DOI QR코드

DOI QR Code

The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong (Department of Dentistry, Ajou University School of Medicine) ;
  • Kim, Sung-Hun (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Han, Jung-Suk (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Yoo, Seung-Hyun (Department of Mechanical Engineering, College of Engineering, Ajou University) ;
  • Jeong, Se-Chul (Department of Mechanical Engineering, College of Engineering, Ajou University) ;
  • Lee, Jai-Bong (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University) ;
  • Yeo, In-Sung (Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University)
  • Received : 2012.12.20
  • Accepted : 2013.05.12
  • Published : 2013.05.31

Abstract

PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

Keywords

References

  1. Triwatana P, Nagaviroj N, Tulapornchai C. Clinical performance and failures of zirconia-based fixed partial dentures: a review literature. J Adv Prosthodont 2012;4:76-83. https://doi.org/10.4047/jap.2012.4.2.76
  2. Imanishi A, Nakamura T, Ohyama T, Nakamura T. 3-D Finite element analysis of all-ceramic posterior crowns. J Oral Rehabil 2003;30:818-822. https://doi.org/10.1046/j.1365-2842.2003.01123.x
  3. Fradeani M, Aquilano A. Clinical experience with Empress crowns. Int J Prosthodont 1997;10:241-247.
  4. Fradeani M, D'Amelio M, Redemagni M, Corrado M. Fiveyear follow-up with Procera all-ceramic crowns. Quintessence Int 2005;36:105-113.
  5. Fradeani M, Redemagni M. An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study. Quintessence Int 2002;33:503-510.
  6. Malament KA, Socransky SS. Survival of Dicor glass-ceramic dental restorations over 14 years. Part II: effect of thickness of Dicor material and design of tooth preparation. J Prosthet Dent 1999;81:662-667. https://doi.org/10.1016/S0022-3913(99)70104-6
  7. Malament KA, Socransky SS. Survival of Dicor glass-ceramic dental restorations over 16 years. Part III: effect of luting agent and tooth or tooth-substitute core structure. J Prosthet Dent 2001;86:511-519. https://doi.org/10.1067/mpr.2001.119415
  8. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007;20:383-388.
  9. Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P, Franz Hammerle CH. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 2006;37:685-693.
  10. Sailer I, Gottnerb J, Kanelb S, Hammerle CH. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 2009;22:553-560.
  11. Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 2006;96:237-244. https://doi.org/10.1016/j.prosdent.2006.08.010
  12. Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 2008;21:223-227.
  13. Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: fouryear clinical results. Int J Prosthodont 2010;23:141-148.
  14. Schmitt J, Holst S, Wichmann M, Reich S, Gollner M, Hamel J. Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up. Int J Prosthodont 2009;22:597-603.
  15. Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O. Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 2009;36:610-615. https://doi.org/10.1111/j.1365-2842.2009.01969.x
  16. Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005;32:180-187. https://doi.org/10.1111/j.1365-2842.2004.01437.x
  17. Tsumita M, Kokubo Y, Ohkubo C, Sakurai S, Fukushima S. Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study. J Prosthodont Res 2010;54: 102-105. https://doi.org/10.1016/j.jpor.2010.01.001
  18. Wakabayashi N, Ona M, Suzuki T, Igarashi Y. Nonlinear finite element analyses: advances and challenges in dental applications. J Dent 2008;36:463-471. https://doi.org/10.1016/j.jdent.2008.03.010
  19. Eraslan O, Sevimay M, Usumez A, Eskitascioglu G. Effects of cantilever design and material on stress distribution in fixed partial dentures-a finite element analysis. J Oral Rehabil 2005;32:273-278. https://doi.org/10.1111/j.1365-2842.2004.01429.x
  20. Rafferty BT, Janal MN, Zavanelli RA, Silva NR, Rekow ED, Thompson VP, Coelho PG. Design features of a three-dimensional molar crown and related maximum principal stress. A finite element model study. Dent Mater 2010;26: 156-163. https://doi.org/10.1016/j.dental.2009.09.009
  21. Ausiello P, Apicella A, Davidson CL, Rengo S. 3D-finite element analyses of cusp movements in a human upper premolar, restored with adhesive resin-based composites. J Biomech 2001;34:1269-1277. https://doi.org/10.1016/S0021-9290(01)00098-7
  22. Coelho PG, Silva NR, Thompson VP, Rekow D, Zhang G. Effect of proximal wall height on all-ceramic crown core stress distribution: a finite element analysis study. Int J Prosthodont 2009;22:78-86.
  23. Ohlmann B, Marienburg K, Gabbert O, Hassel A, Gilde H, Rammelsberg P. Fracture-load values of all-ceramic cantilevered FPDs with different framework designs. Int J Prosthodont 2009;22:49-52.
  24. Ulusoy M, Toksavul S. Fracture resistance of five different metal framework designs for metal-ceramic restorations. Int J Prosthodont 2002;15:571-574.
  25. Rekow ED, Harsono M, Janal M, Thompson VP, Zhang G. Factorial analysis of variables influencing stress in all-ceramic crowns. Dent Mater 2006;22:125-132. https://doi.org/10.1016/j.dental.2005.04.010
  26. Silva NR, Bonfante EA, Rafferty BT, Zavanelli RA, Rekow ED, Thompson VP, Coelho PG. Modified Y-TZP core design improves all-ceramic crown reliability. J Dent Res 2011; 90:104-108. https://doi.org/10.1177/0022034510384617
  27. Lundgren D, Laurell L. Occlusal force pattern during chewing and biting in dentitions restored with fixed bridges of cross-arch extension. I. Bilateral end abutments. J Oral Rehabil 1986;13:57-71. https://doi.org/10.1111/j.1365-2842.1986.tb01556.x
  28. Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB. Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 1981;46:443-449. https://doi.org/10.1016/0022-3913(81)90455-8
  29. Magne P, Belser UC. Rationalization of shape and related stress distribution in posterior teeth: a finite element study using nonlinear contact analysis. Int J Periodontics Restorative Dent 2002;22:425-433.
  30. Morikawa A. Investigation of occlusal force on lower first molar in function. Kokubyo Gakkai Zasshi 1994;61:250-274. https://doi.org/10.5357/koubyou.61.250

