(92)90155-4
  16. Fonseca JC, Henriques GE, Sobrinho LC, de Goes MF. Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminium -vanadium copings. Dent Mater 2003; 19(7): 686-691. https://doi.org/10.1016/S0109-5641(03)00014-9
  17. Lakhani SA, Ercoli C, Moss ME, Graser GN, Tallents RH. Influence of cold working and thermal treatment on the fit of implant supported metal ceramic fixed partial dentures. J Prosthet Dent 2002; 88(2): 159-169. https://doi.org/10.1067/mpr.2002.127592
  18. Hasanreisoglu U, Berksun S, Aras K, Arslan I. An analysis of maxillary anterior teeth: facial and dental proportions. J Prosthet Dent 2005; 94(6): 530-538. https://doi.org/10.1016/j.prosdent.2005.10.007
  19. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62(4): 405-408. https://doi.org/10.1016/0022-3913(89)90170-4
  20. Reich S, Kappe K, Teschner H, Schmitt J. Clinical fit of fourunit zirconia posterior fixed dental prostheses. Eur J Oral Sci 2008; 116(6): 579-584. https://doi.org/10.1111/j.1600-0722.2008.00580.x
  21. Wettstein F, Sailer I, Roos M, Hammerle CHF. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008; 116(3): 272-279. https://doi.org/10.1111/j.1600-0722.2008.00527.x
  22. Harris IR, Wickens JL. A comparison of the fit of sparkeroded titanium copings and cast gold alloy copings. Int J Prosthodont 1994; 7(4): 348-355.
  23. McLean JM, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971; 131(3): 107-111. https://doi.org/10.1038/sj.bdj.4802708
  24. Fransson B, Olio G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater 1985; 1(5): 197-199. https://doi.org/10.1016/S0109-5641(85)80019-1
  25. Strating H, Pameijer C, Gildenhuys RR. Evaluation of the marginal integrity of ceramometal restorations: part I. J Prosthet Dent 1981; 46(1): 59-65. https://doi.org/10.1016/0022-3913(81)90136-0
  26. Buchanan WT, Svare CW, Turner KA. The effect of repeated firings and strength on marginal distortion in two ceramometal systems. J Prosthet Dent 1981; 45(5): 502-506. https://doi.org/10.1016/0022-3913(81)90035-4
  27. Bridger DV, Nicholls JI. Distortion of ceramometal fixed partial dentures during the firing cycle. J Prosthet Dent 1981; 45(5): 507-514. https://doi.org/10.1016/0022-3913(81)90036-6
  28. Campbell SD, Pelletier L. Thermal cycling distortion of metal ceramics: part I-metal collar width. J Prosthet Dent 1992; 67(5): 603-608. https://doi.org/10.1016/0022-3913(92)90155-4
  29. Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005; 93(4): 346-355. https://doi.org/10.1016/j.prosdent.2005.02.003
  30. Komine F, Shiratsuchi H, Kakehashi Y, Matsumura H. Influence of porcelain-firing procedures on the marginal distortion of electroformed metal-ceramic restorations. Quintessence Int 2007; 38(10): E583-E588.
  31. Prakash P, DSJ D'Souza, Manjit Kumar, M Viswambaran. Effect of firing cycle and surface finishing on the sag resistance of long-span metal ceramic framework using base metal alloys-an in vitro study. MJAFI 2012; 68(2): 142-150.

Cited by

  1. Understanding and trends of esthetic treatment in prosthodontics : IPS e.max vol.14, pp.4, 2014, https://doi.org/10.13065/jksdh.2014.14.04.447
  2. Understanding and trends of esthetic treatment in prosthodontics : part 2. Zirconia vol.14, pp.5, 2014, https://doi.org/10.13065/jksdh.2014.14.05.617
  3. 3D printing으로 제작된 금속 코어와 치과용 도재 간의 전단결합강도 평가 vol.16, pp.4, 2013, https://doi.org/10.5762/kais.2015.16.4.2585
  4. 3점 굽힘강도 시험을 통한 Lithium disilicate glass ceramic의 표면 연마 정도에 따른 강도 평가 vol.40, pp.1, 2013, https://doi.org/10.14347/kadt.2018.40.1.9