Survey Research on Thermal Situation of Office Buildings

사무소 건축물의 단열상황에 관한 조사연구

  • Received : 2012.12.18
  • Accepted : 2013.04.14
  • Published : 2013.05.30

Abstract

This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

본 논문은 1990년대~2011년 시공 중이었던 건축물의 커튼월의 단열성을 평가하기 위하여 내외 표면 온도를 측정하여 부위별 온도 차이를 분석하였다. 유리면이나 단열층이 있는 표면보다 커튼월의 프레임 (멀리온 및 트랜섬)의 온도는 동절기 외부 평면의 경우 $6^{\circ}C{\sim}10^{\circ}C$ 정도 높게 나타났다. 또한, 같은 프레임에서도 앵커유닛이 있는 부위가 다른 프레임보다 $2^{\circ}C{\sim}3^{\circ}C$ 더 높게 나타나 보다 큰 열 손실이 일어나고 있는 것으로 나타났다.

Keywords

References

  1. Choi, G. S., Jeong, Y. S., Kang, J. S., Lee, S. E., "Developemnt of In-site Evaluation Method for Building Insulation Performance Using Infra-red Camera", Journal of Architectural Institute of Korea, vol. 24, No. 1, 2004, pp.762-765. (in Korean)
  2. Choi, M. Y., Kim, W. T., "The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography", Journal Of The Korean Society For Nondestructive Testing, vol. 24, No. 5, 2004, pp.525-531. (in Korean)
  3. Kim, B. J., Kim, K. A., Park, J. M., "Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel- Curtain wall", Academic Journal of the Korea Institute of Building Construction, vol. 11, No. 1, 2011, pp.107-110. (in Korean)
  4. Kim, K. A., Kim, B. J., "Heat Loss the Case Study of Office Building", Academic Journal of the Korea Institute of Building Construction, vol. 11, No. 1, 2011, pp.51-54. (in Korean) https://doi.org/10.5345/JKIC.2011.02.1.051
  5. Kim, Y. J., "Study on the energy conservation in residential complex by insulating the fastening unit of curtain wall system", paper of masters degree, Ewha womans Univ., 2005, pp.8-32. (in Korean)
  6. Koo, S. Y., Ku, H. Y., Yeo, M. S., Kim, K. W., "Thermal Performance of Opaque Part of the Curtain walls in Buildings", Journal of Architectural Institute of Korea, vol. 28, No. 1, 2008, pp.559-562. (in Korean)
  7. Kwon. Y. C., Seo. S. Y., Kim. S. Y., "Thermal Property and Fire Resistance of Cellulose Insulation", Journal of the Korea institute for structural maintenance inspection, vol. 9, No. 3, 2005, pp.203-212. (in Korean)
  8. Lee, M. J., Lee, S. W., Yeo, M. S., Kim. G. W., "An Experimental Study on Insulation and Preventing Condensation Performance of Ventilated Curtain Wall", Academic Journal of Air-Conditioning and Refrigeration Engineering of Korea, vol. 2006, No. 6, 2006, pp.1081-1086. (in Korean)
  9. Lee, M. W,, Lee, S. W., Yeo, M. S., Song, S. Y., Kim, G. W., "A Study on the Construction Detail of Joints for Stone Panel Curtain Wall Considering the Prevention of Condensation", Journal of Architectural Institute of Korea, vol. 22, No. 4, 2006, Apr, pp.277-284. (in Korean)
  10. Lee, T. C., Yoon, S. H., "Review on Radiation Temperature Distribution of a Multipurpose High-rise Building by Infrared Rays Camera", Journal of Asian Architecture and Building Engineering, vol. 2012, No. 3, 2012, pp.77-80. (in Korean)
  11. Lee, Y. G., Lee, S. H., Lee, S. Y., "Effect of Components Assembly and Sizing on the Thermal Performance of Windows", Journal of Architectural Institute of Korea, vol. 22, No. 7, 2006, pp.215-222. (in Korean)
  12. Song, S. Y., Kang, K. Y., Yeo, M. S., Kim, G. W., "Influence of Damaged Inside Finish Material for Insulation on the Condensation and Efficient Finish Material to Prevent Interstitial Condensation in Curtain Wall System", Journal of Architectural Institute of Korea, vol. 22, No. 8, 2006, pp.241-249. (in Korean)
  13. Song, S. Y., Koo, B. K., Seok, H. T., "Performance Evaluation of the Various Insulation Schemes for Fastening Unit in Aluminum Curtain Wall System of Residential Complex", Journal of Architectural Institute of Korea, vol. 26, No. 1, 2006, pp.609-612. (in Korean)