Cited by

  1. Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia vol.5, pp.3, 2013, https://doi.org/10.4047/jap.2013.5.3.296
  2. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type vol.7, pp.6, 2015, https://doi.org/10.4047/jap.2015.7.6.475
  3. Effect of the amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics vol.8, pp.1, 2016, https://doi.org/10.4047/jap.2016.8.1.37
  4. Influence of Different Framework Designs on the Fracture Properties of Ceria-Stabilized Tetragonal Zirconia/Alumina-Based All-Ceramic Crowns vol.9, pp.5, 2016, https://doi.org/10.3390/ma9050339
  5. A Retrospective Study on the Incidence of Chipping of Zirconia-Based Restorations vol.587, pp.1662-9795, 2013, https://doi.org/10.4028/www.scientific.net/KEM.587.356
  6. Effect of Zirconia Core Thickness and Veneer Firing Cycle on the Biaxial Flexural Strength of Veneering Ceramic pp.1059941X, 2018, https://doi.org/10.1111/jopr.12929
  7. Comparison of stress distribution in dental crown with different cusp angles: 3D finite element analysis pp.1476-8259, 2019, https://doi.org/10.1080/10255842.2018.1549659
  8. Three-dimensional finite element analysis of a porcelain crowned tooth vol.7, pp.4, 2013, https://doi.org/10.1016/j.bjbas.2018.04.002
  9. 리튬 디실리케이트-지르코니아 이중도재관과 단일구조 지르코니아로 제작된 구치부 고정성 임플란트 지지 보철물의 전향적 임상연구: 24개월 추적관찰 vol.57, pp.2, 2013, https://doi.org/10.4047/jkap.2019.57.2.134
  10. Effect of time period on biaxial strength for different Y‐TZP veneering porcelains vol.32, pp.5, 2013, https://doi.org/10.1111/jerd.12607
  11. Comparison of stress analysis for dental crown (FPD) for various materials vol.45, pp.p9, 2013, https://doi.org/10.1016/j.matpr.2020.12.838